NextSDS Logo
Safety Data Sheet EN

PLATINUM CATALYST

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PLATINUM CATALYST

Regulatory Identifiers

CAS Number
N/A

Identified Uses

General chemical processes

Uses advised against

No data available.

Manufacturers & Suppliers

S

Shimadzu Europa GmbH

distributor

Albert-Hahn-Str. 6-10, 47269 Duisburg

+49 (0)203 - 7687-0

Emergency Contacts

Giftinformationszentrum Nord

+49 (0)551 192 40

DE, EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
aluminium oxide EC: 215-691-6 1344-28-1 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove affected person from the immediate area. Ensure supply of fresh air.

Skin contact

Wash off immediately with soap and water.

Eye contact

Separate eyelids, wash the eyes thoroughly with water (15 min.).

Ingestion

Seek medical advice immediately. Rinse the mouth thoroughly with water. Never give anything by mouth to an unconscious person.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam; Carbon dioxide; Extinguishing powder; Water spray jet

Unsuitable media

No data available.

Specific hazards

In the event of fire, the following can be released: Carbon dioxide (CO2); Carbon monoxide (CO); Combustion products of this material have to be classed invariably as respiratory poison.

Instructions

Fire-fighting operations, rescue and clearing work under effect of combustion and smoulder gases just may be done with breathing apparatus.

Firefighter Protection

Wear protective clothing.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Ensure adequate ventilation. Avoid dust formation. Keep away from ignition sources.

Environmental

Do not discharge into the drains/surface waters/groundwater.

Cleanup methods

Collect mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures necessary if stored and handled as prescribed. Avoid the formation and deposition of dust. Provide good ventilation at the work area (local exhaust ventilation, if necessary).

Storage

Keep container tightly closed and dry in a cool, well-ventilated place.

Hygiene

Do not eat, drink or smoke during work time. Keep away from foodstuffs and beverages. Wash hands before breaks and after work. Provide eye wash fountain in work area. Do not inhale dust.

Fire prevention

Keep away from sources of heat and ignition. Take precautionary measures against static charges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No data available.

Hands

In case of intensive contact, wear protective gloves (EN 374). Sufficient protection is given wearing suitable protective gloves checked according to i.e. EN 374, in the event of risk of skin contact with the product. Before use, the protective gloves should be tested in any case for its specific work-station suitability (i.e. mechanical resistance, product compatibility and antistatic properties). Adhere to the manufacturer's instructions and information relating to the use, storage, care and replacement of protective gloves. Protective gloves shall be replaced immediately when physically damaged or worn. Design operations thus to avoid permanent use of protective gloves. Appropriate Material: nitrile, Material thickness: > 0.3 mm, Breakthrough time: > 480 min. Appropriate Material: rubber, Material thickness: > 0.5 mm, Breakthrough time: > 240 min.

Eyes

Safety glasses (EN 166)

Respiratory

If workplace exposure limits are exceeded, a respiration protection approved for this particular job must be worn.

Skin/Body

Normal chemical work clothing.

Environmental

No data available.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Lower Explosive Limit
---
Melting Point
---
Solubility In Fat
---
Evaporation Rate
---
Explosive Limits
---
Freezing Point
---
Molecular Weight
---
Flash Point
---
Bulk Density
610 - 690 kg/m³
Auto Ignition Temperature
---
Relative Evaporation Rate
---
Solidification Point
---
Appearance
---
Kinematic Viscosity
---
State Under Standard Conditions
---
Softening Point
---
Relative Density
---
Ph
---
Solubility In Water
insoluble
Flammability
---
Colour
black; grey
Odor Threshold
---
Metal Corrosion
---
Partition Coefficient
---
Solubility
---
Odor
odourless
Properties Status
---
Colour Intensity
---
Decomposition Temperature
---
Physical State Data
solid
Upper Explosive Limit
---
Boiling Point
---
Vapor Pressure
---
Crystallisation Point
---
Physical State
solid
Voc Content
---
Cloud Point
---
Dynamic Viscosity
---
Vapor Density
---
Density
---
Form
Powder
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable if stored and handled properly.

Reactivity

No data available.

Hazardous reactions

No data available.

Avoid

No data available.

Incompatible

Oxidizing agents; Acids; Alkalis; Reducing agents

Decomposition

No data available.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PLATINUM CATALYST?

The signal word is no signal word.

What is the physical form of PLATINUM CATALYST?

PLATINUM CATALYST is a solid with black; grey color. It has odourless odor.

What is PLATINUM CATALYST used for?

General chemical processes