Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Benzonase® Nuclease, ultrapure
- Product Code
- E8263
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals, Synthesis of substances
Uses advised against
The product is being supplied under the TSCA R&D Exemption (40 CFR Section 720.36). It is the recipient's responsibility to comply with the requirements of the R&D exemption. The product may not be used for a non-exempt commercial purpose under TSCA unless appropriate consent is granted in writing by MilliporeSigma.
Manufacturers & Suppliers
Sigma-Aldrich Inc.
manufacturer
3050 SPRUCE ST, ST. LOUIS MO 63103, UNITED STATES
+1 314 771-5765
Emergency Contacts
CHEMTREC (USA)
800-424-9300
24 Hours/day; 7 Days/week
CHEMTREC (International)
+1-703-527-3887
24 Hours/day; 7 Days/week
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Synonyms: Endonuclease
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| glycerine EC: 200-289-5 | 56-81-5 | 50 - 70% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
After inhalation: fresh air.
In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.
After eye contact: rinse out with plenty of water. Remove contact lenses.
After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.
Immediate Medical Attention
Consult doctor if feeling unwell.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, Carbon dioxide (CO2), Dry powder
For this substance/mixture no limitations of extinguishing agents are given.
Carbon oxides, Mixture with combustible ingredients. Development of hazardous combustion gases or vapours possible in the event of fire.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not breathe vapors, aerosols. Evacuate the danger area, observe emergency procedures, consult an expert.
Do not let product enter drains.
Take up with liquid-absorbent material (e.g. Chemizorb®).
Materials: liquid-absorbent material (e.g. Chemizorb®)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For precautions see section 2.2.
Tightly closed.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. Material: Nitrile rubber, Minimum layer thickness: 0.11 mm, Break through time: 480 min, Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M), data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
Not required; except in case of aerosol formation.
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is chemically stable under standard ambient conditions (room temperature).
No data available
No data available
no information available
Strong oxidizing agents Strong oxidizing agents
In the event of fire: see section 5
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Leave chemicals in original containers. No mixing with other waste.
Waste material must be disposed of in accordance with the national and local regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Benzonase® Nuclease, ultrapure?
The signal word is no signal word.
What is the physical form of Benzonase® Nuclease, ultrapure?
Benzonase® Nuclease, ultrapure is a liquid appearing as form: liquid . It has no data available odor.
What is Benzonase® Nuclease, ultrapure used for?
Laboratory chemicals, Synthesis of substances
What is the melting point of Benzonase® Nuclease, ultrapure?
The melting point is No data available and the boiling point is No data available.