NextSDS Logo
Safety Data Sheet EN

Aqueous Urea Solution, AUS 32

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Aqueous Urea Solution, AUS 32
Synonyms
AdBlue®

Regulatory Identifiers

CAS Number
N/A
REACH No.
Not applied for mixture

Identified Uses

The product is a NOₓ-gases reduction agent used in the selective catalytic reduction (SCR) in motor vehicles with a diesel engine.

Uses advised against

Not recommended for other uses than is mentioned.

Manufacturers & Suppliers

G

GreenChem Holding B.V.

manufacturer

Gravinnen van Nassauboulevard 95, 4811 BN BREDA – Netherlands

+31 (0)76 – 581 27 27

G

GreenChem SK, s. r. o.

national supplier

Nobelova 34, 836 05 Bratislava, Slovakia

+421 2 4951 2737

Emergency Contacts

Emergency Contact

112

24 hours service

Národné Toxikologické Informačné Centrum (TIC)

+421 2 5477 4166

24 hour service

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Aqueous Urea Solution (32.5%)

Chemical Name CAS Number Concentration Hazardous
Urea EC: 200-315-5 57-13-6 32.5% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Take out the exposed person to the fresh air.

Skin contact

Wash skin with warm water and soap.

Eye contact

Wash out the eye with plenty of clean water 15 min., seek for medical care.

Ingestion

Drink ca. 2 dcl lukewarm water, do not induce vomiting and seek for medical care.

Immediate Medical Attention

Seek for medical care (for eye contact and ingestion).

Medical Treatment

No information available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Extinguishing media to be selected upon surrounding fire.

Unsuitable media

Flammable materials and extinguishing media which cannot be used for surrounding fire.

Specific hazards

When AdBlue is stored in the GreenChem system tank and the system is in danger of fire or extreme heat, pressure will rise and the vessel may burst.

Instructions

In case of fire, immediately isolate the area by evacuating all personnel from the incident vicinity. Do not take any actions that could pose personal risk or for which you are not trained. Always proceed in accordance with directions given in valid emergency plans.

Firefighter Protection

Irritating substances may be released in thermal combustion, thus a self-contained breathing apparatus is necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment during handling with the product (see Section 8). Avoid contact with eyes, skin and clothing.

Environmental

Prevent release to water resources, sewerage and soil. The product is not classified as hazardous for environment.

Cleanup methods

In case of spilling, rinse the area with plenty of water. Dispose of the remains in a controlled way by flushing them into wastewaters brought to a sewage treatment plant.

Materials: water

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Provide adequate ventilation during manipulation with product and avoid contact with skin and eyes using personal protective equipment. Follow the rules of safe handling of chemicals and basic hygiene habits. Avoid contamination of the product.

Storage

store under common conditions (optimally up to 25 °C).

Hygiene

basic hygiene habits

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure sufficient local ventilation.

Hands

Protective gloves. The breakthrough time: > 8 hours. Suitable glove material: PVC, natural rubber (latex), butyl rubber, nitrile rubber. Material to be avoided: leather.

Eyes

Use protective goggles with side shields when handling the product (e.g. transferring).

Respiratory

In case of insufficient ventilation system, use effective respirator, mask with ammonia-proof filter.

Skin/Body

Wear suitable protective gloves and shoes.

Environmental

Prevent uncontrolled release to environment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

State Under Standard Conditions
---
Solidification Point
---
Voc Content
---
Ph
Max. 10 (10% aqueous liquid)
Crystallisation Point
-11.5 °C
Dynamic Viscosity
Approx. 1.4 mPa.s at 25 °C
Melting Point
Information is not available
Form
---
Solubility
Miscible in water
Lower Explosive Limit
Information is not available
Partition Coefficient
Information is not available
Odor
Slight ammonia-like
Physical State
Liquid
Colour
Clear, colourless
Metal Corrosion
---
Softening Point
---
Properties Status
---
Appearance
---
Freezing Point
---
Relative Density
---
Vapor Pressure
Information is not available
Density
1,087 – 1,093 kg/m³
Bulk Density
---
Solubility In Fat
---
Solubility In Water
Miscible in water
Odor Threshold
---
Molecular Weight
60.06 kg/kmol
Boiling Point
Information is not available
Evaporation Rate
---
Vapor Density
---
Cloud Point
---
Upper Explosive Limit
Information is not available
Physical State Data
liquid
Kinematic Viscosity
Information is not available
Auto Ignition Temperature
Information is not available
Flash Point
Information is not available
Decomposition Temperature
Information is not available
Colour Intensity
---
Explosive Limits
---
Relative Evaporation Rate
---
Flammability
Information is not available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage and handling conditions (see Section 7, handling and storage).

Reactivity

Stable under recommended storage and handling conditions (see Section 7, handling and storage).

Hazardous reactions

When heated, decomposition of products.

Avoid

Heating causes thermal decomposition and the gases formation.

Incompatible

Not know.

Decomposition

NOₓ, NH₃, CO₂

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Depending on the degree and character of contamination, the product is suitable to use for agricultural purposes or for disposal under control by authorized waste contractors (sewage treatment plant).

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Unassigned
Shipping Name
Unassigned
Transport Class
Unassigned
Packing Group
Unassigned
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Performed

Urea does not meet the criteria for hazardous substance classification within the meaning of Regulation (EC) No. 1272/2008 and is assessed to be neither PBT nor vPvB, and therefore exposition assessment is not required, incl. the preparation of exposure scenarios (Art. 14 (4) of Regulation (EC) No. 1907/2006).

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Aqueous Urea Solution, AUS 32 known by?

Aqueous Urea Solution, AUS 32 is also known as: AdBlue®

What is the hazard signal word for Aqueous Urea Solution, AUS 32?

The signal word is no signal word.

What is the physical form of Aqueous Urea Solution, AUS 32?

Aqueous Urea Solution, AUS 32 is a liquid with clear, colourless color. It has slight ammonia-like odor.

What is the solubility of Aqueous Urea Solution, AUS 32?

Miscible in water

What is Aqueous Urea Solution, AUS 32 used for?

The product is a NOₓ-gases reduction agent used in the selective catalytic reduction (SCR) in motor vehicles with a diesel engine.

What is the melting point of Aqueous Urea Solution, AUS 32?

The melting point is Information is not available and the boiling point is Information is not available.