NextSDS Logo
Safety Data Sheet EN

PARAFORMALDEHYDE 16% SOLUTION, EM GRADE

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
PARAFORMALDEHYDE 16% SOLUTION, EM GRADE
Product Code
15710-250

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals

Manufacturers & Suppliers

Electron Microscopy Sciences logo

Electron Microscopy Sciences

manufacturer

1560 Industry Road USA-Hatfield, PA 19440

215-412-8400

www.emsdiasum.com

ProSciTech Pty Ltd logo

ProSciTech Pty Ltd

11 Carlton Street, Kirwan QLD 4817 Australia

ems.proscitech.com

Emgrid Australia Pty. Ltd. logo

Emgrid Australia Pty. Ltd.

P.O. Box 118 The Patch VIC 3792 Australia

03 9752 1785

www.emgrid.com.au

Emergency Contacts

ChemTrec

1-800-424-9300

Emergency Contact

1-703-527-3887

ProSciTech Pty Ltd

(07) 4773 9444

8:30am - 5:00pm, Monday to Friday (excluding Public Holidays)

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Resp. Sens. Cat. 1 H334
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2A H319
Flam. Liq. Cat. 4 H227

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled.

Precautionary Statements

Keep away from heat/sparks/open flames/hot surfaces. No smoking. Avoid breathing dust/fume/gas/mist/vapours/spray.
Wear protective gloves/protective clothing/eye protection/face protection.
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Dispose of contents/container in accordance with local/regional/national/international regulations.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
Paraformaldehyde 30525-89-4 10 - 25% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of unconsciousness place patient stably in side position for transportation.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

Call for a doctor immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO _{2} , powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Dilute with plenty of water. Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material. Dispose contaminated material as waste according to section 13.

Materials: liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols.

Storage

Keep container tightly sealed.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Protective gloves The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation Material of gloves The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed goggles

Respiratory

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Fluid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colourless
Colour Intensity
---
Form
Liquid
Odor
Like aldehyde
Odor Threshold
Not determined.
Ph
2.8
Melting Point
Undetermined.
Boiling Point
>93 °C
Flash Point
62 °C
Freezing Point
Undetermined.
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
23 hPa
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
1.04 g/cm³
Flammability
Not applicable.
Upper Explosive Limit
73 Vol %
Lower Explosive Limit
7 Vol %
Explosive Limits
---
Auto Ignition Temperature
~300 °C
Decomposition Temperature
Not determined.
Solubility
Fully miscible.
Partition Coefficient
Not determined.
Solubility In Water
Fully miscible.
Solubility In Fat
---
Molecular Weight
---
Voc Content
0.00 %
Metal Corrosion
---
Dynamic Viscosity
Not determined.
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN3334
Shipping Name
Aviation regulated liquid, n.o.s.
Transport Class
9 Miscellaneous dangerous substances and articles.
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for PARAFORMALDEHYDE 16% SOLUTION, EM GRADE?

The signal word is danger.

What is the physical form of PARAFORMALDEHYDE 16% SOLUTION, EM GRADE?

PARAFORMALDEHYDE 16% SOLUTION, EM GRADE is a fluid with colourless color. It has like aldehyde odor.

What is the solubility of PARAFORMALDEHYDE 16% SOLUTION, EM GRADE?

Fully miscible.

What is PARAFORMALDEHYDE 16% SOLUTION, EM GRADE used for?

Laboratory chemicals

What are the hazard statements for PARAFORMALDEHYDE 16% SOLUTION, EM GRADE?

This substance has 1 hazard statement:

  • H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.

What is the melting point of PARAFORMALDEHYDE 16% SOLUTION, EM GRADE?

The melting point is Undetermined. and the boiling point is >93 °C.

Compliance Scanner