NextSDS Logo
Safety Data Sheet EN

Tuning Mix 2

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Tuning Mix 2
Product Code
96016
Synonyms
MassTox® Drugs of Abuse Testing in urine

Regulatory Identifiers

CAS Number
N/A

Identified Uses

In vitro diagnostics, PC21 Laboratory chemicals, PROC15 Use as laboratory reagent

Manufacturers & Suppliers

Chromsystems Instruments & Chemicals GmbH logo

Chromsystems Instruments & Chemicals GmbH

manufacturer

Am Haag 12, 82166 Gräfelfing, Germany

+49 89 18930-0

http://www.chromsystems.com

Emergency Contacts

Emergency poison number

+49 89 19240

DE, EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Acute Tox. Cat. 4 H302
Acute Tox. Cat. 4 H312
Acute Tox. Cat. 4 H332
Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H225 Highly flammable liquid and vapour.
H302 + H312 + H332 Harmful if swallowed, in contact with skin or if inhaled.
H319 Causes serious eye irritation.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P241 Use explosion-proof [electrical/ventilating/lighting] equipment.
P243 Take action to prevent static discharges.
P280 Wear protective gloves/protective clothing/eye protection/face protection.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
acetonitrile EC: 200-835-2 75-05-8 50 - 100% Yes
methanol EC: 200-659-6 67-56-1 2.5% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. Provide oxygen treatment if affected person has difficulty breathing. In case of irregular breathing or respiratory arrest provide artificial respiration. Use a respiratory bag or breathing device. Seek medical treatment.

Symptoms: Breathing difficulty, Headache, Spasms, Dizziness, Unconsciousness, Nausea

Skin contact

Immediately rinse with plenty of water. Seek medical treatment.

Symptoms: Irritation

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Symptoms: Irritation

Ingestion

Rinse out mouth and then drink plenty of water. Seek medical treatment.

Symptoms: Nausea

Immediate Medical Attention

Seek medical treatment. Symptoms of poisoning may even occur after several hours; therefore medical observation for at least 48 hours after the accident.

Medical Treatment

Seek medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Fire-extinguishing powder, Carbon dioxide, Foam

Specific hazards

Nitrogen oxides (NOx), Hydrogen cyanide (HCN)

Instructions

Cool endangered receptacles with water spray.

Firefighter Protection

Wear self-contained respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ensure adequate ventilation. Wear protective equipment. Keep unprotected persons away. Keep away from ignition sources.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, universal binders

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace. Ensure good interior ventilation, especially at floor level. (Fumes are heavier than air). Keep receptacles tightly sealed.

Storage

Store only in the original receptacle. Store receptacle in a well ventilated area. Store below -18°C. Keep container tightly sealed. Protect from heat and direct sunlight.

Fire prevention

Keep ignition sources away - Do not smoke.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see section 7.

Hands

Protective gloves. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374. For the permanent contact gloves made of the following materials are suitable: Butyl rubber, BR, Recommended thickness of the material: ≥ 0.7 mm, Penetration time: > 480 min. As protection from splashes gloves made of the following materials are suitable: Polychloroprene, Recommended thickness of the material: ≥ 0.65 mm, Penetration time: > 30 min.

Eyes

Tightly sealed goggles

Respiratory

Use suitable respiratory protective device when high concentrations are present. Filter A

Skin/Body

Light weight protective clothing

Environmental

Do not empty into drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Flash Point
< 23 °C
Vapor Density
Not determined.
Ph
Not determined.
Molecular Weight
---
Lower Explosive Limit
> 3 Vol %
Decomposition Temperature
Not determined.
Explosive Limits
---
Relative Density
Not determined.
Freezing Point
Undetermined.
Appearance
---
Upper Explosive Limit
< 20 Vol %
Auto Ignition Temperature
Product is not selfigniting.
Partition Coefficient
Not determined.
Metal Corrosion
Void.
Form
Fluid
Colour Intensity
---
State Under Standard Conditions
---
Solidification Point
---
Voc Content
---
Bulk Density
---
Melting Point
Undetermined.
Crystallisation Point
---
Density
Not determined.
Solubility
---
Physical State Data
liquid
Odor
Characteristic
Kinematic Viscosity
Not determined.
Vapor Pressure
Not determined.
Solubility In Fat
---
Colour
Colourless
Boiling Point
> 35 °C
Flammability
Not applicable.
Solubility In Water
Fully miscible.
Softening Point
---
Cloud Point
---
Dynamic Viscosity
Not determined.
Evaporation Rate
Not determined.
Relative Evaporation Rate
---
Properties Status
---
Odor Threshold
Not determined.
Physical State
Fluid
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

Fumes may form an explosive mixture with air.

Hazardous reactions

Forms explosive gas mixture with air. Reacts with acids. Reacts with oxidising agents.

Avoid

Heating.

Incompatible

Various plastics, rubber.

Decomposition

Nitrogen oxides (NOx), Hydrogen cyanide (prussic acid)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Product residues are to be disposed of in compliance with Directive 2008/98/EC on Waste and national and local requirements, e.g. in a suitable incineration plant.

Disposal

Leave chemicals in original containers. Transfer small quantities to approved transport containers. Protect collection receptacles and containers from access by unauthorized parties. Must not be disposed together with domestic waste. Do not circulate into the main water supply.

Waste Codes

16 05 06* laboratory chemicals, consisting of or containing hazardous substances, including mixtures of laboratory chemicals EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1648
Shipping Name
ACETONITRILE solution
Transport Class
3
Packing Group
II
ADR

Warning: Flammable liquids.

IMDG

Warning: Flammable liquids.

IATA

Warning: Flammable liquids.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

No further relevant information available.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Tuning Mix 2 known by?

Tuning Mix 2 is also known as: MassTox® Drugs of Abuse Testing in urine

What is the hazard signal word for Tuning Mix 2?

The signal word is danger.

What is the physical form of Tuning Mix 2?

Tuning Mix 2 is a fluid with colourless color. It has characteristic odor.

What is Tuning Mix 2 used for?

In vitro diagnostics, PC21 Laboratory chemicals, PROC15 Use as laboratory reagent

What are the hazard statements for Tuning Mix 2?

This substance has 3 hazard statements:

  • H225: Highly flammable liquid and vapour.
  • H302 + H312 + H332: Harmful if swallowed, in contact with skin or if inhaled.
  • H319: Causes serious eye irritation.

What is the melting point of Tuning Mix 2?

The melting point is Undetermined. and the boiling point is > 35 °C.