NextSDS Logo
Safety Data Sheet EN

Realube PE Wax LFW

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Realube PE Wax LFW

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Lubricant

Manufacturers & Suppliers

R

Reagens UK Ltd

manufacturer

Unit 7 St Georges Court, Altrincham Business Park, Altrincham, Cheshire, WA14 5UA

0161 929 7222

R

Reagens UK Ltd

manufacturer

+39 051-6639111

Emergency Contacts

Reagens UK Ltd

+39-051-6639258 (24 h)

24 h

Regional Medicines and Poisons Information Centre NI

844 892 0111 (24 h)

24 h

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

For the wording of the listed hazard phrases refer to section 16.

Notes

Dangerous components: Void

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

Call a doctor immediately.

Immediate Medical Attention

In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, extinguishing powder or water spray. Use fire extinguishing methods suitable to surrounding conditions.

Unsuitable media

Water with full jet

Specific hazards

In case of fire and/or explosion do not breathe fumes.

Firefighter Protection

Do not inhale explosion gases or combustion gases.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Keep contaminated washing water and dispose of appropriately. Do not allow to penetrate the ground/soil.

Cleanup methods

Pick up mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Dust explosion hazard. Avoid the accumulation of electrostatic charges. When using do not eat or drink. When using do not smoke. Avoid contact with skin and eyes.

Storage

Keep container tightly closed. Keep container dry. Keep away from food, drink and animal feedingstuffs.

Hygiene

When using do not eat or drink. When using do not smoke. Avoid contact with skin and eyes.

Fire prevention

Avoid the accumulation of electrostatic charges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure good ventilation/exhaustion at the workplace.

Hands

Protective gloves for chemical risk are not indispensable. However it is recommended to use protective gloves against chemical risks according to EN 374 when handling. The glove should be chosen based on the specific conditions of use; the material, the thickness and the passage time must be selected along with the supplier. The determined penetration times according to EN 16523-1:2015 are not performed under practical conditions. Therefore a maximum wearing time, which corresponds to 50% of the penetration time, is recommended.

Eyes

Safety glasses

Respiratory

dust filter

Environmental

Do not allow product to reach sewage system or any water course. Do not allow to penetrate the ground/soil.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility In Fat
---
Upper Explosive Limit
---
Cloud Point
---
Explosive Limits
---
Auto Ignition Temperature
---
Physical State Data
solid
Molecular Weight
---
Odor
Characteristic
Vapor Density
Not applicable.
Dynamic Viscosity
Not applicable.
Ph
Not applicable.
Solubility In Water
Insoluble.
Properties Status
---
Solidification Point
---
Odor Threshold
Not determined.
Flammability
Not determined.
State Under Standard Conditions
---
Softening Point
---
Appearance
Powder
Decomposition Temperature
Not determined.
Form
Powder
Voc Content
---
Relative Evaporation Rate
---
Melting Point
Undetermined.
Metal Corrosion
---
Lower Explosive Limit
---
Kinematic Viscosity
Not applicable.
Flash Point
Not applicable.
Relative Density
Not determined.
Freezing Point
Undetermined.
Evaporation Rate
Not applicable.
Colour Intensity
---
Boiling Point
Undetermined.
Bulk Density
0.5 g/cc
Vapor Pressure
---
Colour
White
Density
Not determined.
Solubility
---
Physical State
Powder
Partition Coefficient
Not determined.
Crystallisation Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Smaller quantities can be disposed of with household waste.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Void
Shipping Name
Void
Transport Class
Void
Packing Group
Void
ADR

Not applicable.

IMDG

Not applicable.

IATA

Not applicable.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Realube PE Wax LFW?

The signal word is no signal word.

What is the physical form of Realube PE Wax LFW?

Realube PE Wax LFW is a powder appearing as powder with white color. It has characteristic odor.

What is Realube PE Wax LFW used for?

Lubricant

What is the melting point of Realube PE Wax LFW?

The melting point is Undetermined. and the boiling point is Undetermined..