NextSDS Logo
Safety Data Sheet EN

PARMETOL DF 35

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PARMETOL DF 35

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Preservative

Manufacturers & Suppliers

Schülke & Mayr GmbH logo

Schülke & Mayr GmbH

manufacturer

Robert-Koch-Str. 2, 22851 Norderstedt, Germany

+4940521000

http://www.schuelke.com

Emergency Contacts

Emergency Contact

+49 (0)40 / 52 100 -0

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified na: r-phrases

Hazard Classifications

Skin Corr.
Aquatic Chronic

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Aqueous solution

Chemical Name CAS Number Concentration Hazardous
Mixture of 5-chloro-2-methyl-2H-isothiazol-3-one (CAS 26172-55-4) and 2-methyl-2H-isothiazol-3-one (CAS 2682-20-4) 55965-84-9 0.6 - 0.8% Yes
(Ethylenedioxy)dime thanol EC: 222-720-6 3586-55-8 30 - 50% Yes

Notes

For the full text of the R-phrases mentioned in this Section, see Section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If symptoms persist, call a physician.

Skin contact

Wash off immediately with plenty of water.

Eye contact

In the case of contact with eyes, rinse immediately with plenty of water and seek medical advice.

Ingestion

Do NOT induce vomiting. Rinse mouth with water. Give small amounts of water to drink. Obtain medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Dry powder, Foam, Carbon dioxide (CO2)

Unsuitable media

No information available.

Specific hazards

Decomposition products, see chapter 10

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not flush into surface water or sanitary sewer system. Avoid subsoil penetration.

Cleanup methods

Wipe up with absorbent material (e.g. cloth, fleece). Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).

Materials: cloth, fleece, sand, silica gel, acid binder, universal binder, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only in well-ventilated areas. Handle and open container with care.

Storage

Store in original container. Keep away from heat. Keep away from direct sunlight. Keep container tightly closed. Limited stability - see label on pack

Fire prevention

No special protective measures against fire required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Hand protection : Impervious gloves. Splash protection: disposable nitrile rubber gloves e.g. Dermatril made by KCL or gloves from other manufacturers offering the same protection. Prolonged contact: Butyl rubber gloves e.g. Butoject (>480 Min.) made by KCL or gloves from other manufacturers offering the same protection.

Eyes

Tightly fitting safety goggles

Skin/Body

Take off all contaminated clothing immediately.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid, colourless - light yellow
Colour
colourless - light yellow
Colour Intensity
---
Form
Liquid
Odor
aldehyde like
Odor Threshold
---
Ph
ca.6 - 8 at 1,5 g/l (20 °C)
Melting Point
---
Boiling Point
ca. 100 °C
Flash Point
>100 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
ca.25 hPa at 20 °C
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1,134 - 1,146 g/cm3 at 20 °C
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
at 20 °C in all proportions
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
<15 s at 20 °C
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Hazardous reactions

None reasonably foreseeable.

Decomposition

formaldehyde

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Dispose of as special waste in compliance with local and national regulations. Can be disposed of as a solid waste or burned in a suitable installation subject to local regulations.

Waste Codes

To be determined by waste producer European Waste Catalogue EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1760
Shipping Name
CORROSIVE LIQUID, N.O.S. (5-Chloro-2-methyl-2H-isothiazol-3-one, 2-Methyl-2H-isothiazol-3-one)
Transport Class
8
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The product belongs to at least one of the categories 1 through 11 mentioned in Annex 1 of the Directive 1996/82/EC concerning the control of major accident hazards.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PARMETOL DF 35?

The signal word is na: r-phrases.

What is the physical form of PARMETOL DF 35?

PARMETOL DF 35 is a liquid appearing as liquid, colourless - light yellow with colourless - light yellow color. It has aldehyde like odor.

What is PARMETOL DF 35 used for?

Preservative