NextSDS Logo
Safety Data Sheet EN

PureLink Genomic Lysis/Binding Buffer

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PureLink Genomic Lysis/Binding Buffer
Product Code
467181
Chemical Name
Not Applicable

Regulatory Identifiers

CAS Number
N/A
REACH No.
No registration number is given yet for this substance / substances in this mixture since the annual import quantity is less than one tonnage per annum or the transition period for its registration according to Article 23 of REACH has not yet expired.
UFI Code
Not Applicable

Identified Uses

For research use only. Not for use in diagnostic procedures. SU22 - Professional uses: Public domain (administration, education, entertainment, services, craftsmen), PROC15 - Use as laboratory reagent, PC21 - Laboratory chemicals, SU24 - Scientific research and development

Uses advised against

Not for consumer use.

Manufacturers & Suppliers

L

LIFE TECHNOLOGIES EUROPE BV

manufacturer

KWARTSWEG 2, 2665 NN BLEISWIJK, NETHERLANDS

31-(0)180 392 400

L

Life Technologies Limited

manufacturer

3 Fountain Drive, Inchinnan Business Park, Paisley, PA4 9RF, UK

+44 (0)141 814 6100

Emergency Contacts

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

CHEMTREC

1-703-741-5970

CHEMTREC Ireland (Dublin)

+(353)-19014670

EN, GA

CHEMTREC UK (London)

+(44)-870-8200418

EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Acute Tox. Cat. 4
Acute Tox. Cat. 4
Skin Irrit. Cat. 2
Eye Irrit. Cat. 2A

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H302 Harmful if swallowed
H315 Causes skin irritation
H319 Causes serious eye irritation
H332 Harmful if inhaled

Precautionary Statements

P261 Avoid breathing dust/fume/gas/mist/vapours/spray
P264 Wash hands thoroughly after handling
P270 Do not eat, drink or smoke when using this product
P271 Use only outdoors or in a well-ventilated area
P280 Wear protective gloves/protective clothing/eye protection/face protection
P301 + P312 IF SWALLOWED: Call a POISON CENTER or doctor/physician if you feel unwell
P302 + P352 IF ON SKIN: Wash with plenty of soap and water
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing
P312 Call a POISON CENTER or doctor/physician if you feel unwell
P330 Rinse mouth
P332 + P313 If skin irritation occurs: Get medical advice/attention
P337 + P313 If eye irritation persists: Get medical advice/attention
P501 Dispose of contents/ container to an approved waste disposal plant

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Guanidine hydrochloride EC: 200-002-3 50-01-1 35 - 45% Yes
Poly(oxy-1,2-ethanediyl), .alpha.-[4-(1,1,3,3-tetramethylbutyl)phenyl]-.omega.-hydroxy- EC: 618-344-0 9002-93-1 0.9% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. If symptoms persist, call a doctor.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Immediate medical attention is required.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Immediate medical attention is required.

Ingestion

Never give anything by mouth to an unconscious person. Do not induce vomiting without medical advice. Get medical attention if symptoms occur.

Immediate Medical Attention

Immediate medical attention is required for skin and eye contact. Call a POISON CENTER or doctor/physician if you feel unwell (if swallowed or inhaled). Get medical advice/attention if symptoms occur.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray. Carbon dioxide (CO₂). Foam. Dry chemical.

Specific hazards

No data

Firefighter Protection

Wear self-contained breathing apparatus and protective suit.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Prevent product from entering drains. Do not allow material to contaminate ground water system.

Cleanup methods

Soak up with inert absorbent material.

Materials: inert absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Always wear recommended Personal Protective Equipment. Do not get in eyes, on skin, or on clothing. Do not ingest. Avoid breathing vapours or mists. If during normal use the material presents a respiratory hazard, use adequate ventilation and/or wear appropriate respirator. Use personal protective equipment as required. See section 8 for more information.

Storage

Keep in a dry, cool and well-ventilated place. Keep in properly labelled containers. Store in accordance with local regulations.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feedingstuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and immediately after handling the product.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Relative Density
---
Partition Coefficient
---
Odor
---
Properties Status
---
Solubility
---
Cloud Point
---
Density
---
Melting Point
---
Physical State Data
liquid
Relative Evaporation Rate
---
Form
---
Kinematic Viscosity
---
Voc Content
---
Crystallisation Point
---
Flammability
---
Odor Threshold
---
Vapor Density
---
Colour Intensity
---
Evaporation Rate
---
Solubility In Fat
---
Softening Point
---
State Under Standard Conditions
---
Metal Corrosion
---
Boiling Point
---
Lower Explosive Limit
---
Colour
---
Explosive Limits
---
Auto Ignition Temperature
---
Upper Explosive Limit
---
Appearance
---
Solubility In Water
---
Flash Point
---
Freezing Point
---
Dynamic Viscosity
---
Bulk Density
---
Solidification Point
---
Ph
6-8
Molecular Weight
---
Vapor Pressure
---
Decomposition Temperature
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

None known.

Hazardous reactions

Hazardous reaction has not been reported.

Avoid

Contact with acids or bleach liberates toxic gases. DO NOT ADD acids or bleach to any liquid wastes containing this product.

Incompatible

No dangerous reaction known under conditions of normal use.

Decomposition

No known hazardous decomposition products.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PureLink Genomic Lysis/Binding Buffer?

The signal word is warning.

What is the physical form of PureLink Genomic Lysis/Binding Buffer?

PureLink Genomic Lysis/Binding Buffer is a liquid .

What is PureLink Genomic Lysis/Binding Buffer used for?

For research use only. Not for use in diagnostic procedures. SU22 - Professional uses: Public domain (administration, education, entertainment, services, craftsmen), PROC15 - Use as laboratory reagent, PC21 - Laboratory chemicals, SU24 - Scientific research and development

What are the hazard statements for PureLink Genomic Lysis/Binding Buffer?

This substance has 4 hazard statements:

  • H302: Harmful if swallowed
  • H315: Causes skin irritation
  • H319: Causes serious eye irritation
  • H332: Harmful if inhaled