NextSDS Logo
Safety Data Sheet EN

HAKU 5196

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HAKU 5196
Product Code
411051960000

Regulatory Identifiers

CAS Number
N/A
UFI Code
6RM0-R0ET-900R-6SAC

Identified Uses

PC9a - Coatings and paints, thinners, paint removers; PC35 - Washing and cleaning products (including solvent based products); SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites; PROC7 - Industrial spraying; PROC8a - Transfer of substance or preparation (charging/discharging) from/to vessels/large containers at non dedicated facilities; PROC8b - Transfer of substance or preparation (charging/discharging) from/to vessels/large containers at dedicated facilities; PROC10 - Roller application or brushing; PROC11 - Non industrial spraying; PROC13 - Treatment of articles by dipping and pouring; PROC19 - Hand-mixing with intimate contact and only PPE available; PROC28 - Manual maintenance (cleaning and repair) of machinery; ERC2 - Formulation of preparations (mixtures); ERC4 - Industrial use of processing aids in processes and products, not becoming part of articles

Manufacturers & Suppliers

Kluthe Benelux B.V. logo

Kluthe Benelux B.V.

manufacturer

Produktieweg 8, NL-2404 Alphen aan den Rijn

+31 172/516 000

http://www.kluthe.com

Emergency Contacts

CHEMTREC

+44 20 3885 0382

24h/7/365

CHEMTREC

0800 1817059

CHEMTREC

+31 85 888 0596

CHEMTREC

+34 931768511

CHEMTREC

+45 69 91 85 73

CHEMTREC

+48 22 398 80 29

CHEMTREC

+386 1 888 80 16

CHEMTREC

+44 20 3807 3798

CHEMTREC

+43 1 3649237

CHEMTREC

+32 2 808 32 37

CHEMTREC

+351 308 801 773

CHEMTREC

+46 8 525 034 03

CHEMTREC

+420 228 880 039

CHEMTREC

+36 1 808 8425

CHEMTREC

+41 435081970

CHEMTREC

+33 9 75 18 14 07

CHEMTREC

+39 02 4555 7031

CHEMTREC

+358 9 42419014

CHEMTREC

+421 2/330 579 72

CHEMTREC

+40 376 300 026

Europe

112

Giftinformationszentrale

+43 1 406 43 43

NTIC

+421 2 5477 4166

ETTSZ

+36 80 201 199

ETTSZ

+36 1 476 6464

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Asp. Tox. Cat. 1 H304
STOT SE Cat. 3 H336
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H225 Highly flammable liquid and vapor.
H304 May be fatal if swallowed and enters airways.
H336 May cause drowsiness or dizziness.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking
P261 Avoid breathing dust/fume/gas/mist/vapors/spray
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER or doctor
P312 Call a POISON CENTER or doctor if you feel unwell
P331 Do NOT induce vomiting
P370 + P378 In case of fire: Use dry chemical, CO2, water spray or alcohol-resistant foam to extinguish

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C9 - 10, n.alkanes, i-alkanes, cyclics, < 2% aromates EC: 927-241-2 --- 75 - 100% Yes
Propylene glycol monomethyl ether EC: 203-539-1 107-98-2 10 - 25% Yes

This product does not contain candidate substances of very high concern at a concentration >=0.1% (Regulation (EC) No. 1907/2006 (REACH), Article 59)

Notes

Acute Toxicity Estimate: If LD50/LC50 data is not available or does not correspond to the classification category, then the appropriate conversion value from CLP Annex I, Table 3.1.2, is used to calculate the acute toxicity estimate (ATEmix) for classifying a mixture based on its components

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. Aspiration into lungs can produce severe lung damage. If breathing has stopped, give artificial respiration. Get medical attention immediately. Avoid direct contact with skin. Use barrier to give mouth-to-mouth resuscitation. If breathing is difficult, (trained personnel should) give oxygen. Get immediate medical attention. Delayed pulmonary edema may occur.

Symptoms: Difficulty in breathing. Coughing and/ or wheezing. Dizziness. Inhalation of high vapor concentrations may cause symptoms like headache, dizziness, tiredness, nausea and vomiting.

Skin contact

Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes.

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Keep eye wide open while rinsing. Do not rub affected area.

Ingestion

Do NOT induce vomiting. Rinse mouth. Never give anything by mouth to an unconscious person. If vomiting occurs spontaneously, keep head below hips to prevent aspiration. Get immediate medical attention.

Symptoms: ASPIRATION HAZARD IF SWALLOWED - CAN ENTER LUNGS AND CAUSE DAMAGE.

Immediate Medical Attention

Immediate medical attention is required.

Medical Treatment

Because of the danger of aspiration, emesis or gastric lavage should not be employed unless the risk is justified by the presence of additional toxic substances.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Dry chemical. Carbon dioxide (CO2). Water spray. Alcohol resistant foam.

Unsuitable media

Do not scatter spilled material with high pressure water streams.

Specific hazards

Risk of ignition. Keep product and empty container away from heat and sources of ignition. In the event of fire, cool tanks with water spray.

Instructions

In the event of fire, cool tanks with water spray.

Firefighter Protection

Firefighters should wear self-contained breathing apparatus and full firefighting turnout gear. Use personal protection equipment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate personnel to safe areas. Keep people away from and upwind of spill/leak. Do not touch or walk through spilled material.

Environmental

Prevent further leakage or spillage if safe to do so. Prevent product from entering drains.

Cleanup methods

Take precautionary measures against static discharges. Dam up. Soak up with inert absorbent material. Pick up and transfer to properly labeled containers.

Materials: inert absorbent material

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use personal protection equipment. Avoid contact with skin and eyes. Avoid breathing vapors or mists. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Use grounding and bonding connection when transferring this material to prevent static discharge, fire or explosion. Use with local exhaust ventilation. Use spark-proof tools and explosion-proof equipment. Keep in an area equipped with sprinklers. Use according to package label instructions. Handle in accordance with good industrial hygiene and safety practice. In case of insufficient ventilation, wear suitable respiratory equipment.

Storage

Keep containers tightly closed in a dry, cool and well-ventilated place. Keep away from heat, sparks, flame and other sources of ignition (i.e., pilot lights, electric motors and static electricity). Keep in properly labeled containers. Do not store near combustible materials. Keep in an area equipped with sprinklers. Store in accordance with the particular national regulations. Store in accordance with local regulations. Store locked up. Keep out of the reach of children. Store away from other materials.

Hygiene

Do not eat, drink or smoke when using this product. Contaminated work clothing should not be allowed out of the workplace. Regular cleaning of equipment, work area and clothing is recommended. Wash hands before breaks and immediately after handling the product.

Fire prevention

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Use grounding and bonding connection when transferring this material to prevent static discharge, fire or explosion. Use spark-proof tools and explosion-proof equipment. Keep in an area equipped with sprinklers.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Showers, eyewash stations, and ventilation systems.

Hands

Wear suitable gloves. Impervious gloves. NBR (Nitrile rubber), Glove thickness: 0.5 mm, Break through time: >=480 min.

Eyes

Tight sealing safety goggles.

Respiratory

No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required. Recommended Filter Type: Filtering device (full mask or mouthpiece) with filter: ABEK; 2P3

Skin/Body

Wear suitable protective clothing. Long sleeved clothing. Chemical resistant apron. Antistatic boots.

Environmental

No information available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid
Colour
colorless
Colour Intensity
---
Form
---
Odor
characteristic
Odor Threshold
Not established
Ph
Not applicable
Melting Point
Not established
Boiling Point
120 - 165 °C
Flash Point
~ 21 °C
Freezing Point
---
Softening Point
No information available
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not established
Vapor Pressure
1.13 kPa
Vapor Density
---
Relative Density
Not established
Bulk Density
no data available
Density
~ 0.767 - 0.797 g/cm3
Flammability
~
Upper Explosive Limit
9 Vol%
Lower Explosive Limit
0.7 Vol%
Explosive Limits
---
Auto Ignition Temperature
250 °C
Decomposition Temperature
not relevant
Solubility
---
Partition Coefficient
Not established
Solubility In Water
< 20.6 %
Solubility In Fat
---
Molecular Weight
No information available
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Not applicable
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No information available.

Hazardous reactions

None under normal processing.

Avoid

Heat, flames and sparks.

Incompatible

None known based on information supplied.

Decomposition

None known based on information supplied.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.

Disposal

Should not be released into the environment.

Waste Codes

14 06 03* other solvents and solvent mixtures EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1993
Shipping Name
FLAMMABLE LIQUID, N.O.S.
Transport Class
3
Packing Group
II
IMDG

274

IATA

ERG Code 3H

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HAKU 5196?

The signal word is danger.

What is the physical form of HAKU 5196?

HAKU 5196 is a liquid appearing as liquid with colorless color. It has characteristic odor.

What is HAKU 5196 used for?

PC9a - Coatings and paints, thinners, paint removers; PC35 - Washing and cleaning products (including solvent based products); SU3 - Industrial uses: Uses of substances as such or in preparations at industrial sites; PROC7 - Industrial spraying; PROC8a - Transfer of substance or preparation (charging/discharging) from/to vessels/large containers at non dedicated facilities; PROC8b - Transfer of substance or preparation (charging/discharging) from/to vessels/large containers at dedicated facilities; PROC10 - Roller application or brushing; PROC11 - Non industrial spraying; PROC13 - Treatment of articles by dipping and pouring; PROC19 - Hand-mixing with intimate contact and only PPE available; PROC28 - Manual maintenance (cleaning and repair) of machinery; ERC2 - Formulation of preparations (mixtures); ERC4 - Industrial use of processing aids in processes and products, not becoming part of articles

What are the hazard statements for HAKU 5196?

This substance has 4 hazard statements:

  • H225: Highly flammable liquid and vapor.
  • H304: May be fatal if swallowed and enters airways.
  • H336: May cause drowsiness or dizziness.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of HAKU 5196?

The melting point is Not established and the boiling point is 120 - 165 °C.