NextSDS Logo
EC

ECO Interior 10

NO SIGNAL WORD Liquid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
ECO Interior 10

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Interior cleaner for professional use (AISE_SUMI_PW_8a_2; AISE_SUMI_PW_10_1; AISE_SUMI_PW_11_1; AISE_SUMI_PW_19_1)

Overview

ECO Interior 10 is a liquid substance commonly used interior cleaner for professional use (aise_sumi_pw_8a_2; aise_sumi_pw_10_1; aise_sumi_pw_11_1; aise_sumi_pw_19_1).

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Greenspeed company logo - Safety Data Sheet supplier organization

Greenspeed

undefined

P.O.Box 1250 2280 CG Rijswijk (ZH), NL

NL

+31703458737

+31703458942

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+32 70 245 245

BE

Emergency Contact

+31 30 274 88 88

NL

Uitsluitend voor professionele hulpverleners

Emergency Contact

+ 33 (0)1 45 42 59 59

FR

Emergency Contact

(+352) 8002-5500

LU

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
N/A N/A 4% Non-hazardous
N/A N/A 2% Non-hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

In case of serious or continuous discomforts: remove to fresh air and seek medical attention.

Skin Contact

Rinse with water.

Eye Contact

Rinse first with plenty of water, if necessary seek medical attention.

Symptoms:

Redness

Ingestion/Swallowing

Rinse first with plenty of water, if necessary seek medical attention.

Symptoms:

Diarrhoea, headache, abdominal cramps, sleepiness, vomiting

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Metal Corrosion
Not available
Solubility In Water
Completely soluble
Auto Ignition Temperature
207 C
Lower Explosive Limit
1.100 %
Physical State
Liquid
Critical Property
Density
Not available
Explosive Limits
Not available
Kinematic Viscosity
1 mm/s
Flammability
Not applicable
Colour
Not available
Appearance
Liquid
Voc Content
4.00 %
Relative Density
1.0130 kg/l
Flash Point
/
Critical Property
Ph
10.5
Colour Intensity
Not available
Upper Explosive Limit
8.700 %
Bulk Density
Not available
Odor
characteristic
Form
Not available
Melting Point
0 C
Critical Property
Dynamic Viscosity
1 mPa.s
Decomposition Temperature
/
Boiling Point
100 C 199 C
Critical Property
Molecular Weight
Not available
Vapor Density
Not applicable
Physical State Data
liquid
Partition Coefficient
Not applicable
Odor Threshold
Not applicable
Freezing Point
Not available
State Under Standard Conditions
Not available
Cloud Point
Not available
Evaporation Rate
2.000
Properties Status
Not available
Vapor Pressure
2 332 Pa
Softening Point
Not available
Solubility In Fat
Not available
Solidification Point
Not available
Relative Evaporation Rate
Not available
Crystallisation Point
Not available
Solubility
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

If necessary, use with sufficient exhaust ventilation.

Hand Protection

Handling with nitril-gloves (EN 374). Breakthrough time: >480 Material thickness: 0,35 mm. Thoroughly check gloves before use. Take of the gloves properly without touching the outside with your bare hands. The manufacturer of the protective gloves has to be consulted about the suitability for a specific work station.

Eye Protection

Tight-fitting safety goggles. Wear a face shield and protective suit in case of exceptional processing problems.

Respiratory Protection

Respiratory protection is not required. Use ABEK type gas masks in case of irritating exposure.

Skin/Body Protection

Wear impermeable clothing. The type of protective equipment depends on the concentration and amount of hazardous substances at the work station in question.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for ECO Interior 10?

The signal word for this substance is "no signal word".

What is the physical form of ECO Interior 10?

ECO Interior 10 is a liquid appearing as liquid . It has characteristic odor.

What is ECO Interior 10 used for?

Interior cleaner for professional use (AISE_SUMI_PW_8a_2; AISE_SUMI_PW_10_1; AISE_SUMI_PW_11_1; AISE_SUMI_PW_19_1)

What is the melting point of ECO Interior 10?

The melting point is 0 C and the boiling point is 100 C 199 C.