Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- CGS 8525 all colors
- Product Code
- CGS 8525 SC
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
polyvinyl chloride-based compound for the production of cables, profiles, tubes, sheets and moldings.
Manufacturers & Suppliers
INDUSTRIE GENERALI SPA
manufacturer
via Delle Orchidee 12, 20020 Vanzaghello (Mi) ITALIA
+390331226220
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
The product does not contain substances classified as being hazardous to human health or the environment pursuant to the provisions Regulation (EU) 1272/2008 (CLP) (and subsequent amendments and supplements) in such quantities as to require the statement.
**INDUSTRIE GENERALI SPA** Revision nr. 3 Dated 06/08/2021 **CGS 8525 SC - all colors** Printed on 06/08/2021 Page n. 2/11 Replaced revision:2 (Dated: 12/07/2018)
First Aid Measures
Emergency procedures for chemical exposure incidents
if the gases released during the production process are inhaled, take the subject outdoors and seek medical advice.
the product does not require any particular precautions. Wash well in the event of high exposure and/or significant contamination.
wash immediately with water for at least 10 minutes using an eyebath.
Symptoms: The greatest hazard is the physical impact that can be caused by a granule on the surface of the eye, rather the chemical reactivity of its components.
if accidentally swallowed, seek medical advice and show the doctor this safety datasheet.
Immediate Medical Attention
Immediate intervention by a doctor: no data is available suggesting specific requirements.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water, water sprays, powder, foam or carbon dioxide (CO2) extinguishers.
PVC compound is slightly flammable and self-extinguishing. If a flame is brought close to it, it catches fire, however if the flame is moved away, combustion rapidly ceases.
Cool nearby containers using jets of water.
Firefighter Protection
As for any fire, wear self-contained, pressurised breathing apparatus, approved according to UNI standards (or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Collect it using mechanical equipment and remove any traces of dust; recover or dispose of material in compliance with applicable regulations. It may be advisable to wash with water any surfaces contaminated with traces of dust, without contaminating waste water.
Restrict leakage and avoid release into the environment and waste water.
collect it using mechanical equipment and remove any traces of dust; wash with water any surfaces contaminated with traces of dust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The product must be used by suitable qualified personnel, in compliance with the standards of good practice for the situation in which it is used. Avoid inhaling any dust present, avoid contact with the skin and eyes, restrict the spread of dust and fumes as far as possible. Use protective gloves and comply with hygiene regulations when handling the material.
There are no particular hazards linked to storage conditions.
Use protective gloves and comply with hygiene regulations when handling the material.
Avoid storage in warehouses for flammable products.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ventilation in the work area should always allow correct capture of process fumes and vapours, so as to prevent continuous exposure of workers.
wear protective gloves when handling hot materials. It is advisable to wear protective gloves at all times, including during the maintenance and cleaning of lines and equipment. The suitability and durability of gloves depends on how they are used and on the frequency and duration of contact and the chemical resistance and thickness of the material the glove is made of. Always ask suppliers for the technical specifications of their gloves. Worn or contaminated gloves should be replaced.
protective goggles should be used when handling products and during cleaning and maintenance work.
if the operating procedures, including maintenance and/or cleaning of lines and equipment, are unable to guarantee the concentration of vapours and airborne particles is kept at a suitable level to protect workers' health, choose respiratory protection devices suited to the particular conditions of use in compliance with applicable regulations. Check the suitability of respiratory protection devices with suppliers. Where filtered breathing apparatus is suitable, use an appropriate mask – filter combination. Select a filter suited to gas and organic vapours in compliance with European standard EN 141 (Gas filters and combined filters).
wear clothing or normal protective overalls that are resistant to dust or auxiliary product contamination.
Release by ventilation equipment or from work processes should be monitored to make sure they comply with the provisions of environmental regulations. In some cases, fumes will have to be washed, waste water processed, filters added or technical modifications made to processing equipment to reduce emissions to acceptable levels that comply with the standards indicated in the emissions authorisation document. Avoid the presence of compounds in the waste water discharged from drainage abatement systems.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
The product is stable and does not cause hazardous reactions in normal conditions of use.
The product does not cause hazardous reactions in normal conditions of use.
The product only starts to breakdown at a temperature of about 200°C/392°F.
Avoid contact with strong oxidising agents and bases.
Thermal decomposition depends to a great extent on process conditions. When this material is subject to combustion or thermal or oxidative deterioration, a complex mixture of airborne solids and gases forms, which includes hydrochloric acid, carbon monoxide, carbon dioxide, ammonia and other organic compounds.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
recover and recycle the preparation and any articles made with it. Dispose of the product in compliance with applicable regulations.
follow applicable regulations, by allocating the correct European Waste Code and contacting a firm authorised to dispose of industrial waste.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not applicable
- Shipping Name
- Not applicable
- Transport Class
- Not applicable
- Packing Group
- Not applicable
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for CGS 8525 all colors?
The signal word is no signal word.
What is the physical form of CGS 8525 all colors?
CGS 8525 all colors is a solid in granules appearing as solid in granules with according to pigmentation color. It has mild odor.
What is the solubility of CGS 8525 all colors?
insoluble in water
What is CGS 8525 all colors used for?
polyvinyl chloride-based compound for the production of cables, profiles, tubes, sheets and moldings.
What is the melting point of CGS 8525 all colors?
The melting point is > 90 °C and the boiling point is Not applicable.