NextSDS Logo
Safety Data Sheet EN

ETRO 4+

CAS 64742-54-7

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ETRO 4+
Synonyms
Base Oil

Regulatory Identifiers

CAS Number
64742-54-7 Check regulations →
REACH No.
01-2119484627-25-XXXX

Identified Uses

Lubricant base oil

Manufacturers & Suppliers

M

Malaysian Refining Company Sdn. Bhd.

manufacturer

Persiaran Penapisan, 76300 Sungai Udang, Melaka, Malaysia

Emergency Contacts

Fire Station Radio Operator

(+606)-352 2444

National Poison Centre

+604-6570099

Mon-Fri : 8.10 am - 5.10 pm

National Poison Centre

+6012-4309499

Mon-Fri : 5.10 pm - 10.10 pm) & (Sat, Sun & Public holiday : 8.10 am - 5.10 pm

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Asp. Tox. Cat. 1

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H304 May be fatal if swallowed and enters airways.

Precautionary Statements

P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER or doctor/ physician.
P331 Do NOT induce vomiting.
P405 Store locked up.
P501 Dispose of contents/ container to an approved waste disposal plant.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type uvcb
Chemical Name CAS Number Concentration Hazardous
Paraffinic Distillate, Heavy, Hydrotreated 64742-54-7 99 - 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a medical doctor.

Skin contact

If on clothes, remove clothes.

Eye contact

Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

Ingestion

Keep respiratory tract clear. Do NOT give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. Take victim immediately to hospital. If symptoms persist, call a medical doctor. Do NOT induce vomiting.

Immediate Medical Attention

Seek medical advice. Take victim immediately to hospital. If symptoms persist, call a medical doctor. If eye irritation persists, consult a specialist.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

High volume water jet

Instructions

Standard procedure for chemical fires. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective equipment. Ensure adequate ventilation.

Environmental

If the product contaminates rivers and lakes or drains inform respective authorities. Prevent further leakage or spillage if safe to do so. Prevent product from entering drains.

Cleanup methods

Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).

Materials: inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not breathe vapours/dust. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area.

Storage

Keep container tightly closed in a dry and well-ventilated place. Observe label precautions. Electrical installations / working materials must comply with the technological safety standards.

Hygiene

Smoking, eating and drinking should be prohibited in the application area.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Eyes

Tightly fitting safety goggles

Skin/Body

Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Clear and bright liquid
Colour
L 0.5 Method: ASTM D 1500
Colour Intensity
---
Form
---
Odor
No data available
Odor Threshold
No data available
Ph
No data available
Melting Point
Not applicable
Boiling Point
not determined
Flash Point
222 °C
Freezing Point
Not applicable
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Noack 13.0% mass
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
0.8307 g/cm3 (15 °C)
Flammability
Not applicable
Upper Explosive Limit
7 % (V)
Lower Explosive Limit
0.6 % (V)
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
No data available
Solubility In Water
Insoluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
18.15 mm2/s (40 °C) Method: ASTM D 445 : 4.13 mm2/s (100 °C) Method: ASTM D 445
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

Hazardous polymerisation does not occur.

Hazardous reactions

No dangerous reaction known under conditions of normal use.

Incompatible

Strong oxidizing agents

Decomposition

Fumes, smoke, carbon monoxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is ETRO 4+ known by?

ETRO 4+ is also known as: Base Oil

What is the hazard signal word for ETRO 4+?

The signal word is danger.

What is the physical form of ETRO 4+?

ETRO 4+ is a liquid appearing as clear and bright liquid with l 0.5 method: astm d 1500 color. It has no data available odor.

What is ETRO 4+ used for?

Lubricant base oil

What are the hazard statements for ETRO 4+?

This substance has 1 hazard statement:

  • H304: May be fatal if swallowed and enters airways.

What is the melting point of ETRO 4+?

The melting point is Not applicable and the boiling point is not determined.

Compliance Scanner

Scan your compliance