Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
AFLAMMIT PLF 280

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Flame retarding agent for industrial and/or commercial use.

Manufacturers & Suppliers

T

Thor Specialities (UK) LTD.

national supplier

Wincham Avenue, Wincham, Cheshire CW9 6GB, United Kingdom

+44 (0) 1606 818800

Emergency Contacts

National Poisons Information Service

+44 (0) 844-892-0111

24 h service

Emergency Contact

+49 621 60-43333

24 h service

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Flame retardant based on an organic phosphorous compound.

Chemical Name CAS Number Concentration Hazardous
triphenyl phosphate EC: 204-112-2 115-86-6 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of symptoms.

Skin contact

IF ON SKIN: Wash with plenty of soap and water.

Eye contact

Rinse eyes thoroughly with plenty of water for at least 10 minutes while holding eyelids open. If symptoms persist, consult a physician.

Ingestion

Rinse mouth and drink plenty of water. Seek medical treatment.

Immediate Medical Attention

Seek medical treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray jet, extinguishing powder, CO2, foam.

Specific hazards

In case of fire, toxic incineration products may be released such as: Carbon monoxide (CO), Phosphoric oxides (PxOy)

Firefighter Protection

Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective clothing (see item 8).

Small spill

Cover the rest with absorbent, mix intensively and collect mechanically.

Large spill

Collect large amounts in suitable container.

Environmental

Do not allow product to enter waters without treatment in a (biological) water treatment plant.

Cleanup methods

Collect large amounts in suitable container. Cover the rest with absorbent, mix intensively and collect mechanically.

Materials: multi-purpose absorbent

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Risks to the safety and health of workers may not only be created by work involving chemicals but, inter alia by work equipment and the fitting-out of work-places. Those risks shall be identified and evaluated.

Storage

Keep containers tightly sealed.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Chemical protective gloves according to DIN EN 374 with CE-labelling. Do not wear protective gloves longer than necessary. After use of gloves apply skin-cleaning agents and skin cosmetics. Material of gloves: Nitrile rubber, NBR

Eyes

Safety glasses recommended during refilling.

Respiratory

Not required

Skin/Body

Protective clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Colourless to yellowish
Colour
Colourless to yellowish
Colour Intensity
---
Form
Liquid, Viscous
Odor
Odourless
Odor Threshold
Not relevant for safety
Ph
Not determined
Melting Point
- 12 °C
Boiling Point
> 400 °C
Flash Point
> 225 °C
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
< 1.3 hPa
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1.280-1.320 g/cm3
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
585 °C
Decomposition Temperature
> 300 °C
Solubility
---
Partition Coefficient
---
Solubility In Water
< 10 ppm
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
600 mPas
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

Up to now, no dangers resulting from a reactivity of the mixture have been identified.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

Acids

Decomposition

None, if storage and handling is done according to specification.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for AFLAMMIT PLF 280?

The signal word is no signal word.

What is the physical form of AFLAMMIT PLF 280?

AFLAMMIT PLF 280 is a liquid appearing as colourless to yellowish with colourless to yellowish color. It has odourless odor.

What is AFLAMMIT PLF 280 used for?

Flame retarding agent for industrial and/or commercial use.

What is the melting point of AFLAMMIT PLF 280?

The melting point is - 12 °C and the boiling point is > 400 °C.