NextSDS Logo
Safety Data Sheet EN

ECO Interior 10

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ECO Interior 10

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Interior cleaner for professional use (AISE_SUMI_PW_8a_2; AISE_SUMI_PW_10_1; AISE_SUMI_PW_11_1; AISE_SUMI_PW_19_1)

Manufacturers & Suppliers

Greenspeed logo

Greenspeed

national supplier

P.O.Box 1250, 2280 CG Rijswijk (ZH), NL

+31703458737

http://www.greenspeed.eu/

Emergency Contacts

Emergency Contact

+32 70 245 245

Emergency Contact

+31 30 274 88 88

Emergency Contact

+33 (0)1 45 42 59 59

Emergency Contact

(+352) 8002-5500

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Sodium Laureth Sulfate EC: 500-234-8 68891-38-3 4% Yes
3-Butoxypropane-2-ol EC: 225-878-4 5131-66-8 2% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of serious or continuous discomforts: remove to fresh air and seek medical attention.

Skin contact

Rinse with water.

Eye contact

Rinse first with plenty of water, if necessary seek medical attention.

Symptoms: Redness

Ingestion

Rinse first with plenty of water, if necessary seek medical attention.

Symptoms: Diarrhoea, headache, abdominal cramps, sleepiness, vomiting

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, foam, powder, sprayed water

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not walk into or touch spilled substances and avoid inhalation of fumes, smoke, dusts and vapours by staying up wind. Remove any contaminated clothing and used contaminated protective equipment and dispose of it safely.

Environmental

Do not allow to flow into sewers or open water.

Cleanup methods

If possible, remove by using absorbent material.

Materials: absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handle with care to avoid spillage.

Storage

Keep in a sealed container in a closed, frost-free, ventilated room.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

If necessary, use with sufficient exhaust ventilation.

Hands

Handling with nitril-gloves (EN 374). Breakthrough time: >480' Material thickness: 0,35 mm. Thoroughly check gloves before use. Take of the gloves properly without touching the outside with your bare hands. The manufacturer of the protective gloves has to be consulted about the suitability for a specific work station. Wash and dry your hands.

Eyes

Keep an eye-rinse bottle within reach. Tight-fitting safety goggles. Wear a face shield and protective suit in case of exceptional processing problems.

Respiratory

Respiratory protection is not required. Use ABEK type gas masks in case of irritating exposure.

Skin/Body

Wear impermeable clothing. The type of protective equipment depends on the concentration and amount of hazardous substances at the work station in question.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Freezing Point
---
Physical State Data
liquid
Upper Explosive Limit
8.700 %
Flammability
Not applicable
Cloud Point
---
Solubility
---
Solidification Point
---
Odor Threshold
Not applicable
Relative Evaporation Rate
---
Relative Density
1.0130 kg/l
Partition Coefficient
Not applicable
State Under Standard Conditions
---
Colour Intensity
---
Melting Point
0 °C
Density
---
Ph
10.5
Lower Explosive Limit
1.100 %
Softening Point
---
Solubility In Fat
---
Crystallisation Point
---
Vapor Pressure
2 332 Pa
Auto Ignition Temperature
207 °C
Evaporation Rate
2.000
Colour
---
Vapor Density
Not applicable
Metal Corrosion
---
Properties Status
---
Odor
characteristic
Form
---
Bulk Density
---
Physical State
Liquid
Molecular Weight
---
Appearance
Liquid
Dynamic Viscosity
1 mPa.s
Flash Point
/
Kinematic Viscosity
1 mm²/s
Boiling Point
100 °C — 199 °C
Solubility In Water
Completely soluble
Decomposition Temperature
/
Explosive Limits
---
Voc Content
4.00 %
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Extremely high or low temperatures.

Reactivity

Stable under normal conditions.

Avoid

Protect from sunlight and do not expose to temperatures exceeding + 50°C.

Decomposition

Under recommended usage conditions, hazardous decomposition products are not expected.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The product may be discharged in the indicated percentages of utilization, provided it is neutralised to pH 7.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not applicable
Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for ECO Interior 10?

The signal word is no signal word.

What is the physical form of ECO Interior 10?

ECO Interior 10 is a liquid appearing as liquid . It has characteristic odor.

What is ECO Interior 10 used for?

Interior cleaner for professional use (AISE_SUMI_PW_8a_2; AISE_SUMI_PW_10_1; AISE_SUMI_PW_11_1; AISE_SUMI_PW_19_1)

What is the melting point of ECO Interior 10?

The melting point is 0 °C and the boiling point is 100 °C — 199 °C.