Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Cleaning Solution D
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals, Refer to product literature for further details.
Manufacturers & Suppliers
Roche Diagnostics Limited
manufacturer
Charles Avenue, Burgess Hill, RH15 9RY West Sussex, United Kingdom
+44 1444 256000
Roche Diagnostics Ltd.
Emergency Contacts
Product Safety / Vigilance
+44 (0)808 100 1920
Product Safety / Vigilance
1800 409 564
Roche Diagnostics Ltd.
1800 409 564
NPIS
+44 344 892 0111
NHS Direct in Wales
111
NHS Direct in Wales
+44 845 4647
NHS 111 in England
111
NHS 24 in Scotland
111
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Potassium hydroxide EC: 215-181-3 | 1310-58-3 | 0.5 - 1% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.
If skin irritation persists, call a physician. If on skin, rinse well with water. If on clothes, remove clothes.
Symptoms: Causes skin irritation.
Immediately flush eye(s) with plenty of water. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
Symptoms: Causes serious eye irritation.
Clean mouth with water and drink afterwards plenty of water. Keep respiratory tract clear. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.
Medical Treatment
The first aid procedure should be established in consultation with the doctor responsible for industrial medicine.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
High volume water jet
No information available.
Standard procedure for chemical fires.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Refer to protective measures listed in sections 7 and 8.
Prevent further leakage or spillage if safe to do so. Local authorities should be advised if significant spillages cannot be contained.
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Keep in suitable, closed containers for disposal.
Materials: sand, silica gel, acid binder, universal binder, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not breathe vapours/dust. Avoid contact with skin and eyes. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations.
Keep container tightly closed in a dry and well-ventilated place.
When using do not eat or drink. When using do not smoke. Wash hands before breaks and at the end of workday.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
In case of full contact: Material : Nitrile rubber, Break through time : > 480 min, Glove thickness : 0,11 mm. In case of contact through splashing: Material : Nitrile rubber, Break through time : > 480 min, Glove thickness : 0,11 mm. Remarks: The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
Eye wash bottle with pure water, Tightly fitting safety goggles, Wear face-shield and protective suit for abnormal processing problems.
Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No dangerous reaction known under conditions of normal use.
No decomposition if stored and applied as directed.
No data available
Acids, Strong oxidizing agents
No decomposition if stored and applied as directed.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1814
- Shipping Name
- POTASSIUM HYDROXIDE SOLUTION
- Transport Class
- 8
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Cleaning Solution D?
The signal word is warning.
What is the physical form of Cleaning Solution D?
Cleaning Solution D is a liquid appearing as liquid with colourless color. It has odourless odor.
What is Cleaning Solution D used for?
Laboratory chemicals, Refer to product literature for further details.
What are the hazard statements for Cleaning Solution D?
This substance has 2 hazard statements:
- H315: Causes skin irritation.
- H319: Causes serious eye irritation.
What is the melting point of Cleaning Solution D?
The melting point is No data available and the boiling point is 100 °C.