Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
CGS 8525 all colors
Product Code
CGS 8525 SC

Regulatory Identifiers

CAS Number
N/A

Identified Uses

polyvinyl chloride-based compound for the production of cables, profiles, tubes, sheets and moldings.

Manufacturers & Suppliers

I

INDUSTRIE GENERALI SPA

manufacturer

via Delle Orchidee 12, 20020 Vanzaghello (Mi) ITALIA

+390331226220

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

The product does not contain substances classified as being hazardous to human health or the environment pursuant to the provisions Regulation (EU) 1272/2008 (CLP) (and subsequent amendments and supplements) in such quantities as to require the statement.

**INDUSTRIE GENERALI SPA** Revision nr. 3 Dated 06/08/2021 **CGS 8525 SC - all colors** Printed on 06/08/2021 Page n. 2/11 Replaced revision:2 (Dated: 12/07/2018)

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

if the gases released during the production process are inhaled, take the subject outdoors and seek medical advice.

Skin contact

the product does not require any particular precautions. Wash well in the event of high exposure and/or significant contamination.

Eye contact

wash immediately with water for at least 10 minutes using an eyebath.

Symptoms: The greatest hazard is the physical impact that can be caused by a granule on the surface of the eye, rather the chemical reactivity of its components.

Ingestion

if accidentally swallowed, seek medical advice and show the doctor this safety datasheet.

Immediate Medical Attention

Immediate intervention by a doctor: no data is available suggesting specific requirements.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, water sprays, powder, foam or carbon dioxide (CO2) extinguishers.

Specific hazards

PVC compound is slightly flammable and self-extinguishing. If a flame is brought close to it, it catches fire, however if the flame is moved away, combustion rapidly ceases.

Instructions

Cool nearby containers using jets of water.

Firefighter Protection

As for any fire, wear self-contained, pressurised breathing apparatus, approved according to UNI standards (or equivalent) and full protective gear.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Collect it using mechanical equipment and remove any traces of dust; recover or dispose of material in compliance with applicable regulations. It may be advisable to wash with water any surfaces contaminated with traces of dust, without contaminating waste water.

Environmental

Restrict leakage and avoid release into the environment and waste water.

Cleanup methods

collect it using mechanical equipment and remove any traces of dust; wash with water any surfaces contaminated with traces of dust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

The product must be used by suitable qualified personnel, in compliance with the standards of good practice for the situation in which it is used. Avoid inhaling any dust present, avoid contact with the skin and eyes, restrict the spread of dust and fumes as far as possible. Use protective gloves and comply with hygiene regulations when handling the material.

Storage

There are no particular hazards linked to storage conditions.

Hygiene

Use protective gloves and comply with hygiene regulations when handling the material.

Fire prevention

Avoid storage in warehouses for flammable products.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ventilation in the work area should always allow correct capture of process fumes and vapours, so as to prevent continuous exposure of workers.

Hands

wear protective gloves when handling hot materials. It is advisable to wear protective gloves at all times, including during the maintenance and cleaning of lines and equipment. The suitability and durability of gloves depends on how they are used and on the frequency and duration of contact and the chemical resistance and thickness of the material the glove is made of. Always ask suppliers for the technical specifications of their gloves. Worn or contaminated gloves should be replaced.

Eyes

protective goggles should be used when handling products and during cleaning and maintenance work.

Respiratory

if the operating procedures, including maintenance and/or cleaning of lines and equipment, are unable to guarantee the concentration of vapours and airborne particles is kept at a suitable level to protect workers' health, choose respiratory protection devices suited to the particular conditions of use in compliance with applicable regulations. Check the suitability of respiratory protection devices with suppliers. Where filtered breathing apparatus is suitable, use an appropriate mask – filter combination. Select a filter suited to gas and organic vapours in compliance with European standard EN 141 (Gas filters and combined filters).

Skin/Body

wear clothing or normal protective overalls that are resistant to dust or auxiliary product contamination.

Environmental

Release by ventilation equipment or from work processes should be monitored to make sure they comply with the provisions of environmental regulations. In some cases, fumes will have to be washed, waste water processed, filters added or technical modifications made to processing equipment to reduce emissions to acceptable levels that comply with the standards indicated in the emissions authorisation document. Avoid the presence of compounds in the waste water discharged from drainage abatement systems.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Pressure
Not applicable
Partition Coefficient
Not applicable
Flash Point
Not applicable
Melting Point
> 90 °C
Physical State
solid in granules
Physical State Data
solid
Solubility In Water
insoluble in water
Upper Explosive Limit
Not applicable
Solubility In Fat
---
Bulk Density
0,6-0,8gr/cm3
Form
granules
Colour Intensity
---
Auto Ignition Temperature
> 350 °C
Vapor Density
Not applicable
Decomposition Temperature
>200°C
Relative Evaporation Rate
---
State Under Standard Conditions
---
Molecular Weight
---
Relative Density
>1
Freezing Point
> 90 °C
Ph
Not applicable
Cloud Point
---
Softening Point
---
Flammability
not relevant
Solubility
insoluble in water
Evaporation Rate
Not applicable
Density
---
Dynamic Viscosity
---
Solidification Point
---
Properties Status
---
Lower Explosive Limit
Not applicable
Metal Corrosion
---
Kinematic Viscosity
---
Explosive Limits
---
Boiling Point
Not applicable
Crystallisation Point
---
Colour
according to pigmentation
Appearance
solid in granules
Odor
mild
Odor Threshold
NR
Voc Content
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

The product is stable and does not cause hazardous reactions in normal conditions of use.

Hazardous reactions

The product does not cause hazardous reactions in normal conditions of use.

Avoid

The product only starts to breakdown at a temperature of about 200°C/392°F.

Incompatible

Avoid contact with strong oxidising agents and bases.

Decomposition

Thermal decomposition depends to a great extent on process conditions. When this material is subject to combustion or thermal or oxidative deterioration, a complex mixture of airborne solids and gases forms, which includes hydrochloric acid, carbon monoxide, carbon dioxide, ammonia and other organic compounds.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

recover and recycle the preparation and any articles made with it. Dispose of the product in compliance with applicable regulations.

Disposal

follow applicable regulations, by allocating the correct European Waste Code and contacting a firm authorised to dispose of industrial waste.

Waste Codes

160119 plastic EWC
170203 plastic EWC
170411 cable EWC
191204 plastic and rubber EWC
070213 plastic waste EWC
120105 plastic filings and shavings EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not applicable
Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for CGS 8525 all colors?

The signal word is no signal word.

What is the physical form of CGS 8525 all colors?

CGS 8525 all colors is a solid in granules appearing as solid in granules with according to pigmentation color. It has mild odor.

What is the solubility of CGS 8525 all colors?

insoluble in water

What is CGS 8525 all colors used for?

polyvinyl chloride-based compound for the production of cables, profiles, tubes, sheets and moldings.

What is the melting point of CGS 8525 all colors?

The melting point is > 90 °C and the boiling point is Not applicable.