NextSDS Logo
Hy

Hyspin AWH-M 32 Superclean

NO SIGNAL WORD Liquid. SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Hyspin AWH-M 32 Superclean
Product Form
Liquid.
Product Code
466948-FR01

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Hydraulic fluid. For specific application advice see appropriate Technical Data Sheet or consult our company representative.

Overview

Hyspin AWH-M 32 Superclean commonly used hydraulic fluid. for specific application advice see appropriate technical data sheet or consult our company representative..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (No signal word.)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • No known significant effects or critical hazards.

Precautionary Statements

  • Not applicable.
  • Not applicable.
  • Not applicable.
  • Not applicable.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Castrol Industrial - divisie BP Europa SE - BP Belgium

undefined

Amocolaan 2 2440 Geel BELGIUM

BE

+32 (0)800 40752

+32 (0)800 40750

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Carechem

+44 (0) 1235 239 670

GB

24/7

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Highly refined base oil (IP 346 DMSO extract < 3%). Proprietary performance additives.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
N/A N/A 50-75% Hazardous
N/A N/A 25-50% Non-hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

If inhaled, remove to fresh air. Get medical attention if symptoms occur.

Symptoms:

Overexposure to the inhalation of airborne droplets or aerosols may cause irritation of the respiratory tract.

Skin Contact

Wash skin thoroughly with soap and water or use recognised skin cleanser. Remove contaminated clothing and shoes. Wash clothing before reuse. Clean shoes thoroughly before reuse. Get medical attention if irritation develops.

Symptoms:

Prolonged or repeated contact can defat the skin and lead to irritation and/or dermatitis.

Eye Contact

In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Eyelids should be held away from the eyeball to ensure thorough rinsing. Check for and remove any contact lenses. Get medical attention.

Symptoms:

Potential risk of transient stinging or redness if accidental eye contact occurs.

Ingestion/Swallowing

Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

Symptoms:

Ingestion of large quantities may cause nausea and diarrhoea.

Immediate Medical Attention Required

Injections through the skin resulting from contact with the product at high pressure constitute a major medical emergency. Surgical exploration should be undertaken without delay.

Medical Treatment

Treatment should in general be symptomatic and directed to relieving any effects. Note: High Pressure Applications Injections through the skin resulting from contact with the product at high pressure constitute a major medical emergency. Injuries may not appear serious at first but within a few hours tissue becomes swollen, discoloured and extremely painful with extensive subcutaneous necrosis. Surgical exploration should be undertaken without delay. Thorough and extensive debridement of the wound and underlying tissue is necessary to minimise tissue loss and prevent or limit permanent damage. Note that high pressure may force the product considerable distances along tissue planes.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

In case of fire, use foam, dry chemical or carbon dioxide extinguisher or spray.

Unsuitable Extinguishing Media

Do not use water jet. The use of a water jet may cause the fire to spread by splashing the burning product.

Specific Fire Hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Fire Fighting Instructions

No action shall be taken involving any personal risk or without suitable training. Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire.

Firefighter Protection Equipment

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Floors may be slippery; use care to avoid falling. Put on appropriate personal protective equipment.

Small Spill Procedures

Stop leak if without risk. Move containers from spill area. Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large Spill Procedures

Stop leak if without risk. Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations. Dispose of via a licensed waste disposal contractor.

Environmental Precautions

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).

Cleanup Methods

Absorb with an inert material and place in an appropriate waste disposal container. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations.

Cleanup Materials:

inert material; non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Liquid.
Critical Property
Physical State Data
liquid
State Under Standard Conditions
Not available
Appearance
Not available
Colour
Yellow. [Light]
Colour Intensity
Light
Form
Not available
Odor
Not available.
Odor Threshold
Not available.
Ph
Not available.
Melting Point
Not available.
Critical Property
Boiling Point
Not available.
Critical Property
Flash Point
Closed cup: >190°C (>374°F) [Pensky-Martens.]
Critical Property
Freezing Point
Not available.
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Not available.
Vapor Pressure
Not available.
Vapor Density
Not available.
Relative Density
Not available.
Bulk Density
Not available
Density
<1000 kg/m³ (<1 g/cm³) at 15°C
Critical Property
Flammability
Not available.
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
Not available
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
insoluble in water.
Partition Coefficient
Not available.
Solubility In Water
insoluble in water.
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
Not available
Kinematic Viscosity
Kinematic: 32 mm2/s (32 cSt) at 40°C; Kinematic: 6.3 mm2/s (6.3 cSt) at 100°C
Properties Status
Not available
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Put on appropriate personal protective equipment.

Storage Conditions

Store in accordance with local regulations.

Store in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10).

Keep away from heat and direct sunlight.

Keep container tightly closed and sealed until ready for use.

Containers that have been opened must be carefully resealed and kept upright to prevent leakage.

Store and use only in equipment/containers designed for use with this product.

Do not store in unlabelled containers.

General Hygiene Measures

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Wash thoroughly after handling. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Provide exhaust ventilation or other engineering controls to keep the relevant airborne concentrations below their respective occupational exposure limits. All activities involving chemicals should be assessed for their risks to health, to ensure exposures are adequately controlled. Personal protective equipment should only be considered after other forms of control measures (e.g. engineering controls) have been suitably evaluated. Personal protective equipment should conform to appropriate standards, be suitable for use, be kept in good condition and properly maintained. Your supplier of personal protective equipment should be consulted for advice on selection and appropriate standards. For further information contact your national organisation for standards. The final choice of protective equipment will depend upon a risk assessment. It is important to ensure that all items of personal protective equipment are compatible.

Hand Protection

In case of insufficient ventilation, wear suitable respiratory equipment. The correct choice of respiratory protection depends upon the chemicals being handled, the conditions of work and use, and the condition of the respiratory equipment. Safety procedures should be developed for each intended application. Respiratory protection equipment should therefore be chosen in consultation with the supplier/manufacturer and with a full assessment of the working conditions. General Information: Because specific work environments and material handling practices vary, safety procedures should be developed for each intended application. The correct choice of protective gloves depends upon the chemicals being handled, and the conditions of work and use. Most gloves provide protection for only a limited time before they must be discarded and replaced (even the best chemically resistant gloves will break down after repeated chemical exposures). Gloves should be chosen in consultation with the supplier / manufacturer and taking account of a full assessment of the working conditions. Recommended: Nitrile gloves. Breakthrough time: Breakthrough time data are generated by glove manufacturers under laboratory test conditions and represent how long a glove can be expected to provide effective permeation resistance. It is important when following breakthrough time recommendations that actual workplace conditions are taken into account. Always consult with your glove supplier for up-to-date technical information on breakthrough times for the recommended glove type. Our recommendations on the selection of gloves are as follows: Continuous contact: Gloves with a minimum breakthrough time of 240 minutes, or >480 minutes if suitable gloves can be obtained. If suitable gloves are not available to offer that level of protection, gloves with shorter breakthrough times may be acceptable as long as appropriate glove maintenance and replacement regimes are determined and adhered to. Short-term / splash protection: Recommended breakthrough times as above. It is recognised that for short-term, transient exposures, gloves with shorter breakthrough times may commonly be used. Therefore, appropriate maintenance and replacement regimes must be determined and rigorously followed. Glove Thickness: For general applications, we recommend gloves with a thickness typically greater than 0.35 mm. It should be emphasised that glove thickness is not necessarily a good predictor of glove resistance to a specific chemical, as the permeation efficiency of the glove will be dependent on the exact composition of the glove material. Therefore, glove selection should also be based on consideration of the task requirements and knowledge of breakthrough times. Glove thickness may also vary depending on the glove manufacturer, the glove type and the glove model. Therefore, the manufacturers’ technical data should always be taken into account to ensure selection of the most appropriate glove for the task. Note: Depending on the activity being conducted, gloves of varying thickness may be required for specific tasks. For example: • Thinner gloves (down to 0.1 mm or less) may be required where a high degree of manual dexterity is needed. However, these gloves are only likely to give short duration protection and would normally be just for single use applications, then disposed of. • Thicker gloves (up to 3 mm or more) may be required where there is a mechanical (as well as a chemical) risk i.e. where there is abrasion or puncture potential. Refer to standards: Gloves: EN 420, EN 374

Eye Protection

Safety glasses with side shields. Refer to standards: Eye protection: EN 166

Respiratory Protection

In case of insufficient ventilation, wear suitable respiratory equipment. The correct choice of respiratory protection depends upon the chemicals being handled, the conditions of work and use, and the condition of the respiratory equipment. Safety procedures should be developed for each intended application. Respiratory protection equipment should therefore be chosen in consultation with the supplier/manufacturer and with a full assessment of the working conditions. Refer to standards: Respiratory protection: EN 529 Filtering half-mask: EN 149 Filtering half-mask with valve: EN 405 Half-mask: EN 140 plus filter Full-face mask: EN 136 plus filter Particulate filters: EN 143 Gas/combined filters: EN 14387

Skin/Body Protection

Use of protective clothing is good industrial practice. Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Cotton or polyester/cotton overalls will only provide protection against light superficial contamination that will not soak through to the skin. Overalls should be laundered on a regular basis. When the risk of skin exposure is high (e.g. when cleaning up spillages or if there is a risk of splashing) then chemical resistant aprons and/or impervious chemical suits and boots will be required.

Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

The product is stable.

Reactivity

No specific test data available for this product. Refer to Conditions to avoid and Incompatible materials for additional information.

Hazardous Reactions

Under normal conditions of storage and use, hazardous reactions will not occur. Under normal conditions of storage and use, hazardous polymerisation will not occur.

Conditions to Avoid

Avoid all possible sources of ignition (spark or flame).

Incompatible Materials

Reactive or incompatible with the following materials: oxidising materials.

Hazardous Decomposition Products

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Hyspin AWH-M 32 Superclean?

The signal word for this substance is "no signal word".

What is the physical form of Hyspin AWH-M 32 Superclean?

Hyspin AWH-M 32 Superclean is a liquid. with yellow. [light] color. It has not available. odor.

What is the solubility of Hyspin AWH-M 32 Superclean?

insoluble in water.

What is Hyspin AWH-M 32 Superclean used for?

Hydraulic fluid. For specific application advice see appropriate Technical Data Sheet or consult our company representative.

What are the hazard statements for Hyspin AWH-M 32 Superclean?

This substance has 1 hazard statements: No known significant effects or critical hazards.

What is the melting point of Hyspin AWH-M 32 Superclean?

The melting point is Not available. and the boiling point is Not available..