NextSDS Logo
Safety Data Sheet EN

Prothermal

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Prothermal
Product Code
2601

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals

Manufacturers & Suppliers

L

Lucerna-Chem AG

national supplier

Abendweg 18 CH - 6006 Luzern

+41 (0)41 4209636

Emergency Contacts

Swiss Toxicological Informationcentre

145

Swiss Toxicological Informationcentre

+41 44-251 51 51

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Causes burns.
Harmful if swallowed

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Natrium nitriet EC: 231-555-9 7632-00-0 1 - 5% Yes
Sodium Hydroxide (NaOH) EC: 215-185-5 1310-73-2 0.5 - 2% Yes
C 12 -C 16 -alkyldimethylammoniumchloride EC: 270-325-2 68424-85-1 15% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Skin contact

Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. Consult a physician

Eye contact

Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician

Ingestion

Rinse mouth with water. Drink lots of water. Consult a physician.

Immediate Medical Attention

no data available

Related Substances

Similar chemicals with comparable safety profiles

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Handle in accordance with good industrial hygiene and safety practice.

Hands

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it

Eyes

Tightly fitting safety goggles. Faceshield (8-inch minimum). Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Respiratory

Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Skin/Body

Complete suit protecting against chemicals, Flame retardant antistatic protective clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
clear blue color
Colour Intensity
---
Form
---
Odor
no data available
Odor Threshold
no data available
Ph
no data available
Melting Point
no data available
Boiling Point
100C
Flash Point
no data available
Freezing Point
no data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
no data available
Vapor Pressure
no data available
Vapor Density
no data available
Relative Density
no data available
Bulk Density
---
Density
---
Flammability
no data available
Upper Explosive Limit
no data available
Lower Explosive Limit
no data available
Explosive Limits
---
Auto Ignition Temperature
no data available
Decomposition Temperature
no data available
Solubility
---
Partition Coefficient
no data available
Solubility In Water
no data available
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Prothermal?

The signal word is na: r-phrases.

What is the physical form of Prothermal?

Prothermal is a liquid with clear blue color color. It has no data available odor.

What is Prothermal used for?

Laboratory chemicals

What is the melting point of Prothermal?

The melting point is no data available and the boiling point is 100C.