Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LINOMAX plus Spezialfettpaste
- Product Form
- Mixture
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Lubricants, Greases and Release Products
Uses advised against
No additional information available
Manufacturers & Suppliers
H.-D. SCHUNK GmbH & Co. Spanntechnik KG
manufacturer
Lothringer Str. 23, 88512 Mengen - Deutschland
+49-7572-7614-1300
Emergency Contacts
VIZ Freiburg
+49-761-19240
24 h
DE, EN
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Distillates (petroleum), hydrotreated heavy paraffinic; Baseoil— unspecified; [A complex combination of hydrocarbons obtained by treating a petroleum fraction with hydrogen in the presence of a catalyst. It consists of hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and produces a finished oil of at least 100 SUS at 100°F (19cSt at 40°C). It contains a relatively large proportion of saturated hydrocarbons.] EC: 265-157-1 | 64742-54-7 | 13 - 23% | Yes |
| Distillates (petroleum), hydrotreated heavy naphthenic; Baseoil— unspecified; [A complex combination of hydrocarbons obtained by treating a petroleum fraction with hydrogen in the presence of a catalyst. It consists of hydrocarbons having carbon numbers predominantly in the range of C20 through C50 and produces a finished oil of at least 100 SUS at 100°F (19cSt at 40 °C). It contains relatively few normal paraffins.] EC: 265-155-0 | 64742-52-5 | 15% | Yes |
| Polybutene EC: 500-004-7 | 9003-29-6 | 7 - 11% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air and keep comfortable for breathing. If you feel unwell, seek medical advice.
Immediately remove contaminated clothing or footwear. Rinse and then wash skin thoroughly with water and soap. If skin irritation or rash occurs: Get medical advice/attention.
Wash with plenty of water (during 20 minutes minimum) with eyes wide open after taking off soft contact lenses and immediately take medical advice.
Rinse mouth with water, do not induce vomiting, call a doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
water, carbon dioxide (CO2), powder and foam. If there is a fire close by, use suitable extinguishing agents.
Do not use a heavy water stream.
Do not allow run-off from fire fighting to enter drains or water courses. Do not contaminate ground and surface water.
Firefighter Protection
Extra personal protection: complete protective clothing including self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate the danger area. Keep public away from danger area. Mark the danger area.
Prevent entry to sewers and public waters.
Mechanically recover the product. Place in a suitable container for disposal in accordance with the waste regulations (see Section 13).
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid dust formation. If dust are formed : Dust may form flammable and explosive mixture with air.
Store in original container. Keep container closed when not in use. Store in a dry, cool and well-ventilated place.
Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Wash hands and other exposed areas with soap and water before leaving work. Apply emollient cream.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure good ventilation of the work station.
If exposed: Chemically resistant protective gloves (EN 374). Choosing the proper glove is a decision that depends not only on the type of material, but also on other quality features, which differ for each manufacturer. Material: Nitrile rubber. Fluoroelastomer (FKM). material thickness: 0,4 mm
Safety glasses
No respiratory protection needed under normal use conditions. Vapours or aerosols : Wear respiratory protection. Filter type: P
Wear proper protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No dangerous reactions known under normal conditions of use.
No additional information available
No additional information available
Oxidizing agent.
butene, mixed-1-and-2-isomers.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Do not dispose of with domestic waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not applicable
- Shipping Name
- Not applicable
- Transport Class
- Not applicable
- Packing Group
- Not applicable
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LINOMAX plus Spezialfettpaste?
The signal word is no signal word.
What is the physical form of LINOMAX plus Spezialfettpaste?
LINOMAX plus Spezialfettpaste is a solid appearing as paste with beige color. It has characteristic odor.
What is the solubility of LINOMAX plus Spezialfettpaste?
No data available
What is LINOMAX plus Spezialfettpaste used for?
Lubricants, Greases and Release Products
What is the melting point of LINOMAX plus Spezialfettpaste?
The melting point is No data available and the boiling point is No data available.