Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- GRF UNI-100 BO 250ML*24 ENDE
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Adhesive
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
Bison International
manufacturer
Dr.A.F.Philipsstraat 9, NL-4462 EW Goes, PO Box 160, NL-4460 AD Goes
+31 88 3235700
Emergency Contacts
National Poisons Information Centre
+353 (1) 809 2166
8.00 a.m. to 10.00 p.m. 7 days a week
Healthcare Professionals
+353 (1) 809 2566
24 hour service
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS07
GHS08
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Adhesive
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Tetrahydrofuran EC: 203-726-8 | 109-99-9 | 50 - 100% | Yes |
| Cyclohexanone EC: 203-631-1 | 108-94-1 | 10 - 25% | Yes |
| Butanone EC: 201-159-0 | 78-93-3 | 2.5 - 10% | Yes |
| Butylated hydroxytoluene EC: 204-881-4 | 128-37-0 | 0.025 - 0.25% | Yes |
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Call a doctor immediately. In case of unconsciousness place patient stably in side position for transportation.
Immediately wash with water and soap and rinse thoroughly.
Rinse opened eye for several minutes under running water. Then consult a doctor.
Rinse out mouth and then drink plenty of water.
Immediate Medical Attention
Call a doctor immediately.
Medical Treatment
No further relevant information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water haze, Alcohol resistant foam, Fire-extinguishing powder, Carbon dioxide
Water with full jet
No further relevant information available.
Cool endangered receptacles with water spray.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Do not allow to enter sewers/ surface or ground water.
Send for recovery or disposal in suitable receptacles. Absorb with liquid-binding material.
Related Products
Similar products with comparable safety profiles
GRF UNI-100 XT BO 1L*8 ENDE
---
GRF LOCK SPRAY AE 150ML*12 L223
---
GRF BLUE GEL JR 800G*12 L49
---
GRF GASLEAKDETECTOR AE 400ML*12 L313
---
GRF CLEANER PVC TI 1L*6 L058
CAS: 78-93-3
GRF CLEANER PVC TI 1L*6 L58
CAS: 78-93-3
GRF CLEANER PVC TI 1L*6 L58
CAS: 78-93-3
GRF VASELINE JR 1KG*6 L2
CAS: 8009-03-8
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good interior ventilation, especially at floor level. (Fumes are heavier than air). Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols.
Store in a cool location. Keep container tightly sealed. Store in cool, dry conditions in well sealed receptacles.
Keep ignition sources away - Do not smoke. Protect against electrostatic charges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see section 7.
Solvent resistant gloves
Tightly sealed goggles Goggles recommended during refilling
Suitable respiratory protective device recommended. In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Use suitable respiratory protective device in case of insufficient ventilation. Recommended filter device for short term use: Filter A
Use protective suit. Solvent resistant protective clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
Corrosive action on metals.
No further relevant information available.
No further relevant information available.
Danger of forming toxic pyrolysis products.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must not be disposed together with household garbage. Do not allow product to reach sewage system. Disposal must be made according to official regulations.
Must not be disposed together with household garbage. Do not allow product to reach sewage system. Disposal must be made according to official regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1133
- Shipping Name
- ADHESIVES
- Transport Class
- 3
- Packing Group
- III
Warning: Flammable liquids.
Warning: Flammable liquids.
Warning: Flammable liquids.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for GRF UNI-100 BO 250ML*24 ENDE?
The signal word is danger.
What is the physical form of GRF UNI-100 BO 250ML*24 ENDE?
GRF UNI-100 BO 250ML*24 ENDE is a fluid appearing as fluid with according to product specification color. It has characteristic odor.
What is the solubility of GRF UNI-100 BO 250ML*24 ENDE?
Not miscible or difficult to mix.
What is GRF UNI-100 BO 250ML*24 ENDE used for?
Adhesive
What are the hazard statements for GRF UNI-100 BO 250ML*24 ENDE?
This substance has 5 hazard statements:
- H225: Highly flammable liquid and vapour.
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
- H335: May cause respiratory irritation.
- H351: Suspected of causing cancer.
What is the melting point of GRF UNI-100 BO 250ML*24 ENDE?