NextSDS Logo
Safety Data Sheet EN

Berasit Linienmarkierer 600ml

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Berasit Linienmarkierer 600ml

Regulatory Identifiers

CAS Number
N/A

Identified Uses

SU21 Consumer uses: Private households / general public / consumers; SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen); PC9a Coatings and paints, thinners, paint removers; Application of the substance / the mixture: Lacquer

Manufacturers & Suppliers

B

BERASIT GmbH + Co. KG

manufacturer

Lademannbogen 65, 22339 Hamburg

Emergency Contacts

Emergency Contact

+49 (0)40 53 80 96 611

Only during the office hours!

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
STOT SE Cat. 3 H336
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H222 Extremely flammable aerosol. Pressurised container: May burst if heated.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H336 May cause drowsiness or dizziness.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P260 Do not breathe spray.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/122 °F.
P501 Dispose of contents / container in accordance with regional regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
propane EC: 200-827-9 74-98-6 12.5 - 20% Yes
butane EC: 203-448-7 106-97-8 12.5 - 20% Yes
ethyl acetate EC: 205-500-4 141-78-6 12.5 - 20% Yes
Naphtha (petroleum), hydrotreated light EC: 265-151-9 64742-49-0 5 - 10% Yes
Hydrocarbons, C6-C7, Isoalkane,Cyclene, <5% n-Hexane EC: 926-605-8 --- 5 - 10% Yes
isobutane EC: 200-857-2 75-28-5 5 - 10% Yes
Hydrocarbons EC: 921-024-6 --- 2.5 - 5% Yes
Kohlenwasserstoffe, C6, Isoalkane, < 5% n-Hexan EC: 931-254-9 --- 2.5 - 5% Yes
Hydrocarbons EC: 927-510-4 --- 2.5 - 5% Yes
2-methoxy-1-methylethyl acetate EC: 203-603-9 108-65-6 2.5% Yes
n-hexane EC: 203-777-6 110-54-3 0.5% Yes
cyclohexane EC: 203-806-2 110-82-7 0.5% Yes

The content of Benzene (EINECS-Nr. 200-753-7) in the ingredients is less than 0,1% (Note P Annex 1A 1272/2008 EU), so the classification as carcinogen need not to apply.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of unconsciousness place patient stably in side position for transportation.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

Drink plenty of water and provide fresh air. Call for a doctor immediately.

Immediate Medical Attention

Call for a doctor immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions.

Specific hazards

During heating or in case of fire poisonous gases are produced.

Firefighter Protection

Mouth respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Mount respiratory protective device. Wear protective equipment. Keep unprotected persons away.

Environmental

Inform respective authorities in case of seepage into water course or sewage system. Do not allow to enter sewers/ surface or ground water.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep respiratory protective device available.

Storage

Keep container tightly sealed. Observe official regulations on storing packagings with pressurised containers.

Fire prevention

Keep ignition sources away - Do not smoke.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

In case of contact with spray dust protective gloves made of butyl should be used (min. 0.4 mm thick), e.g. KCL Camatril, article no. 898 or similar products. Solvent resistant gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Butyl rubber, BR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: Butyl rubber gloves with a thickness of 0.4 mm are resistant to: Acetone: 480 min, Butyl acetate: 60 min, Ethyl acetate: 170 min, Xylene: 42 min. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed goggles

Respiratory

Filter AX. Not necessary if room is well-ventilated. In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Auto Ignition Temperature
365°C (689 °F)
Crystallisation Point
---
Physical State
Aerosol
Odor
Characteristic
Cloud Point
---
Odor Threshold
Not determined.
Solubility In Water
Not miscible or difficult to mix.
Freezing Point
Undetermined.
Explosive Limits
---
Ph
Not determined.
Kinematic Viscosity
Not determined.
Boiling Point
Not applicable, as aerosol.
Properties Status
---
Softening Point
---
Lower Explosive Limit
1.5 Vol %
Solubility
---
Decomposition Temperature
Not determined.
Relative Evaporation Rate
---
Solidification Point
---
Solubility In Fat
---
Flammability
Not applicable.
Vapor Pressure
8,300 hPa (6,225 mm Hg)
Dynamic Viscosity
Not determined.
Vapor Density
Not determined.
State Under Standard Conditions
---
Density
0.82 g/cm³ (6.843 lbs/gal)
Appearance
---
Metal Corrosion
---
Form
Aerosol
Evaporation Rate
Not applicable.
Voc Content
665.6 g/l
Colour
According to product specification
Colour Intensity
---
Upper Explosive Limit
10.9 Vol %
Partition Coefficient
Not determined.
Physical State Data
aerosol
Melting Point
Undetermined.
Molecular Weight
---
Bulk Density
---
Relative Density
Not determined.
Flash Point
Not applicable, as aerosol.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed together with household garbage. Do not allow product to reach sewage system.

Disposal

Must not be disposed together with household garbage.

Waste Codes

08 01 11* waste paint and varnish containing organic solvents or other hazardous substances EWC
15 01 04 metallic packaging EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1950
Shipping Name
AEROSOLS
Transport Class
2
Packing Group
not regulated
ADR

Warning: Gases.

IMDG

Warning: Gases.

IATA

Warning: Gases.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Berasit Linienmarkierer 600ml?

The signal word is danger.

What is the physical form of Berasit Linienmarkierer 600ml?

Berasit Linienmarkierer 600ml is a aerosol with according to product specification color. It has characteristic odor.

What is Berasit Linienmarkierer 600ml used for?

SU21 Consumer uses: Private households / general public / consumers; SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen); PC9a Coatings and paints, thinners, paint removers; Application of the substance / the mixture: Lacquer

What are the hazard statements for Berasit Linienmarkierer 600ml?

This substance has 5 hazard statements:

  • H222: Extremely flammable aerosol. Pressurised container: May burst if heated.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H336: May cause drowsiness or dizziness.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of Berasit Linienmarkierer 600ml?

The melting point is Undetermined. and the boiling point is Not applicable, as aerosol..