Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- GRF LOCK SPRAY AE 150ML*12 L223
- Product Form
- AE
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Lubricant
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
Bison International
manufacturer
Dr.A.F.Philipsstraat 9, NL-4462 EW Goes, PO Box 160, NL-4460 AD Goes
+31 88 3235700
Emergency Contacts
National Poisons Information Centre, Beaumont Hospital, Dublin 9
01 8092566
8am-10pm (seven days)
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Lubricant
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, <2% aromatics EC: 918-481-9 | --- | 25 - 50% | Yes |
| Naphtha (petroleum), hydrotreated heavy EC: 919-857-5 | 64742-48-9 | 10 - 25% | Yes |
| n-Butan EC: 203-448-7 | 106-97-8 | 10 - 25% | Yes |
| Lubricating oils (petroleum), C15-30, hydrotreated neutral oil-based (Nota L, -R45, <3% dimethyl sulfoxide) EC: 276-737-9 | 72623-86-0 | 2.5 - 10% | Yes |
| propane EC: 200-827-9 | 74-98-6 | 2.5 - 10% | Yes |
| 4,5-dihydro-2-heptadecyl-1H-imidazole-1-ethylamine EC: 221-133-2 | 3010-23-9 | 0.25 - 1% | Yes |
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Rinse opened eye for several minutes under running water.
If symptoms persist consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
No further relevant information available.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Inform respective authorities in case of seepage into water course or sewage system. Do not allow to enter sewers/ surface or ground water.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation/exhaustion at the workplace.
Observe official regulations on storing packagings with pressurised containers. Keep container tightly sealed.
Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see item 7.
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Recommended thickness of the material: > 0,12 mm, Nitrile rubber, NBR. Penetration time of glove material: For the mixture of chemicals mentioned below the penetration time has to be at least 10 minutes (Permeation according to EN 374 Part 3: Level 1).
Not required.
Not required.
Use protective suit.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No further relevant information available.
No further relevant information available.
Danger of forming toxic pyrolysis products.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must not be disposed together with household garbage. Do not allow product to reach sewage system. Disposal must be made according to official regulations.
Must not be disposed together with household garbage. Do not allow product to reach sewage system. Disposal must be made according to official regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2
- Packing Group
- not regulated
Warning: Gases.
Warning: Gases.
Warning: Gases.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for GRF LOCK SPRAY AE 150ML*12 L223?
The signal word is danger.
What is the physical form of GRF LOCK SPRAY AE 150ML*12 L223?
GRF LOCK SPRAY AE 150ML*12 L223 is a aerosol with according to product specification color. It has characteristic odor.
What is the solubility of GRF LOCK SPRAY AE 150ML*12 L223?
Not miscible or difficult to mix.
What is GRF LOCK SPRAY AE 150ML*12 L223 used for?
Lubricant
What are the hazard statements for GRF LOCK SPRAY AE 150ML*12 L223?
This substance has 3 hazard statements:
- H222: Extremely flammable aerosol. Pressurised container: May burst if heated.
- H336: May cause drowsiness or dizziness.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of GRF LOCK SPRAY AE 150ML*12 L223?
The melting point is Undetermined. and the boiling point is 175 °C.