Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- CELLPACK DST
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For in-vitro diagnosis
Uses advised against
No data available.
Manufacturers & Suppliers
SYSMEX LTD
national supplier
Sysmex House Garamonde Drive Wymbush Milton Keynes Buckinghamshire MK8 8DF United Kingdom
+44 (0)333 320 3460
Emergency Contacts
Giftinformationszentrum Nord
+49 (0)551 192 40
DE, EN
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| maleic acid EC: 203-742-5 | 110-16-7 | 2.5% | Yes |
| pyridine-2-thiol 1-oxide, sodium salt EC: 223-296-5 | 3811-73-2 | 0.5% | Yes |
| 1,2-benzisothiazol-3(2H)-one EC: 220-120-9 | 2634-33-5 | 0.1% | Yes |
Notes
Full Text for all H-phrases and EUH-phrases: pls. see section 16 (*,**,***,****) Detailed explanation pls. refer to CLP regulation No. 1272/2008, annex VI, 1.2
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove affected person from the immediate area. Ensure supply of fresh air.
Wash off immediately with soap and water.
Separate eyelids, wash the eyes thoroughly with water (15 min.).
Call a doctor immediately. Do not induce vomiting. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
No data available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam; Extinguishing powder; Carbon dioxide; Water spray jet
High power water jet
In the event of fire, the following can be released: Carbon dioxide (CO2); Carbon monoxide (CO); Sulphur oxides (SxOy); Nitrogen oxides (NOx); chlorine compounds
Firefighter Protection
Use self-contained breathing apparatus. Wear protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Refer to protective measures listed in sections 7 and 8. Ensure adequate ventilation. Avoid contact with skin, eyes and clothing. Do not inhale vapours. Keep away from ignition sources.
Do not discharge into the drains/surface waters/groundwater. Do not discharge into the subsoil/soil.
Take up with absorbent material (e.g., sand, kieselguhr, universal binder). When collected, handle material as described under the section heading "Disposal considerations".
Materials: absorbent material (e.g., sand, kieselguhr, universal binder)
Related Substances
Similar chemicals with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Risks inherent to handling the product must be minimised by applying the appropriate protective and preventive measures. Working processes should - so far as possible, according to the state of the art - be designed to rule out bodily contact or the release of hazardous substances.
Keep container tightly closed in a cool, well-ventilated place.
Do not eat, drink or smoke during work time. Keep away from food, drink and animal feeding stuffs. Wash hands and skin before breaks and after work. Do not inhale vapours. Avoid contact with eyes and skin. Remove soiled or soaked clothing immediately. Have emergency shower available.
Keep away from sources of heat and ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Sufficient protection is given wearing suitable protective gloves checked according to i.e. EN 374, in the event of risk of skin contact with the product. Before use, the protective gloves should be tested in any case for its specific work-station suitability (i.e. mechanical resistance, product compatibility and antistatic properties). Adhere to the manufacturer’s instructions and information relating to the use, storage, care and replacement of protective gloves. Protective gloves shall be replaced immediately when physically damaged or worn. Design operations thus to avoid permanent use of protective gloves.
Safety glasses with side protection shield (EN 166)
If workplace exposure limits are exceeded, a respiration protection approved for this particular job must be worn. In case of aerosol and mist formation, take appropriate measures for breathing protection in the event workplace threshold values are not specified.
Normal chemical work clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage and handling conditions (See section 7).
Dangerous reactions are not expected if the product is handled according to its intended use.
None, when used as directed.
None, if handled according to intended use.
Oxidizing agents
None, if handled according to intended use.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Allocation of a waste code number, according to the European Waste Catalogue, should be carried out in agreement with the regional waste disposal company.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for CELLPACK DST?
The signal word is warning.
What is the physical form of CELLPACK DST?
CELLPACK DST is a liquid with light yellow color. It has odourless odor.
What is the solubility of CELLPACK DST?
No data available
What is CELLPACK DST used for?
For in-vitro diagnosis
What are the hazard statements for CELLPACK DST?
This substance has 1 hazard statement:
- H317: May cause an allergic skin reaction.
What is the melting point of CELLPACK DST?
The melting point is No data available and the boiling point is appr. 100°C.