Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Brij35, 30% solution
- Product Code
- 13900
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
Skalar Analytical B.V.
Tinstraat 12 4823 AA Breda The Netherlands
0031 765 486 486
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Ethoxylated lauryl alcohol | 9002-92-0 | 2 - 4% | No |
Notes
No components need to be disclosed according to the applicable regulations.
First Aid Measures
Emergency procedures for chemical exposure incidents
If breathed in, move person into fresh air. If not breathing, give artificial respiration.
Wash off with soap and plenty of water for at least 15 minutes.
Remove contact lenses if present and easy to do so. Rinse immediately but cautiously with plenty of water, also under the eyelids, for at least 15 minutes.
Never give anything by mouth to an unconscious person. Do not induce vomiting. Rinse mouth with water.
Immediate Medical Attention
Immediate medical attention is required. If skin irritation occurs: Get medical advice/ attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
No data available.
Firefighter Protection
Wear self-contained breathing apparatus and protective suit for firefighting.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid dust formation, breathing vapors, mist or gas. Avoid contact with skin, eyes or clothing.
No special environmental precautions required.
Soak up with inert absorbent material. Keep in suitable, closed containers for disposal.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Brij35, 30% solution
---
Glyoxal, 40% aqueous solution
CAS: 107-22-2
3-HYDROXYPROPIONIC ACID 30% SOLUTION IN WATER
---
Hydrogen peroxide, 30%
---
Sodium Methylate solution 30 %
---
Sulfuric Acid 50% (w/w) Solution
CAS: Mixture.
Methylamine, 40% w/w aqueous solution
---
FORMALDEHYDE 40% SOLUTION
CAS: 50-00-0
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Always wear recommended personal protective equipment. Provide appropriate exhaust ventilation or wear appropriate respiratory equipment. For precautions see section 2.2.
Keep container tightly closed in a dry and well-ventilated place. Store in cool place.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
General industrial hygiene practice.
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove’s outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands. The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it. Full contact Material: Nitrile rubber Minimum layer thickness: 0.11 mm Break through time: 480 min Splash contact Material: Nitrile rubber Minimum layer thickness: 0,11 mm Break through time: 480 min If used in solution, or mixed with other substances, and under conditions which differ from EN 374, contact the supplier of the CE approved gloves. This recommendation is advisory only and must be evaluated by an industrial hygienist and safety officer familiar with the specific situation of anticipated use by our customers. It should not be construed as offering an approval for any specific use scenario.
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Respiratory protection not required. For nuisance exposures use type OV/AG (US) or type ABEK (EU EN 14387) respirator cartridges. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Complete suit protecting against chemicals, the type of protective equipment must be selected according to the concentration and amount of the substance at the specific workplace.
No special environmental precautions required.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions
No data available
No data available
No data available
Strong oxidizing agents
Other decomposition products- no data available
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- Shipping Name
- Not dangerous goods
No data available
No data available
No data available
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Brij35, 30% solution?
The signal word is no signal word.
What is the physical form of Brij35, 30% solution?
Brij35, 30% solution is a liquid appearing as liquid, clear with colorless color. It has no data available odor.
What is Brij35, 30% solution used for?
Reagent for analysis
What is the melting point of Brij35, 30% solution?
The melting point is No data available and the boiling point is No data available.