Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
European Community number - used for regulatory compliance in EU/EEA
Uses Information
Overview
UTB AQUILLA 150 (CAS: 64741-88-4 ) commonly used base oil for further processing, having regard to the application proposed and identified by concawe. the specification of the identified applications is not required because the substance is not subject to registration as per reach regulation..
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Manufacturers & Suppliers
Authorized suppliers, manufacturers, and distribution network information
UTB B.V.
manufacturer
Mandenmakerstraat 21-25 2984 AS Ridderkerk Netherlands
NL
+31 (0) 88 0202 300
24/7 Emergency Response
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
CHEMTREC
+1-703-527-3887
US
24h a day / 7 days a week
worldwide
Emergency Contact
+43 1 3649237
AT
Austria
Emergency Contact
+32 2 808 32 37
BE
Belgium
Emergency Contact
+359 32 570 104
BG
Bulgaria
Emergency Contact
+420 228 880 039
CZ
Czech Republic
Emergency Contact
+45 69 91 85 73
DK
Denmark
Emergency Contact
+49 69 643508409
DE
Germany
Emergency Contact
+972 3-763-0639
IL
Israel
Emergency Contact
+371 66 165 504
LV
Latvia
Emergency Contact
+370 5 214 0238
LT
Lithuania
Emergency Contact
+60 3-9212 5794
MY
Malaysia
Emergency Contact
+389 2 551 7456
MK
Macedonia
Emergency Contact
+31 85 888 0596
NL
The Netherlands
Emergency Contact
+48 22 398 80 29
PL
Poland
Emergency Contact
+40 376 300 026
RO
Romania
Emergency Contact
+8 (800) 100-63-46
RU
Russia
Emergency Contact
+46 8 525 034 03
SE
Sweden
Emergency Contact
+386 1 888 80 16
SI
Slovenia
Emergency Contact
+886 2 7741 4207
TW
Taiwan
Emergency Contact
080 822 1374
KR
South Korea
Emergency Contact
+380 94 710 1374
UA
Ukraine
Emergency Contact
+36 1 808 8425
HU
Hungary
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
substanceGeneral Composition
Mineral oil
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Mineral oil | N/A | Not specified | Non-hazardous |
Additional Information
The substance does not require registration according to Regulation (EC) No 1907/2006 [REACH]. [Item 2.7 d]
Composition Notes
The mineral oils in the product contain less than 3% DMSO extract (IP 346).
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
Inhalation Exposure
In the event of symptoms take medical treatment. Remove the casualty into fresh air and keep him calm.
Skin Contact
After contact with skin, wash immediately with plenty of water and soap. Consult a doctor if skin irritation persists. Remove contaminated clothing.
Eye Contact
Separate eyelids, wash the eyes thoroughly with water (15 min.). Take medical treatment.
Ingestion/Swallowing
Do not induce vomiting - aspiration hazard. Summon a doctor immediately.
Immediate Medical Attention Required
In case of persistent symptoms consult doctor. Summon a doctor immediately (for ingestion). Take medical treatment (for eye contact and inhalation).
Medical Treatment
Treat symptomatically
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment
Occupational exposure limits, engineering controls, and required safety equipment
Engineering Controls
Technical measures for preventing exposition. Organisational measures for preventing exposition. Provide adequate ventilation. The type of personal protective equipment must be selected depending on the concentration and quantity of the hazardous substance at the workplace.
Hand Protection
For this purpose, protective gloves are suitable, for instance, made by the company KCL GmbH, D-36124 Eichenzell, phone +49 (0)6659 87300, e-mail: vertrieb@kcl.de with the following specification (tested as per EN374): Use Permanent hand contact Camatril (Item No: 731; Material: Nitrile; Minimum layer thickness: 0.33 mm; Burst time: 480 min) Dermatril (Item No: 740; Material: Nitrile; Minimum layer thickness: 0.11 mm; Burst time: 30 min) The protective gloves to be used must comply with the specifications of the EU directive 89/686/EEC and the standard EN374 derived from it. The above mentioned burst times are based on laboratory measurements of KCL made as per EN 374 and a re applicable only for this KCL product. Preventive skin protection by protective skin ointment.
Eye Protection
Tightly fitting safety glasses; Eye protection must comply with EN 166.
Respiratory Protection
Not necessary, but do not inhale vapours. In situations where misting or flying may occur use appropriate certified respirators. Short term: filter apparatus, combination filter A-P2
Skin/Body Protection
Clothing as usual in the chemical industry. Protective gloves resistant to chemicals; With steel toe cap. Preventive skin protection by protective skin ointment.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for UTB AQUILLA 150?
The signal word for this substance is "no signal word".
What is the physical form of UTB AQUILLA 150?
UTB AQUILLA 150 is a liquid with light yellow color. It has characteristic odor.
What is the solubility of UTB AQUILLA 150?
virtually insoluble
What is UTB AQUILLA 150 used for?
Base oil for further processing, Having regard to the application proposed and identified by CONCAWE. The specification of the identified applications is not required because the substance is not subject to registration as per REACH regulation.
What is the melting point of UTB AQUILLA 150?
The melting point is not determined and the boiling point is > 300 C.