NextSDS Logo
Safety Data Sheet EN

THERMINOL® SP

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
THERMINOL® SP
Product Form
Substance
Product Code
00000000210

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Heat transferring agents

Manufacturers & Suppliers

S

Solutia Europe SPRL/BVBA

manufacturer

Parc Scientifique-Fleming; rue Laid Burniat, 3, B-1348 Louvain-la-Neuve (Sud) - BELGIUM

+32(0)10 48 15 50

S

Solutia UK Limited

manufacturer

Corporation Road, Newport, South Wales NP19 4XF, United Kingdom

+44 1633 27 8221

Emergency Contacts

Belgium

+32(0)3.568 5123

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

R53

GHS Pictograms

Hazard Statements

May cause long-term adverse effects in the aquatic environment.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
C14-30-alkylaromatic derivatives EC: 272-472-8 68855-24-3 100% Yes

Notes

See Section 16 for full text of R-phrases

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove patient to fresh air. If breathing is difficult give oxygen.

Skin contact

Wash immediately with plenty of water. Use soap if available.

Eye contact

Rinse immediately with plenty of water.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray, foam, dry chemical, or carbon dioxide

Specific hazards

None known

Firefighter Protection

Firefighters, and others exposed, wear self-contained breathing apparatus. Equipment should be thoroughly decontaminated after use.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Small spill

Absorb remaining material or small spills with an inert material and then place in a chemical waste container.

Large spill

Contain large spills with dikes and transfer the material to appropriate containers for reclamation or disposal.

Environmental

Keep out of drains and water courses.

Cleanup methods

Absorb remaining material or small spills with an inert material and then place in a chemical waste container. Flush spill area with water.

Materials: inert material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Good industrial practice in housekeeping and personal hygiene should be followed.

Storage

Keep in a cool, dry, well ventilated place.

Hygiene

Good industrial practice in housekeeping and personal hygiene should be followed.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Eyes

Wear chemical goggles. Have eye flushing equipment available.

Respiratory

Avoid breathing vapour or mist. Use approved respiratory protection equipment when airborne exposure is excessive. If used, full facepiece replaces the need for face shield and/or chemical goggles. Consult the respirator manufacturer to determine the appropriate type of equipment for a given application. Observe respirator use limitations specified by the manufacturer.

Skin/Body

Wear suitable protective clothing. Wear full protective clothing if exposed to splashes.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Flammability
---
Melting Point
---
Form
liquid
Solubility In Water
1 mg/l @ 25 C
Cloud Point
---
Relative Density
0,870 - 0,915 @ 16 C
Crystallisation Point
---
Molecular Weight
---
Explosive Limits
---
Appearance
---
Odor
characteristic
Physical State
liquid
Vapor Density
---
Partition Coefficient
---
Properties Status
---
Colour Intensity
---
Softening Point
---
Evaporation Rate
---
Auto Ignition Temperature
357 C Cleveland Open Cup
Dynamic Viscosity
---
Flash Point
177 C Cleveland Open Cup, 166 C Closed cup
Relative Evaporation Rate
---
Freezing Point
---
Solubility
---
Bulk Density
---
State Under Standard Conditions
---
Lower Explosive Limit
---
Boiling Point
335 - 390 C @ 1.013 hPa
Vapor Pressure
11 hPa @ 38 C
Decomposition Temperature
---
Upper Explosive Limit
---
Voc Content
---
Colour
pale yellow - amber
Ph
---
Metal Corrosion
---
Physical State Data
liquid
Kinematic Viscosity
13,0 - 34,1 mm2/s @ 37,8 C, 12,0 - 30,9 mm2/s @ 40 C
Odor Threshold
---
Density
854 - 908 kg/m3 @ 15 C, 847 - 901 kg/m3 @ 25 C
Solubility In Fat
---
Solidification Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

Hazardous polymerization does not occur.

Avoid

All sources of ignition.

Incompatible

None known

Decomposition

carbon dioxide, carbon monoxide (CO), smoke, soot, hydrocarbons

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Burn only in proper incinerator.

Disposal

Burn only in proper incinerator.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

EU Dangerous Substances Directive 67/548/EC. R53 - May cause long-term adverse effects in the aquatic environment. S61 - Avoid release to the environment. Contains: C14-30-alkylaromatic derivatives

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for THERMINOL® SP?

The signal word is no signal word.

What is the physical form of THERMINOL® SP?

THERMINOL® SP is a liquid with pale yellow - amber color. It has characteristic odor.

What is THERMINOL® SP used for?

Heat transferring agents

What are the hazard statements for THERMINOL® SP?

This substance has 1 hazard statement:

  • May cause long-term adverse effects in the aquatic environment.