NextSDS Logo
Lu

Lumipulse G pTau 181 Plasma Calibrators, CAL 1, CAL 2, CAL 3, CAL 4, CAL 5

WARNING Fluid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Lumipulse G pTau 181 Plasma Calibrators, CAL 1, CAL 2, CAL 3, CAL 4, CAL 5
Product Code
59646

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Laboratory use. For product use see insert.
Uses Advised Against
Not to be used for any purpose other than those mentioned below.

Overview

Lumipulse G pTau 181 Plasma Calibrators, CAL 1, CAL 2, CAL 3, CAL 4, CAL 5 commonly used laboratory use. for product use see insert..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Skin Sens. Category 1 H317
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H317: May cause an allergic skin reaction.
  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • P273: Avoid release to the environment.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P302+P352: IF ON SKIN: Wash with plenty of soap and water.
  • P333+P313: If skin irritation or rash occurs: Get medical advice/attention.
  • P362+P364: Take off contaminated clothing and wash it before reuse.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

FUJIREBIO EUROPE N.V.

manufacturer

๐Ÿ“

Technologiepark 6, 9052 Gent, Belgium

๐ŸŒ

BE

๐Ÿ“ 

+32-9-329-19-11

Fujirebio Europe N.V.

undefined

๐Ÿ“

Technologiepark 6, 9052 Zwijnaarde, Belgium

๐ŸŒ

BE

๐Ÿ“ž

+32-9-329.13.29

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Fujirebio Europe N.V.

๐Ÿ“ž

+32-9-329-13-29

๐ŸŒ

BE

๐Ÿ•’

Mon - Fri 9:00am to 5:30pm

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
saccharose
EC: 200-334-9
57-50-1 2.5% โš ๏ธ Hazardous
Tris-(hydroxymthyl) aminomthane
EC: 201-064-4
77-86-1 2.5% โš ๏ธ Hazardous
2-methyl-2H-isothiazool3-on
EC: 220-239-6
2682-20-4 0.0015-0.025% โš ๏ธ Hazardous
Reaction mass of: 5-chloro-2- methyl-4-isothiazolin-3-one [EC no. 247-500-7] and 2-methyl-2H- isothiazol-3-one [EC no. 220-239- 6] (3:1) 55965-84-9 0.0025-0.025% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of complaints.

๐Ÿ–๏ธ Skin Contact

Immediately wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting; call for medical help immediately.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š Bulk Density
Not available
๐Ÿ“Š Auto Ignition Temperature
Not determined.
๐Ÿ“Š Freezing Point
Undetermined.
๐Ÿ”ฅ Flash Point
Not applicable.
Critical Property
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ“Š Metal Corrosion
void
๐Ÿ’จ Boiling Point
Undetermined.
Critical Property
๐Ÿ“Š Cloud Point
Not available
๐Ÿ’จ Vapor Pressure
Not determined.
๐Ÿ“Š Solubility In Water
Soluble.
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Properties Status
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ“Š Form
Fluid
๐Ÿ’ง Solubility
Not available
๐Ÿงช Physical State
Fluid
Critical Property
๐Ÿ“Š Lower Explosive Limit
Not determined.
๐Ÿ“Š Molecular Weight
Not available
โš–๏ธ Density
Not determined.
Critical Property
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Upper Explosive Limit
Not determined.
๐Ÿงช Ph
7
๐Ÿ‘ƒ Odor
Odourless
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐ŸŽจ Colour
Not determined.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Colour Intensity
Not available
๐ŸงŠ Melting Point
Undetermined.
Critical Property
๐Ÿ”ฅ Flammability
Product is not flammable.
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No further data; see item 7.

๐Ÿงค Hand Protection

Wear protective gloves in order to be protected against chemical risks according to EN 420 and EN 374. As protection from splashes gloves made of Nitrile rubber, NBR are suitable. Recommended thickness of the material: 0.11 mm. No specific information can be given about breakthrough times as the product is a preparation consisting of different substances.

๐Ÿ‘๏ธ Eye Protection

Wear safety glasses in order to protect your eyes against chemical splashes according to EN 166.

๐Ÿ˜ท Respiratory Protection

Not necessary if room is well-ventilated.

๐Ÿฆบ Skin/Body Protection

Wear a laboratory coat for your protection against chemical splashes according to EN 340 and EN 369.

๐ŸŒ Environmental Exposure Controls

Comply with the current local and national environmental regulations.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Lumipulse G pTau 181 Plasma Calibrators, CAL 1, CAL 2, CAL 3, CAL 4, CAL 5?

The signal word for this substance is "warning".

What is the physical form of Lumipulse G pTau 181 Plasma Calibrators, CAL 1, CAL 2, CAL 3, CAL 4, CAL 5?

Lumipulse G pTau 181 Plasma Calibrators, CAL 1, CAL 2, CAL 3, CAL 4, CAL 5 is a fluid with not determined. color. It has odourless odor.

What is Lumipulse G pTau 181 Plasma Calibrators, CAL 1, CAL 2, CAL 3, CAL 4, CAL 5 used for?

Laboratory use. For product use see insert.

What are the hazard statements for Lumipulse G pTau 181 Plasma Calibrators, CAL 1, CAL 2, CAL 3, CAL 4, CAL 5?

This substance has 2 hazard statements: H317: May cause an allergic skin reaction. H412: Harmful to aquatic life with long lasting effects.

What is the melting point of Lumipulse G pTau 181 Plasma Calibrators, CAL 1, CAL 2, CAL 3, CAL 4, CAL 5?

The melting point is Undetermined. and the boiling point is Undetermined..