01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Benzonase® Nuclease
Product Code
E1014

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals, Synthesis of substances

Manufacturers & Suppliers

S

Sigma-Aldrich Inc.

manufacturer

3050 SPRUCE ST ST. LOUIS MO 63103 UNITED STATES

+1 314 771-5765

Emergency Contacts

CHEMTREC

800-424-9300

24 Hours/day; 7 Days/week

CHEMTREC

+1-703-527-3887

24 Hours/day; 7 Days/week

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
glycerine EC: 200-289-5 56-81-5 50 - 70% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

fresh air.

Skin contact

Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

rinse out with plenty of water. Remove contact lenses.

Ingestion

make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam Carbon dioxide (CO2) Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Carbon oxides. Mixture with combustible ingredients. Development of hazardous combustion gases or vapours possible in the event of fire.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not breathe vapors, aerosols. Evacuate the danger area, observe emergency procedures, consult an expert.

Environmental

Do not let product enter drains.

Cleanup methods

Take up with liquid-absorbent material (e.g. Chemizorb®). Clean up affected area.

Materials: liquid-absorbent material (e.g. Chemizorb®)

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. Full contact: Material: Nitrile rubber, Minimum layer thickness: 0.11 mm, Break through time: 480 min, Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M). Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0.11 mm, Break through time: 480 min, Material tested: Dermatril® (KCL 740 / Aldrich Z677272, Size M). data source: KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail sales@kcl.de, test method: EN374. If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the EC approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

Not required; except in case of aerosol formation.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
liquid
Colour
---
Colour Intensity
---
Form
liquid
Odor
No data available
Odor Threshold
No data available
Ph
No data available
Melting Point
No data available
Boiling Point
No data available
Flash Point
No data available
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
No data available
Relative Density
No data available
Bulk Density
---
Density
---
Flammability
No data available
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
No data available
Solubility In Water
No data available
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

No data available

Hazardous reactions

No data available

Avoid

no information available

Incompatible

Strong oxidizing agents

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Mixture No data available

12.2 Persistence and degradability

No data available

12.3 Bioaccumulative potential

No data available

12.4 Mobility in soil

No data available

12.5 Results of PBT and vPvB assessment

PBT/vPvB assessment not available as chemical safety assessment not required/not conducted

PBT/vPvB assessment not available as chemical safety assessment not required/not conducted

12.1 Toxicity

Toxicity to fish static test LC50 - Oncorhynchus mykiss (rainbow trout) - 54,000 mg/l - 96 h Remarks: (ECHA) Toxicity to daphnia and other aquatic invertebrates Remarks: No data available Toxicity to algae Remarks: No data available

12.6 Other adverse effects

No data available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Waste material must be disposed of in accordance with the national and local regulations.

Disposal

Leave chemicals in original containers. No mixing with other waste.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Benzonase® Nuclease?

The signal word is no signal word.

What is the physical form of Benzonase® Nuclease?

Benzonase® Nuclease is a liquid appearing as liquid . It has no data available odor.

What is Benzonase® Nuclease used for?

Laboratory chemicals, Synthesis of substances

What is the melting point of Benzonase® Nuclease?

The melting point is No data available and the boiling point is No data available.