NextSDS Logo
Safety Data Sheet EN

Catalyst Platinum

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Catalyst Platinum
Product Code
2CA10316

Regulatory Identifiers

CAS Number
N/A
REACH No.
A registration number is not available for this substance as the substance or its uses are exempted from registration, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.

Identified Uses

Reagent for analysis

Manufacturers & Suppliers

S

Skalar Analytical B.V.

manufacturer

Tinstraat 12, 4823 AA Breda, The Netherlands

0031 765 486 486

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Aluminum oxide EC: 215-691-6 1344-28-1 99% No
Platinum EC: 231-116-1 7440-06-4 1% No

Notes

For full text of the H-Statements mentioned in this Section, see Section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

Skin contact

Wash off with plenty of water.

Eye contact

Flush eyes with water for 15 minutes. Consult a physician.

Ingestion

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Specific hazards

The catalyst may cause fire in contact with combustible gases or vapors of combustible liquids.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid dust formation. Avoid breathing vapors, mist or gas.

Environmental

Do not let product enter drains.

Cleanup methods

Pick up mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Store in cool place. Keep container tightly closed in a dry and well-ventilated place.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

Hands

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves must satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.

Eyes

Tightly fitting safety goggles. Face shield (8-inch minimum. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166 (EU).

Respiratory

Respiratory protection is not required. Where protection from nuisance levels of dusts are desired, use type N95 (US) or type P1 (EN 143) dust masks. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Skin/Body

Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific work-place. The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

Environmental

Prevent further leakage or spillage if safe to do so. Do not let product enter drains. Discharge into the environment must be avoided.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
Form: Solid, Color: Grey/black
Colour
Grey/black
Colour Intensity
---
Form
Solid
Odor
Odorless
Odor Threshold
No data available
Ph
No data available
Melting Point
No data available
Boiling Point
No data available
Flash Point
No data available
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
ca 500-1000 kg/m³
Density
---
Flammability
No data available
Upper Explosive Limit
Not explosive
Lower Explosive Limit
Not explosive
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
No data available
Solubility In Water
Insoluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions

Reactivity

No data available

Hazardous reactions

No data available

Avoid

Used catalysts contaminated with combustible materials may be spontaneously inflammable. Keep these catalysts always wet with water. Store away from flammable substances. Do not store with materials which release oxygen.

Incompatible

No data available

Decomposition

Other decomposition products - no data available. In the event of fire: see Section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Offer surplus and non-recyclable solutions to a licensed disposal company.

Disposal

Offer surplus and non-recyclable solutions to a licensed disposal company.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
Not dangerous goods
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This safety data sheet complies with the requirements of Regulation (EC) No. 1272/2008

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Catalyst Platinum?

The signal word is no signal word.

What is the physical form of Catalyst Platinum?

Catalyst Platinum is a solid appearing as form: solid, color: grey/black with grey/black color. It has odorless odor.

What is Catalyst Platinum used for?

Reagent for analysis

What is the melting point of Catalyst Platinum?

The melting point is No data available and the boiling point is No data available.