Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
GRF LOCK SPRAY AE 150ML*12 L223
Product Form
AE

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Lubricant

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

B

Bison International

manufacturer

Dr.A.F.Philipsstraat 9, NL-4462 EW Goes, PO Box 160, NL-4460 AD Goes

+31 88 3235700

Emergency Contacts

National Poisons Information Centre, Beaumont Hospital, Dublin 9

01 8092566

8am-10pm (seven days)

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
STOT SE Cat. 3 H336
Asp. Tox. Cat. 1 H304
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H222 Extremely flammable aerosol. Pressurised container: May burst if heated.
H336 May cause drowsiness or dizziness.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P261 Avoid breathing spray.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F.
P501 Dispose of contents/container in accordance with national regulations.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Lubricant

Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, <2% aromatics EC: 918-481-9 --- 25 - 50% Yes
Naphtha (petroleum), hydrotreated heavy EC: 919-857-5 64742-48-9 10 - 25% Yes
n-Butan EC: 203-448-7 106-97-8 10 - 25% Yes
Lubricating oils (petroleum), C15-30, hydrotreated neutral oil-based (Nota L, -R45, <3% dimethyl sulfoxide) EC: 276-737-9 72623-86-0 2.5 - 10% Yes
propane EC: 200-827-9 74-98-6 2.5 - 10% Yes
4,5-dihydro-2-heptadecyl-1H-imidazole-1-ethylamine EC: 221-133-2 3010-23-9 0.25 - 1% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment. Keep unprotected persons away.

Environmental

Inform respective authorities in case of seepage into water course or sewage system. Do not allow to enter sewers/ surface or ground water.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace.

Storage

Observe official regulations on storing packagings with pressurised containers. Keep container tightly sealed.

Fire prevention

Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Recommended thickness of the material: > 0,12 mm, Nitrile rubber, NBR. Penetration time of glove material: For the mixture of chemicals mentioned below the penetration time has to be at least 10 minutes (Permeation according to EN 374 Part 3: Level 1).

Eyes

Not required.

Respiratory

Not required.

Skin/Body

Use protective suit.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Lower Explosive Limit
0.5 Vol %
Bulk Density
---
Vapor Pressure
2 hPa
Dynamic Viscosity
Not determined.
Partition Coefficient
Not determined.
State Under Standard Conditions
---
Odor
Characteristic
Kinematic Viscosity
Not determined.
Evaporation Rate
Not applicable.
Properties Status
---
Relative Density
Not determined.
Physical State
Aerosol
Boiling Point
175 °C
Colour Intensity
---
Colour
According to product specification
Explosive Limits
---
Auto Ignition Temperature
Product is not selfigniting.
Solubility In Fat
---
Freezing Point
Undetermined.
Cloud Point
---
Decomposition Temperature
Not determined.
Melting Point
Undetermined.
Molecular Weight
---
Density
0.74 g/cm³
Appearance
---
Flash Point
-97 °C
Odor Threshold
Not determined.
Ph
Not determined.
Physical State Data
aerosol
Relative Evaporation Rate
---
Solubility
Not miscible or difficult to mix.
Vapor Density
Not determined.
Form
Aerosol
Softening Point
---
Flammability
Not applicable.
Upper Explosive Limit
7 Vol %
Solidification Point
---
Voc Content
---
Metal Corrosion
Void
Solubility In Water
Not miscible or difficult to mix.
Crystallisation Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

Danger of forming toxic pyrolysis products.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed together with household garbage. Do not allow product to reach sewage system. Disposal must be made according to official regulations.

Disposal

Must not be disposed together with household garbage. Do not allow product to reach sewage system. Disposal must be made according to official regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1950
Shipping Name
AEROSOLS
Transport Class
2
Packing Group
not regulated
ADR

Warning: Gases.

IMDG

Warning: Gases.

IATA

Warning: Gases.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for GRF LOCK SPRAY AE 150ML*12 L223?

The signal word is danger.

What is the physical form of GRF LOCK SPRAY AE 150ML*12 L223?

GRF LOCK SPRAY AE 150ML*12 L223 is a aerosol with according to product specification color. It has characteristic odor.

What is the solubility of GRF LOCK SPRAY AE 150ML*12 L223?

Not miscible or difficult to mix.

What is GRF LOCK SPRAY AE 150ML*12 L223 used for?

Lubricant

What are the hazard statements for GRF LOCK SPRAY AE 150ML*12 L223?

This substance has 3 hazard statements:

  • H222: Extremely flammable aerosol. Pressurised container: May burst if heated.
  • H336: May cause drowsiness or dizziness.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of GRF LOCK SPRAY AE 150ML*12 L223?