Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- AQUA-SOL NEUTRA SPLIT
- Product Code
- 11004058X1 (CLP)
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- KAW2-80N0-M00G-QD57
Identified Uses
Water based degreaser.
Manufacturers & Suppliers
NCH UK & Ireland
Arrowmere House, Bilston, WV14 0QL
042 939 5502
www.ncheurope.com
Emergency Contacts
Emergency Contact
01902 510200
available during Office Hours
Emergency Contact
01 809 2166
available from 8am to 10pm daily
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| C9-C11 ALCOHOL ETHOXYLATE (4EO) | 68439-46-3 | 10 - 20% | Yes |
| DISODIUM DICARBOXYETHYL COCOPROPYLENEDIAMINE EC: 307-455-7 | 97659-50-2 | 3 - 5% | Yes |
For any H statements mentioned in this section, see the full text in section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Wash off immediately with soap and plenty of water removing all contaminated clothes and shoes. Get medical attention if irritation develops and persists.
Symptoms: May cause irritation as itching or redness.
In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention if irritation develops and persists.
Symptoms: May cause irritation as itching and redness.
Rinse mouth with water. If swallowed, seek medical advice immediately and show this container or label. Do NOT induce vomiting.
Immediate Medical Attention
Get medical attention immediately if symptoms occur. If swallowed, seek medical advice immediately and show this container or label.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
General ventilation is normally adequate.
Long term use eg continuous wear or immersion ;. Wear suitable protective gloves conforming to EN 374. Type of gloves suggested :. Nitrile rubber (0.4 mm). PVC (0.7mm). Neoprene gloves (0.4 mm). Minimum breakthrough time of the glove material (protective index 4, breakthrough time: >120 min). For break through times, refer to glove manufacturers recommendations.
Safety glasses with side-shields. Approved to EN 166. For large volumes, faceshields should be used.
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Conforming to EN 143 - P2 / P3 Particle filters.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for AQUA-SOL NEUTRA SPLIT?
The signal word is warning.
What is the physical form of AQUA-SOL NEUTRA SPLIT?
AQUA-SOL NEUTRA SPLIT is a liquid appearing as blue with blue color. It has slight odor.
What is the solubility of AQUA-SOL NEUTRA SPLIT?
Soluble in water
What is AQUA-SOL NEUTRA SPLIT used for?
Water based degreaser.
What are the hazard statements for AQUA-SOL NEUTRA SPLIT?
This substance has 1 hazard statement:
- H319: Causes serious eye irritation
What is the melting point of AQUA-SOL NEUTRA SPLIT?
The melting point is -5 C and the boiling point is 100 C.