NextSDS Logo
Safety Data Sheet EN

CD4 APC (SK3) CE

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
CD4 APC (SK3) CE
Product Code
345771

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Sector of Use SU24 Scientific research and development, Product category PC21 Laboratory chemicals, Process category PROC1 Use in closed process, no likelihood of exposure, Environmental release category ERC7 Industrial use of substances in closed systems

Manufacturers & Suppliers

B

Becton Dickinson Biosciences Centralized European Office

manufacturer

Erembodegem-Dorp 86, 9320 Erembodegem-Aalst, Belgium

Emergency Contacts

Becton Dickinson Biosciences Centralized European Office

+32 2 400 98 95

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Xn; Harmful

GHS Pictograms

Precautionary Statements

Do not breathe gas/fumes/vapour/spray (appropriate wording to be specified by the manufacturer).
Wear suitable protective clothing.
This material and its container must be disposed of as hazardous waste.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
Sodium azide 26628-22-8 0.1% Yes
inert --- 50 - 100% No
Gelatin 9000-70-8 2.5% No

For the wording of the listed risk phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Call for a doctor immediately. Seek immediate medical advice.

Immediate Medical Attention

Call for a doctor immediately. Seek immediate medical advice.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Specific hazards

Nitrogen oxides (NOx)

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required.

Environmental

Damp down dust with water spray.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures required.

Storage

Store in cool, dry conditions in well sealed receptacles.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Safety glasses

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colourless
Colour Intensity
---
Form
Liquid
Odor
Characteristic
Odor Threshold
---
Ph
7,0
Melting Point
Not determined
Boiling Point
100°C
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
Not applicable
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
Not determined
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
Product is not selfigniting.
Decomposition Temperature
---
Solubility
Soluble
Partition Coefficient
---
Solubility In Water
Soluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

No dangerous reactions known

Avoid

No further relevant information available.

Incompatible

No further relevant information available. Contact with acidic solutions and metal compounds over time may form potentially explosive metal azides.

Decomposition

Nitrogen oxides

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must be specially treated adhering to official regulations.

Disposal

Must not be disposed together with household garbage.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Void
Shipping Name
Void
Transport Class
Class Void
Packing Group
Void
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Labelling according to EU guidelines: The product has been classified and marked in accordance with EU Directives / Ordinance on Hazardous Materials

Chemical Safety Assessment Not performed

Code letter and hazard designation of product: Xn Harmful. Hazard-determining components of labeling: Sodium azide. Risk phrases: 22 Harmful if swallowed. Safety phrases: 23 Do not breathe gas/fumes/vapour/spray, 36 Wear suitable protective clothing, 60 This material and its container must be disposed of as hazardous waste.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for CD4 APC (SK3) CE?

The signal word is na: r-phrases.

What is the physical form of CD4 APC (SK3) CE?

CD4 APC (SK3) CE is a liquid with colourless color. It has characteristic odor.

What is the solubility of CD4 APC (SK3) CE?

Soluble

What is CD4 APC (SK3) CE used for?

Sector of Use SU24 Scientific research and development, Product category PC21 Laboratory chemicals, Process category PROC1 Use in closed process, no likelihood of exposure, Environmental release category ERC7 Industrial use of substances in closed systems

What is the melting point of CD4 APC (SK3) CE?

The melting point is Not determined and the boiling point is 100°C.