NextSDS Logo
Safety Data Sheet EN

Tuning Mix 3

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Tuning Mix 3
Product Code
96017
Synonyms
MassTox® Drugs of Abuse Testing in urine

Regulatory Identifiers

CAS Number
N/A

Identified Uses

In vitro diagnostics, PC21 Laboratory chemicals, PROC15 Use as laboratory reagent

Manufacturers & Suppliers

Chromsystems Instruments & Chemicals GmbH logo

Chromsystems Instruments & Chemicals GmbH

manufacturer

Am Haag 12, 82166 Gräfelfing, Germany

+49 89 18930-0

http://www.chromsystems.com

Emergency Contacts

Emergency poison number

+49 89 19240

DE, EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Acute Tox. Cat. 4 H302
Acute Tox. Cat. 4 H312
Acute Tox. Cat. 4 H332
Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H225 Highly flammable liquid and vapour.
H302 + H312 + H332 Harmful if swallowed, in contact with skin or if inhaled.
H319 Causes serious eye irritation.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P241 Use explosion-proof [electrical/ventilating/lighting] equipment.
P243 Take action to prevent static discharges.
P280 Wear protective gloves/protective clothing/eye protection/face protection.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
acetonitrile EC: 200-835-2 75-05-8 50 - 100% Yes
methanol EC: 200-659-6 67-56-1 2.5% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. Provide oxygen treatment if affected person has difficulty breathing. In case of irregular breathing or respiratory arrest provide artificial respiration. Use a respiratory bag or breathing device. Seek medical treatment.

Symptoms: Breathing difficulty, Headache, Spasms, Dizziness, Unconsciousness, Nausea, dyspnoea.

Skin contact

Immediately rinse with plenty of water. Seek medical treatment.

Symptoms: Irritation.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Symptoms: Irritation.

Ingestion

Rinse out mouth and then drink plenty of water. Seek medical treatment.

Symptoms: Nausea, Unconsciousness.

Immediate Medical Attention

Seek medical treatment.

Medical Treatment

Seek medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Fire-extinguishing powder, Carbon dioxide, Foam

Specific hazards

In case of fire, the following can be released: Nitrogen oxides (NOx), Hydrogen cyanide (HCN)

Instructions

Cool endangered receptacles with water spray.

Firefighter Protection

Wear self-contained respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ensure adequate ventilation. Wear protective equipment. Keep unprotected persons away. Keep away from ignition sources.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, universal binders

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace. Ensure good interior ventilation, especially at floor level. (Fumes are heavier than air). Keep receptacles tightly sealed.

Storage

Store only in the original receptacle. Store receptacle in a well ventilated area. Store below -18°C. Keep container tightly sealed. Protect from heat and direct sunlight.

Fire prevention

Keep ignition sources away - Do not smoke. Protect against electrostatic charges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see section 7.

Hands

Protective gloves. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374. For the permanent contact gloves made of the following materials are suitable: Butyl rubber, BR, Recommended thickness of the material: ≥ 0.7 mm, Penetration time: > 480 min. As protection from splashes gloves made of the following materials are suitable: Polychloroprene, Recommended thickness of the material: ≥ 0.65 mm, Penetration time: > 30 min.

Eyes

Tightly sealed goggles

Respiratory

Use suitable respiratory protective device when high concentrations are present. Filter A

Skin/Body

Light weight protective clothing

Environmental

Do not empty into drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Fluid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colourless
Colour Intensity
---
Form
Fluid
Odor
Characteristic
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Undetermined.
Boiling Point
> 35 °C
Flash Point
< 23 °C
Freezing Point
Undetermined.
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
Not determined.
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
Not determined.
Flammability
Not applicable.
Upper Explosive Limit
< 20 Vol %
Lower Explosive Limit
> 3 Vol %
Explosive Limits
---
Auto Ignition Temperature
Product is not selfigniting.
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Fully miscible.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
Void.
Dynamic Viscosity
Not determined.
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

Fumes may form an explosive mixture with air.

Hazardous reactions

Forms explosive gas mixture with air. Reacts with acids. Reacts with oxidising agents.

Avoid

Heating.

Incompatible

Various plastics, rubber.

Decomposition

Nitrogen oxides (NOx) Hydrogen cyanide (prussic acid)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Aquatic toxicity: The particulars refer to the pure substances and are taken from the supplier safety data sheet. 75-05-8 acetonitrile | IC5/8 d | 7300 mg/l (Scenedesmus quadricauda) (IUCLID) | | --- | --- | | EC5/16 h | 680 mg/l (Pseudomonas putida) (IUCLID) | | NOEC/72 h | > 1000 mg/l (Pseudokirchneriella subcapitata) (OECD 201) | | NOEC/21 d | 960 mg/l (Daphnia magna) (OECD 202) | | LC50/96 h | > 100 mg/l (Oryzias latipes) (OECD 203) | | | 1640 mg/l (Pimephales promelas) (IUCLID) | | EC50/48 h | > 1000 mg/l (Daphnia magna) (OECD 202) | | EC50/72 h | > 1000 mg/l (Pseudokirchneriella subcapitata) (OECD 201) | 67-56-1 methanol | IC5/8 d | 8000 mg/l (Scenedesmus quadricauda) (IUCLID) | | --- | --- | | EC5/16 h | 6600 mg/l (Pseudomonas fluorescens) (IUCLID) | | NOEC/200 h | 7900 mg/l (Oryzias latipes) | | LC50/96 h | 15400 mg/l (Lepomis macrochirus) (ECOTOX Database) | | EC5/72 h | > 10000 mg/l (Entosiphon sulcatum) | | EC50/48 h | > 10000 mg/l (Daphnia magna) (IUCLID) | | EC50/96 h | ~ 22000 mg/l (Pseudokirchneriella subcapitata) |

12.2 Persistence and degradability

Acetonitril (particulars from supplier safety data sheet): Biodegradability: 70 %; 21 d OECD 310 Easily biodegradable.

12.3 Bioaccumulative potential

Acetonitril (particulars from supplier safety data sheet): Partition coefficient: n-octanol/water log Pow: -0,34 (IUCLID) Bioaccumulation not expected.

Bioaccumulation not expected.

12.4 Mobility in soil

Acetonitril (particulars from supplier safety data sheet): Distribution among environmental compartments - Adsorption/Soil log Koc: 1.21 Mobile in soils

12.5 Results of PBT and vPvB assessment

Does not meet the criteria for PBT or vPvB pursuant to Commission Regulation (EU) No. 1907/2006, Annex XIII. - PBT: Not applicable. - vPvB: Not applicable.

The substance does not meet the criteria for PBT or vPvB classification.

12.6 Endocrine disrupting properties

The product does not contain substances with endocrine disrupting properties.

The product does not contain substances with endocrine disrupting properties.

12.7 Other adverse effects

Additional ecological information: General notes: Water hazard class 2 (German Regulation) (Self-assessment): hazardous for water. Do not allow product to reach ground water, water course or sewage system. Danger to drinking water if even small quantities leak into the ground.

The product is classified as hazardous for water (Water hazard class 2, German Regulation). It should not be allowed to reach groundwater, watercourses, or sewage systems due to the risk of contaminating drinking water.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

e.g. in a suitable incineration plant.

Disposal

Product residues are to be disposed of in compliance with Directive 2008/98/EC on Waste and national and local requirements. Leave chemicals in original containers. Transfer small quantities to approved transport containers. Protect collection receptacles and containers from access by unauthorized parties. Must not be disposed together with domestic waste. Do not circulate into the main water supply.

Waste Codes

16 05 06* laboratory chemicals, consisting of or containing hazardous substances, including mixtures of laboratory chemicals EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1648
Shipping Name
ACETONITRILE solution
Transport Class
3
Packing Group
II
ADR

Warning: Flammable liquids.

IMDG

Warning: Flammable liquids.

IATA

Warning: Flammable liquids.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

No further relevant information available.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Tuning Mix 3 known by?

Tuning Mix 3 is also known as: MassTox® Drugs of Abuse Testing in urine

What is the hazard signal word for Tuning Mix 3?

The signal word is danger.

What is the physical form of Tuning Mix 3?

Tuning Mix 3 is a fluid with colourless color. It has characteristic odor.

What is Tuning Mix 3 used for?

In vitro diagnostics, PC21 Laboratory chemicals, PROC15 Use as laboratory reagent

What are the hazard statements for Tuning Mix 3?

This substance has 3 hazard statements:

  • H225: Highly flammable liquid and vapour.
  • H302 + H312 + H332: Harmful if swallowed, in contact with skin or if inhaled.
  • H319: Causes serious eye irritation.

What is the melting point of Tuning Mix 3?