01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
DACPLUS

Regulatory Identifiers

CAS Number
N/A

Identified Uses

water based acrylic paint , outdoor application

Manufacturers & Suppliers

K

KORAMIC

manufacturer

Moeskroensesteenweg 296 – 8511 Aalbeke, BELGIUM

00 32 (0) 56/ 439 320

Emergency Contacts

Emergency Contact

0 0032/ (0) 56/ 439 320

official advisory body

0 0032/(0) 70/ 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This preparation does not contain any substances presenting a health or environmental hazard within the meaning of the Dangerous Substances Directive 67/548/EEC.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air, keep patient warm and at rest, if breathing is irregular or stopped, administer artificial respiration. Give nothing by mouth. If unconscious place in recovery position and seek medical advice.

Skin contact

Remove contaminated clothing. Wash skin thoroughly with soap and water or use recognised skin cleanser. Do NOT use solvents or thinners.

Eye contact

Remove contact lenses, irrigate copiously with clean, fresh water for at least 10 minutes, holding the eyelids apart and seek medical advice.

Ingestion

If accidentally swallowed obtain immediate medical attention. Keep at rest. Do NOT induce vomiting.

Immediate Medical Attention

If accidentally swallowed obtain immediate medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

alcohol resistant foam, CO₂, powders, water spray

Unsuitable media

waterjet

Specific hazards

Fire will produce dense black smoke. Exposure to decomposition products may cause a health hazard.

Instructions

Cool closed containers exposed to fire with water.

Firefighter Protection

Appropriate breathing apparatus may be required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid breathing vapours.

Environmental

If the product contaminates lakes, rivers or sewers, inform appropriate authorities in accordance with local regulations.

Cleanup methods

Clean preferably with a detergent; avoid use of solvents.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep container tightly closed. Avoid skin and eye contact. Avoid inhalation of vapour and spray mist. Smoking, eating and drinking should be prohibited in application area. Never use pressure to empty : container is not a pressure vessel. Always keep in containers of same material as the original one. Comply with the health and safety at work laws.

Storage

Store in accordance with local regulations. Store between 5 and 25°C in a dry, well ventilated place. Prevent unauthorized access. Containers which are opened must be carefully resealed and kept upright to prevent leakage.

Hygiene

Smoking, eating and drinking should be prohibited in application area.

Fire prevention

No smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide adequate ventilation. Where reasonably practicable this should be achieved by the use of local exhaust ventilation and good general extraction.

Hands

For prolonged or repeated contact, use neoprene gloves . Barrier creams may help to protect the exposed areas of the skin, they should however not be applied once exposure has occurred.

Eyes

Use safety eyewear designed to protect against splash of liquids.

Respiratory

not applicable

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
---
Colour Intensity
---
Form
---
Odor
---
Odor Threshold
---
Ph
---
Melting Point
---
Boiling Point
---
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
not applicable
Relative Density
1.18 kg/l
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
not applicable
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
miscible in water
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
0.8 P Method : ICI10000/s
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage and handling conditions.

Reactivity

Exothermic reactions may occur with oxidising agents, strongly alkaline and strongly acid materials.

Avoid

high temperatures

Incompatible

oxidising agents, strongly alkaline and strongly acid materials

Decomposition

carbon monoxide and dioxide, smoke, oxides of nitrogen

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for DACPLUS?

The signal word is no signal word.

What is the physical form of DACPLUS?

DACPLUS is a liquid .

What is DACPLUS used for?

water based acrylic paint , outdoor application