NextSDS Logo
Safety Data Sheet EN

Prothermal®

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Prothermal®
Product Code
2601

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals

Manufacturers & Suppliers

L

Lucerna-Chem AG

distributor

Abendweg 18, CH - 6006 Luzern

+41 (0)41 4209636

Emergency Contacts

Swiss Toxicological Informationcentre

145

Swiss Toxicological Informationcentre

+41 44-251 51 51

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Causes burns
Harmful if swallowed

GHS Pictograms

Precautionary Statements

Keep locked up and out of the reach of children.
If swallowed, seek medical advice immediately and show this container or label.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
sodium nitrite 7632-00-0 1 - 5% Yes
sodium hydroxide 1310-73-2 0.5 - 2% Yes
Benzyl-C12-16-alkyldimethyl-, Chloride EC: 270-325-2 68424-85-1 15% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Skin contact

Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. Consult a physician

Eye contact

Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician

Ingestion

Rinse mouth with water. Drink lots of water. Consult a physician.

Immediate Medical Attention

Consult a physician

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide

Specific hazards

No data available

Firefighter Protection

Wear self contained breathing apparatus for fire fighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Keep away from fire. Avoid breathing vapors, mist or gas. Ensure adequate ventilation.

Environmental

Prevent further leakage or spillage if safe to do so.

Cleanup methods

Mit flüssigkeitsbindenden Materialien aufnehmen. Nachreinigen.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with skin and eyes. Avoid inhalation of vapour or mist. For further precautions for safe handling referr to section 2.2.

Storage

Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Handle in accordance with good industrial hygiene and safety practice.

Hands

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it

Eyes

Tightly fitting safety goggles. Faceshield (8-inch minimum). Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Respiratory

Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Skin/Body

Complete suit protecting against chemicals, Flame retardant antistatic protective clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Dynamic Viscosity
no data available
Colour Intensity
---
Flash Point
no data available
Kinematic Viscosity
no data available
Softening Point
---
Metal Corrosion
---
Explosive Limits
---
Relative Evaporation Rate
---
Partition Coefficient
no data available
Physical State
liquid
Freezing Point
no data available
Solubility
---
Decomposition Temperature
no data available
Evaporation Rate
no data available
Form
---
Appearance
clear blue color
Density
---
Vapor Pressure
no data available
Cloud Point
---
Relative Density
no data available
Flammability
no data available
Properties Status
---
Odor
no data available
Ph
no data available
Odor Threshold
no data available
Voc Content
---
Bulk Density
---
Auto Ignition Temperature
no data available
Solubility In Fat
---
Physical State Data
liquid
Solidification Point
---
State Under Standard Conditions
---
Colour
clear blue color
Vapor Density
no data available
Solubility In Water
no data available
Lower Explosive Limit
no data available
Upper Explosive Limit
no data available
Boiling Point
100°C
Molecular Weight
---
Crystallisation Point
---
Melting Point
no data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

no data available

Reactivity

no data available

Hazardous reactions

no data available

Avoid

Heat, flames and sparks.

Incompatible

no data available

Decomposition

no data available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Offer surplus and non-recyclable solutions to a licensed disposal company.

Disposal

Offer surplus and non-recyclable solutions to a licensed disposal company.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
Not dangerous goods
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

no data available

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Prothermal®?

The signal word is na: r-phrases.

What is the physical form of Prothermal®?

Prothermal® is a liquid appearing as clear blue color with clear blue color color. It has no data available odor.

What is Prothermal® used for?

Laboratory chemicals

What is the melting point of Prothermal®?

The melting point is no data available and the boiling point is 100°C.