NextSDS Logo
Safety Data Sheet EN

FLAMMADUR® A 77 HF

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
FLAMMADUR® A 77 HF

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Coating material

Manufacturers & Suppliers

AIK Flammadur Brandschutz GmbH logo

AIK Flammadur Brandschutz GmbH

manufacturer

Otto-Hahn-Str. 5, D-34123 Kassel

++49-(0)561-5801-0

http://aik-flammadur.de

Emergency Contacts

GBK GmbH

+49 - (0) 6132 - 84463

24h - 7d/w - 365d/a

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture containing following substances with additives

Chemical Name CAS Number Concentration Hazardous
triethyl phosphate EC: 201-114-5 78-40-0 5 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Take affected person into fresh air. Consult a physician.

Skin contact

In case of contact with skin wash off immediately with plenty of water.

Eye contact

Do not rub eyes. Rinse thoroughly with plenty of water, also under the eyelids. If eye irritation persists, consult a specialist.

Symptoms: contains inorganic fillers, which irritate the eyes mechanically like other inert materials.

Ingestion

Never give anything by mouth to an unconscious person. Do not induce vomiting. Rinse out mouth and give plenty of water to drink. Consult a physician.

Medical Treatment

Treat symptoms.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, carbon dioxide (CO2), dry chemical, water-spray

Specific hazards

carbon monoxide and carbon dioxide

Firefighter Protection

In case of fire, wear suitable respiratory equipment with positive air supply.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with eyes, skin or mucous membrane.

Environmental

Do not discharge large amounts into the drains or bodies of water.

Cleanup methods

Soak up with inert absorbent material

Materials: sand, silica gel, acid binder, universal binder

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Take the usual precautions when handling with chemicals.

Storage

Keep container tightly closed in a dry, cool and well-ventilated place. Keep from freezing. Protect from heat and direct solar radiation.

Hygiene

Take the usual precautions when handling with chemicals.

Fire prevention

No special precautions required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide appropriate exhaust ventilation at machinery and at places where dust can be generated.

Hands

Chemical-resistant gloves (EN 374) Safety gloves for the site (EN420, Cat. 1 or 2). Follow the recommendations of the glove manufacturer for breakthrough properties especially for workplace conditions involving mechanical stress and contact duration.

Eyes

During transferring safety goggles are recommended. Tightly fitting goggles (EN 166).

Respiratory

Not required under normal use.

Skin/Body

Protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor Threshold
---
Voc Content
---
Auto Ignition Temperature
390 °C
Solidification Point
---
Colour
according to product specification
Bulk Density
---
Solubility In Water
Completely miscible
Odor
Characteristic
Vapor Density
---
Freezing Point
---
Lower Explosive Limit
Not applicable
Upper Explosive Limit
Not applicable
Colour Intensity
---
Physical State
Pasty
Decomposition Temperature
---
Kinematic Viscosity
Not applicable
Cloud Point
---
Solubility
---
Explosive Limits
---
Metal Corrosion
---
Flash Point
240 °C
Boiling Point
100 °C
Appearance
---
Crystallisation Point
---
Density
1,25 g/cm³
Evaporation Rate
---
Melting Point
Not determined
State Under Standard Conditions
---
Form
---
Ph
Not determined
Relative Evaporation Rate
---
Molecular Weight
---
Solubility In Fat
---
Properties Status
---
Vapor Pressure
23 hPa
Physical State Data
liquid
Flammability
---
Partition Coefficient
Not applicable
Dynamic Viscosity
65000 mPa·s
Softening Point
Not determined
Relative Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No data available

Hazardous reactions

None under normal processing.

Avoid

To avoid thermal decomposition, do not overheat. Keep from freezing.

Incompatible

Strong oxidizing agents. Strong acids. Strong bases.

Decomposition

No decomposition if stored and applied as directed.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Do not discharge into the drains/surface waters/ground water. The waste code number must be agreed with the disposer / manufacturer / competent authority.

Disposal

Waste disposal according to local regulations.

Waste Codes

200128 MUNICIPAL WASTES (HOUSEHOLD WASTE AND SIMILAR COMMERCIAL, INDUSTRIAL AND INSTITUTIONAL WASTES) INCLUDING SEPARATELY COLLECTED FRACTIONS; separately collected fractions (except 15 01); paint, inks, adhesives and resins other than those mentioned in 20 01 27 EWC
150104 WASTE PACKAGING; ABSORBENTS, WIPING CLOTHS, FILTER MATERIALS AND PROTECTIVE CLOTHING NOT OTHERWISE SPECIFIED; packaging (including separately collected municipal packaging waste); metallic packaging EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for FLAMMADUR® A 77 HF?

The signal word is no signal word.

What is the physical form of FLAMMADUR® A 77 HF?

FLAMMADUR® A 77 HF is a pasty with according to product specification color. It has characteristic odor.

What is FLAMMADUR® A 77 HF used for?

Coating material

What is the melting point of FLAMMADUR® A 77 HF?

The melting point is Not determined and the boiling point is 100 °C.