Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Reagent H25-0,02 / H25-0,05 / H25-0,1 / H25-0,2 / H25-0,3 / H25-0,5
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
RLS Wacon GmbH
manufacturer
Eduard- Ahlborn-Straße 1 D 31137 Hildesheim Germany
+49 (0) 5121 28126-0
www.rls-wacon.de
Emergency Contacts
Giftinformationszentrum Nord
+49 (0) 551 19240
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Mixture of substances listed below with nonhazardous additions according to Regulation (EC) No 1272/2008
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ethylenediaminetetraacetic acid dipotassium magnesium salt EC: 239-803-8 | 15708-48-2 | 0.1 - 2.5% | Yes |
| 1,1'-Iminodipropan-2-ol EC: 203-820-9 | 110-97-4 | 10 - 25% | Yes |
| 4-[4-(Dimethylamino)phenylazo]benzenesulfonic acid sodium salt EC: 208-925-3 | 547-58-0 | 0.1 - 2.5% | Yes |
Full text of H-and EUH-phrases see section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air, contact doctor in case of complaints.
Wash immediately with water and soap. Consult doctor in case of complaints.
Rinse opened eye for several minutes under running water. Consult doctor in case of complaints.
Rinse out mouth with water and than drink plenty of water. Turn a person onto their side. Consult doctor in case of complaints.
Immediate Medical Attention
No further relevant information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, powder spray, CO2, alcohol resistant foam.
No further relevant information available.
Firefighter Protection
Use self contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid inhalation of vapors and contact with the product. Avoid skin contact with the product.
Avoid the product to enter ground water, surface and sewers.
Absorb the product with binding materials as sand, universal binders and so on. Dispose the collected material according to regulations. Clean the area carefully with warm water.
Materials: binding materials as sand, universal binders and so on.
Related Products
Similar products with comparable safety profiles
Hydrochloric acid 25% for analysis EMSURE
---
2-Ethylhexanol Pro 25
CAS: 104-76-7
Hydrochloric acid 25%
---
Aquagent, standard solution 0,1%
UFI: VPC0-R05P-K000-S2R8
Hydrochloric acid 15-25% pro analyse
UFI: YM7U-YG06-TEM4-15DH
Sulfuric acid 25% for analysis EMSURE
---
Reagent 1
---
Ammonium hydroxide, 25% NH3
CAS: 1336-21-6
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Close bottle after use. Store only in pristine bottles. Ensure good ventilation at the work place. Prevent formation of aerosols. Do not eat or drink in working areas. Wash your hands after use. Change heavy contaminated clothes. Ensure fresh air at the working place.
Keep bottles sealed. Avoid heat and direct sunlight. Supply fresh air to the storage. Recommended storage temperature 15-25 °C
Do not eat or drink in working areas. Wash your hands after use. Change heavy contaminated clothes.
Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Wear protective gloves. The material of the gloves has to be impermeable and resistant to the product / the substance / the preparation. Due to missing tests no recommendation to the glove material can be given for the product / the preparation / the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of suitable gloves does not only depend on the material but also on further marks of quality and varies from manufacturer to manufacturer. As Product is a preparation of several substances, the resistance of the glove material cannot be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Tightly sealed goggles.
Not required.
Wear protective work clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
React with metals forming hydrogen.
Copper, Aluminium and their alloys.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Disposal must be made according to official national regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not dangerous according to the above specifications.
- Shipping Name
- Not dangerous according to the above specifications.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Reagent H25-0,02 / H25-0,05 / H25-0,1 / H25-0,2 / H25-0,3 / H25-0,5?
The signal word is warning.
What is the physical form of Reagent H25-0,02 / H25-0,05 / H25-0,1 / H25-0,2 / H25-0,3 / H25-0,5?
Reagent H25-0,02 / H25-0,05 / H25-0,1 / H25-0,2 / H25-0,3 / H25-0,5 is a fluid appearing as fluid green with green color. It has characteristic odor.
What is the solubility of Reagent H25-0,02 / H25-0,05 / H25-0,1 / H25-0,2 / H25-0,3 / H25-0,5?
Fully miscible
What is Reagent H25-0,02 / H25-0,05 / H25-0,1 / H25-0,2 / H25-0,3 / H25-0,5 used for?
Reagent for analysis
What are the hazard statements for Reagent H25-0,02 / H25-0,05 / H25-0,1 / H25-0,2 / H25-0,3 / H25-0,5?
This substance has 1 hazard statement:
- H319: Causes serious eye irritation.
What is the melting point of Reagent H25-0,02 / H25-0,05 / H25-0,1 / H25-0,2 / H25-0,3 / H25-0,5?
The melting point is No data available and the boiling point is No data available.