NextSDS Logo
Safety Data Sheet EN

UV 420 TTR-C H4

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
UV 420 TTR-C H4

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Flux for Submerged Arc Welding

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

voestalpine Böhler Welding Germany GmbH logo

voestalpine Böhler Welding Germany GmbH

manufacturer

Hafenstr. 21, 59067 Hamm, Germany

+49 2381 271 - 578

http://www.voestalpine.com/welding

Emergency Contacts

NCEC

+44 1235 239670

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
manganese EC: 231-105-1 7439-96-5 0.1 - 2.5% No
potassium silicate EC: 215-199-1 1312-76-1 2.5 - 5% Yes
Silicic acid, sodium salt EC: 215-687-4 1344-09-8 2.5 - 5% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

Seek medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Suitable to surrounding conditions. For deletion of fire just use dry powders.

Unsuitable media

water or halogenated containing extinguishing agents

Instructions

For deletion of fire just use dry powders.

Firefighter Protection

Wear fully protective suit.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Pick up mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure that suitable extractors are available on processing machines

Storage

Store only in the original receptacle.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

EN 12477. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Leather gloves. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Safety glasses

Respiratory

Filter P2

Skin/Body

Protective work clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Molecular Weight
---
Freezing Point
---
Physical State
Granulate
Vapor Pressure
---
Metal Corrosion
---
Solubility
---
Solubility In Water
Insoluble.
Flash Point
Not applicable.
Partition Coefficient
Not determined.
Softening Point
---
Evaporation Rate
Not applicable.
Voc Content
---
Relative Density
Not determined.
Appearance
Granulate
Crystallisation Point
---
Form
Granulate
Properties Status
---
Colour Intensity
---
Solubility In Fat
---
Boiling Point
---
Lower Explosive Limit
Not determined.
Flammability
Not determined.
Kinematic Viscosity
Not applicable.
Cloud Point
---
Melting Point
---
Upper Explosive Limit
Not determined.
Dynamic Viscosity
Not applicable.
Solidification Point
---
Bulk Density
---
Odor
Odourless
Colour
Not determined.
Auto Ignition Temperature
Product is not selfigniting.
Relative Evaporation Rate
---
Vapor Density
Not applicable.
Odor Threshold
Not determined.
State Under Standard Conditions
---
Explosive Limits
---
Decomposition Temperature
Not determined.
Physical State Data
solid
Density
Not determined.
Ph
Not applicable.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used and stored according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

Attacks materials containing glass and silicate.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must be specially treated adhering to official regulations.

Disposal

Must be specially treated adhering to official regulations.

Waste Codes

12 01 13 welding wastes EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Void
Shipping Name
Void
Transport Class
Void
Packing Group
Void
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for UV 420 TTR-C H4?

The signal word is no signal word.

What is the physical form of UV 420 TTR-C H4?

UV 420 TTR-C H4 is a granulate appearing as granulate with not determined. color. It has odourless odor.

What is UV 420 TTR-C H4 used for?

Flux for Submerged Arc Welding