Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- QD® Contact Cleaner
- Product Code
- 03130 (Item# 1003407)
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Electronic cleaner
Uses advised against
None known.
Manufacturers & Suppliers
CRC Industries, Inc.
manufacturer
885 Louis Dr., Warminster, PA 18974 US
215-674-4300
http://www.crcindustries.com
Emergency Contacts
CHEMTREC
800-424-9300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS04
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| naphtha (petroleum), hydrotreated light | 64742-49-0 | 30 - 40% | No |
| 1,1-difluoroethane | 75-37-6 | 20 - 30% | No |
| n-heptane | 142-82-5 | 10 - 20% | No |
| 3-methylhexane | 589-34-4 | 5 - 10% | No |
| methylcyclohexane | 108-87-2 | 5 - 10% | No |
| 2,2,4-trimethylpentane | 540-84-1 | 3 - 5% | No |
| 2-methylhexane | 591-76-4 | 3 - 5% | No |
| 2,3-dimethylpentane | 565-59-3 | 1 - 3% | No |
| 3-ethylpentane | 617-78-7 | 1 - 3% | No |
| 3,3-dimethylpentane | 562-49-2 | 1% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a poison center or doctor/physician if you feel unwell.
Remove contaminated clothing. Wash with plenty of soap and water. If skin irritation occurs: Get medical advice/attention. Wash contaminated clothing before reuse.
Symptoms: Skin irritation. May cause redness and pain.
Rinse with water. Get medical attention if irritation develops and persists.
Call a physician or poison control center immediately. Rinse mouth. Do not induce vomiting. If vomiting occurs, keep head low so that stomach content doesn't get into the lungs.
Symptoms: Nausea, vomiting.
Immediate Medical Attention
Provide general supportive measures and treat symptomatically. Keep victim under observation.
Medical Treatment
Provide general supportive measures and treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water fog. Foam. Carbon dioxide (CO2). Dry chemical powder, carbon dioxide, sand or earth may be used for small fires only.
Do not use water jet as an extinguisher, as this will spread the fire.
Contents under pressure. Pressurized container may rupture when exposed to heat or flame. This product is a poor conductor of electricity and can become electrostatically charged. If sufficient charge is accumulated, ignition of flammable mixtures can occur. Static electricity accumulation may be significantly increased by the presence of small quantities of water or other contaminants. Material will float and may ignite on surface of water. During fire, gases hazardous to health may be formed.
In case of fire: Stop leak if safe to do so. Move containers from fire area if you can do so without risk. Containers should be cooled with water to prevent vapor pressure build up. Use standard firefighting procedures and consider the hazards of other involved materials. In the event of fire and/or explosion do not breathe fumes.
Firefighter Protection
Firefighters must use standard protective equipment including flame retardant coat, helmet with face shield, gloves, rubber boots, and in enclosed spaces, SCBA.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep unnecessary personnel away. Keep people away from and upwind of spill/leak. Keep out of low areas. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing.
Avoid release to the environment. Use appropriate containment to avoid environmental contamination.
Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.
Materials: absorbent material (e.g. cloth, fleece)
Related Products
Similar products with comparable safety profiles
QD® Contact Cleaner
---
CO Contact Cleaner
---
Contact Cleaner Lubricant
---
NC CONTACT CLEANER
---
WD-40® Specialist® Fast Drying Contact Cleaner / WD-40® Specialist® CONTACT CLEANER
---
SqueekyKleen™ Communications Cleaner
---
Q-Connect Surface & Whiteboard Cleaning Fluid
---
MOTIP CONTACT CLEANER 500 ML
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Minimize fire risks from flammable and combustible materials (including combustible dust and static accumulating liquids) or dangerous reactions with incompatible materials. Pressurized container: Do not pierce or burn, even after use. Do not use if spray button is missing or defective. Do not spray on a naked flame or any other incandescent material. Do not smoke while using or until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill, grind, or expose containers to heat, flame, sparks, or other sources of ignition. Use caution around energized equipment. The metal container will conduct electricity if it contacts a live source. This may result in injury to the user from electrical shock and/or flash fire. Avoid contact with eyes, skin, and clothing. Avoid prolonged exposure. Use only in well-ventilated areas. Wear appropriate personal protective equipment. Wash hands thoroughly after handling. Avoid release to the environment. Observe good industrial hygiene practices.
Level 3 Aerosol. Pressurized container. Protect from sunlight and do not expose to temperatures exceeding 50 °C/122 °F. Do not puncture, incinerate or crush. Do not handle or store near an open flame, heat or other sources of ignition. Store in tightly closed container. Store in a well-ventilated place. Stored containers should be periodically checked for general condition and leakage. Store away from incompatible materials.
Wash hands thoroughly after handling. Observe good industrial hygiene practices.
Minimize fire risks from flammable and combustible materials. Do not smoke while using or until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill, grind, or expose containers to heat, flame, sparks, or other sources of ignition. Avoid spark promoters.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.
Wear protective gloves such as: Polyvinyl alcohol (PVA). Viton/butyl.
Wear safety glasses with side shields (or goggles).
If engineering controls are not feasible or if exposure exceeds the applicable exposure limits, use a NIOSH-approved cartridge respirator with an organic vapor cartridge. Use a self-contained breathing apparatus in confined spaces and for emergencies. Air monitoring is needed to determine actual employee exposure levels.
Wear appropriate chemical resistant clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
The product is stable and non-reactive under normal conditions of use, storage and transport.
No dangerous reaction known under conditions of normal use.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. Contact with incompatible materials.
Strong oxidizing agents.
Carbon oxides.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Collect and reclaim or dispose in sealed containers at licensed waste disposal site.
Collect and reclaim or dispose in sealed containers at licensed waste disposal site.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1950
- Shipping Name
- Aerosols, flammable, Limited Quantity
- Transport Class
- 2.1
- Packing Group
- Not applicable.
Read safety instructions, SDS and emergency procedures before handling.
Read safety instructions, SDS and emergency procedures before handling.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
This product is a "Hazardous Chemical" as defined by the OSHA Hazard Communication Standard, 29 CFR 1910.1200.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for QD® Contact Cleaner?
The signal word is danger.
What is the physical form of QD® Contact Cleaner?
QD® Contact Cleaner is a liquid appearing as colorless with colorless color. It has hydrocarbon-like odor.
What is QD® Contact Cleaner used for?
Electronic cleaner
What are the hazard statements for QD® Contact Cleaner?
This substance has 7 hazard statements:
- H222: Extremely flammable aerosol.
- H280: Contains gas under pressure; may explode if heated.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H336: May cause drowsiness or dizziness.
- H400: Very toxic to aquatic life.
- H410: Very toxic to aquatic life with long lasting effects.
What is the melting point of QD® Contact Cleaner?
The melting point is -195.9 °F (-126.6 °C) estimated and the boiling point is 179.6 °F (82 °C) estimated.