NextSDS Logo
Safety Data Sheet EN

GRF UNI-100 BO 250ML*24 ENDE

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
GRF UNI-100 BO 250ML*24 ENDE

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Adhesive

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

B

Bison International

manufacturer

Dr.A.F.Philipsstraat 9, NL-4462 EW Goes, PO Box 160, NL-4460 AD Goes

+31 88 3235700

Emergency Contacts

National Poisons Information Centre

+353 (1) 809 2166

8.00 a.m. to 10.00 p.m. 7 days a week

Healthcare Professionals

+353 (1) 809 2566

24 hour service

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Carc. Cat. 2 H351
Eye Dam. Cat. 1 H318
Skin Irrit. Cat. 2 H315
STOT SE Cat. 3 H335

GHS Pictograms

GHS02 - Flammable

GHS02

GHS05 - Corrosive

GHS05

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H225 Highly flammable liquid and vapour.
H315 Causes skin irritation.
H318 Causes serious eye damage.
H335 May cause respiratory irritation.
H351 Suspected of causing cancer.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P261 Avoid breathing vapours.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P501 Dispose of contents/container in accordance with national regulations.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Adhesive

Chemical Name CAS Number Concentration Hazardous
Tetrahydrofuran EC: 203-726-8 109-99-9 50 - 100% Yes
Cyclohexanone EC: 203-631-1 108-94-1 10 - 25% Yes
Butanone EC: 201-159-0 78-93-3 2.5 - 10% Yes
Butylated hydroxytoluene EC: 204-881-4 128-37-0 0.025 - 0.25% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Call a doctor immediately. In case of unconsciousness place patient stably in side position for transportation.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Rinse out mouth and then drink plenty of water.

Immediate Medical Attention

Call a doctor immediately.

Medical Treatment

No further relevant information available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water haze, Alcohol resistant foam, Fire-extinguishing powder, Carbon dioxide

Unsuitable media

Water with full jet

Specific hazards

No further relevant information available.

Instructions

Cool endangered receptacles with water spray.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment. Keep unprotected persons away.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Send for recovery or disposal in suitable receptacles. Absorb with liquid-binding material.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good interior ventilation, especially at floor level. (Fumes are heavier than air). Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols.

Storage

Store in a cool location. Keep container tightly sealed. Store in cool, dry conditions in well sealed receptacles.

Fire prevention

Keep ignition sources away - Do not smoke. Protect against electrostatic charges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see section 7.

Hands

Solvent resistant gloves

Eyes

Tightly sealed goggles Goggles recommended during refilling

Respiratory

Suitable respiratory protective device recommended. In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device. Use suitable respiratory protective device in case of insufficient ventilation. Recommended filter device for short term use: Filter A

Skin/Body

Use protective suit. Solvent resistant protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Melting Point
Undetermined.
Evaporation Rate
Not determined.
Explosive Limits
---
Properties Status
---
Voc Content
78.77 %
Flash Point
-21 °C
Cloud Point
---
Physical State
Fluid
Physical State Data
liquid
Density
1.023 g/cm³
Kinematic Viscosity
Not determined.
Crystallisation Point
---
Freezing Point
Undetermined.
State Under Standard Conditions
---
Relative Evaporation Rate
---
Decomposition Temperature
Not determined.
Dynamic Viscosity
1450 mPas
Softening Point
---
Bulk Density
---
Solubility In Water
Not miscible or difficult to mix.
Upper Explosive Limit
12 Vol %
Form
Fluid
Solubility
Not miscible or difficult to mix.
Vapor Pressure
200 hPa (at 20 °C), 550 hPa (at 50 °C)
Lower Explosive Limit
1.3 Vol %
Odor
Characteristic
Solubility In Fat
---
Appearance
Fluid
Flammability
Highly flammable.
Auto Ignition Temperature
230 °C
Solidification Point
---
Boiling Point
65.5 °C
Ph
Not determined.
Partition Coefficient
Not determined.
Colour
According to product specification
Metal Corrosion
Void
Vapor Density
Not determined.
Colour Intensity
---
Odor Threshold
Not determined.
Relative Density
Not determined.
Molecular Weight
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

Corrosive action on metals.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

Danger of forming toxic pyrolysis products.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed together with household garbage. Do not allow product to reach sewage system. Disposal must be made according to official regulations.

Disposal

Must not be disposed together with household garbage. Do not allow product to reach sewage system. Disposal must be made according to official regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1133
Shipping Name
ADHESIVES
Transport Class
3
Packing Group
III
ADR

Warning: Flammable liquids.

IMDG

Warning: Flammable liquids.

IATA

Warning: Flammable liquids.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for GRF UNI-100 BO 250ML*24 ENDE?

The signal word is danger.

What is the physical form of GRF UNI-100 BO 250ML*24 ENDE?

GRF UNI-100 BO 250ML*24 ENDE is a fluid appearing as fluid with according to product specification color. It has characteristic odor.

What is the solubility of GRF UNI-100 BO 250ML*24 ENDE?

Not miscible or difficult to mix.

What is GRF UNI-100 BO 250ML*24 ENDE used for?

Adhesive

What are the hazard statements for GRF UNI-100 BO 250ML*24 ENDE?

This substance has 5 hazard statements:

  • H225: Highly flammable liquid and vapour.
  • H315: Causes skin irritation.
  • H318: Causes serious eye damage.
  • H335: May cause respiratory irritation.
  • H351: Suspected of causing cancer.

What is the melting point of GRF UNI-100 BO 250ML*24 ENDE?

The melting point is Undetermined. and the boiling point is 65.5 °C.

Compliance Scanner