NextSDS Logo
Safety Data Sheet EN

ShellSol A150

EC 919-284-0

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
ShellSol A150
Product Code
Q7493
Synonyms
Hydrocarbons, C10, aromatics, >1% naphthalene

Regulatory Identifiers

CAS Number
N/A
EC Number
919-284-0 Check regulations →
REACH No.
01-2119463588-24-0002

Identified Uses

Industrial Solvent. Please refer to section 16 and/or the annexes for the registered uses under REACH.

Uses advised against

This product must not be used in applications other than the above without first seeking the advice of the supplier.

Manufacturers & Suppliers

S

Shell Chemicals Europe B.V.

manufacturer

PO Box 2334 3000 CH Rotterdam Netherlands

+31 (0)10 441 5137 / +31 (0)10 441 5191

Emergency Contacts

Emergency Contact

+44 (0) 1235 239 670

24 hours per day, 7 days per week

Numéro ORFILA (INRS)

+33 (0)1 45 42 59 59

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Asp. Tox. Cat. 1 H304
STOT SE Cat. 3 H336
Carc. Cat. 2 H351
Aquatic Chronic Cat. 2 H411

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

GHS09 - Environmental hazard

GHS09

Hazard Statements

H304 May be fatal if swallowed and enters airways.
H336 May cause drowsiness or dizziness.
H351 Suspected of causing cancer.
H411 Toxic to aquatic life with long lasting effects.

Precautionary Statements

P201 Obtain special instructions before use.
P261 Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor.
P308 + P313 IF exposed or concerned: Get medical advice/ attention.
P331 Do NOT induce vomiting.
P501 Dispose of contents/ container to an approved waste disposal plant.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
N/A --- 100% No
Naphthalene EC: 202-049-5 91-20-3 10% Yes
Cumene EC: 202-704-5 98-82-8 0.099% Yes
Benzene EC: 200-753-7 71-43-2 0.01% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. If rapid recovery does not occur, transport to nearest medical facility for additional treatment.

Symptoms: Breathing of high vapour concentrations may cause central nervous system (CNS) depression resulting in dizziness, light-headedness, headache, nausea and loss of coordination. Continued inhalation may result in unconsciousness and death. If material enters lungs, signs and symptoms may include coughing, choking, wheezing, difficulty in breathing, chest congestion, shortness of breath, and/or fever. Delayed symptoms within 6 hours may include fever greater than 101° F (38.3°C), shortness of breath, chest congestion or continued coughing or wheezing.

Skin contact

Remove contaminated clothing. Flush exposed area with water and follow by washing with soap if available. If persistent irritation occurs, obtain medical attention.

Symptoms: Skin irritation signs and symptoms may include a burning sensation, redness, or swelling. Defatting dermatitis signs and symptoms may include a burning sensation and/or a dried/cracked appearance.

Eye contact

Flush eye with copious quantities of water. Remove contact lenses, if present and easy to do. Continue rinsing. If persistent irritation occurs, obtain medical attention.

Symptoms: Eye irritation signs and symptoms may include a burning sensation, redness, swelling, and/or blurred vision.

Ingestion

Call emergency number for your location / facility. Do not induce vomiting: transport to nearest medical facility for additional treatment. If vomiting occurs spontaneously, keep head below hips to prevent aspiration.

Symptoms: If material enters lungs (aspiration), signs and symptoms may include coughing, choking, wheezing, difficulty in breathing, chest congestion, shortness of breath, and/or fever. If any of the following delayed signs and symptoms appear within the next 6 hours: fever greater than 101° F (38.3°C), shortness of breath, chest congestion or continued coughing or wheezing.

Immediate Medical Attention

If rapid recovery does not occur (inhalation), transport to nearest medical facility for additional treatment. If persistent irritation occurs (skin/eye), obtain medical attention. Call emergency number for your location / facility (ingestion). Transport to nearest medical facility for additional treatment (ingestion). If any of the following delayed signs and symptoms appear within the next 6 hours (after ingestion): fever greater than 101° F (38.3°C), shortness of breath, chest congestion or continued coughing or wheezing, transport to the nearest medical facility. Call a doctor or poison control center for guidance.

Medical Treatment

Call a doctor or poison control center for guidance. Potential for chemical pneumonitis. Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, water spray or fog. Dry chemical powder, carbon dioxide, sand or earth may be used for small fires only.

Unsuitable media

Do not use water in a jet.

Specific hazards

Clear fire area of all non-emergency personnel. Flammable vapours may be present even at temperatures below the flash point. The vapour is heavier than air, spreads along the ground and distant ignition is possible. Will float and can be reignited on surface water.

Instructions

Standard procedure for chemical fires. Keep adjacent containers cool by spraying with water.

Firefighter Protection

Proper protective equipment including chemical resistant gloves are to be worn; chemical resistant suit is indicated if large contact with spilled product is expected. Self-Contained Breathing Apparatus must be worn when approaching a fire in a confined space. Select fire fighter's clothing approved to relevant Standards (e.g. Europe: EN469).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with skin, eyes and clothing. Isolate hazard area and deny entry to unnecessary or unprotected personnel. Do not breathe fumes, vapour. Do not operate electrical equipment.

Small spill

For small liquid spills (< 1 drum), transfer by mechanical means to a labeled, sealable container for product recovery or safe disposal. Allow residues to evaporate or soak up with an appropriate absorbent material and dispose of safely. Remove contaminated soil and dispose of safely.

Large spill

For large liquid spills (> 1 drum), transfer by mechanical means such as vacuum truck to a salvage tank for recovery or safe disposal. Do not flush away residues with water. Retain as contaminated waste. Allow residues to evaporate or soak up with an appropriate absorbent material and dispose of safely. Remove contaminated soil and dispose of safely.

Environmental

Shut off leaks, if possible without personal risks. Remove all possible sources of ignition in the surrounding area. Use appropriate containment to avoid environmental contamination. Prevent from spreading or entering drains, ditches or rivers by using sand, earth, or other appropriate barriers. Attempt to disperse the vapour or to direct its flow to a safe location for example by using fog sprays. Take precautionary measures against static discharge. Ensure electrical continuity by bonding and grounding (earthing) all equipment. Monitor area with combustible gas indicator.

Cleanup methods

For small liquid spills (< 1 drum), transfer by mechanical means to a labeled, sealable container for product recovery or safe disposal. Allow residues to evaporate or soak up with an appropriate absorbent material and dispose of safely. Remove contaminated soil and dispose of safely. For large liquid spills (> 1 drum), transfer by mechanical means such as vacuum truck to a salvage tank for recovery or safe disposal. Do not flush away residues with water. Retain as contaminated waste. Allow residues to evaporate or soak up with an appropriate absorbent material and dispose of safely. Remove contaminated soil and dispose of safely. Ventilate contaminated area thoroughly.

Materials: appropriate absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid breathing of or direct contact with material. Only use in well ventilated areas. Wash thoroughly after handling. For guidance on selection of personal protective equipment see Section 8 of this Safety Data Sheet. Use the information in this data sheet as input to a risk assessment of local circumstances to help determine appropriate controls for safe handling, storage and disposal of this material. Ensure that all local regulations regarding handling and storage facilities are followed. Avoid inhaling vapour and/or mists. Avoid contact with skin, eyes and clothing. Extinguish any naked flames. Do not smoke. Remove ignition sources. Avoid sparks. When using do not eat or drink.

Storage

Storage Temperature: Ambient. Bulk storage tanks should be diked (bunded). Locate tanks away from heat and other sources of ignition. Must be stored in a diked (bunded) well-ventilated area, away from sunlight, ignition sources and other sources of heat. Keep away from aerosols, flammables, oxidizing agents, corrosives and from other flammable products which are not harmful or toxic to man or to the environment.

Hygiene

Wash hands before eating, drinking, smoking and using the toilet. Launder contaminated clothing before re-use. Do not ingest. If swallowed, then seek immediate medical assistance.

Fire prevention

Extinguish any naked flames. Do not smoke. Remove ignition sources. Avoid sparks. Locate tanks away from heat and other sources of ignition. Electrostatic discharge may cause fire.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Read in conjunction with the Exposure Scenario for your specific use contained in the Annex. The level of protection and types of controls necessary will vary depending upon potential exposure conditions. Select controls based on a risk assessment of local circumstances. Appropriate measures include: Use sealed systems as far as possible. Adequate explosion-proof ventilation to control airborne concentrations below the exposure guidelines/limits. Local exhaust ventilation is recommended. Firewater monitors and deluge systems are recommended. Eye washes and showers for emergency use. Where material is heated, sprayed or mist formed, there is greater potential for airborne concentrations to be generated. Ensure appropriate selection, testing and maintenance of equipment used to control exposure, e.g. personal protective equipment, local exhaust ventilation. Drain down system prior to equipment break-in or maintenance. Retain drain downs in sealed storage pending disposal or subsequent recycle.

Hands

Where hand contact with the product may occur the use of gloves approved to relevant standards (e.g. Europe: EN374, US: F739) made from the following materials may provide suitable chemical protection. Longer term protection: butyl-rubber Nitrile rubber gloves. Incidental contact/Splash protection: Nitrile rubber gloves. For continuous contact we recommend gloves with breakthrough time of more than 240 minutes with preference for >480 minutes where suitable gloves can be identified. For short-term/splash protection we recommend the same but recognize that suitable gloves offering this level of protection may not be available and in this case a lower breakthrough time maybe acceptable so long as appropriate maintenance and replacement regimes are followed. Glove thickness is not a good predictor of glove resistance to a chemical as it is dependent on the exact composition of the glove material. Glove thickness should be typically greater than 0.35 mm depending on the glove make and model. Suitability and durability of a glove is dependent on usage, e.g. frequency and duration of contact, chemical resistance of glove material, dexterity. Always seek advice from glove suppliers. Contaminated gloves should be replaced. Personal hygiene is a key element of effective hand care. Gloves must only be worn on clean hands. After using gloves, hands should be washed and dried thoroughly. Application of a non-perfumed moisturizer is recommended.

Eyes

If material is handled such that it could be splashed into eyes, protective eyewear is recommended. Approved to EU Standard EN166.

Respiratory

If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are unsuitable (e.g. airborne concentrations are high, risk of oxygen deficiency, confined space) use appropriate positive pressure breathing apparatus. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. If air-filtering respirators are suitable for conditions of use: Select a filter suitable for organic gases and vapours [Type A boiling point > 65°C (149°F)] meeting EN14387.

Skin/Body

Skin protection is not required under normal conditions of use. For prolonged or repeated exposures use impervious clothing over parts of the body subject to exposure. If repeated and/or prolonged skin exposure to the substance is likely, then wear suitable gloves tested to relevant Standard, and provide employee skin care programmes. Protective clothing approved to EU Standard EN14605. Wear antistatic and flame-retardant clothing, if a local risk assessment deems it so.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
colourless
Colour Intensity
---
Form
---
Odor
aromatic
Odor Threshold
Data not available
Ph
Not applicable
Melting Point
< 20 °C
Boiling Point
179 - 214 °C
Flash Point
Typical 62 - 65,6 °C
Freezing Point
Data not available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
1,0
Vapor Pressure
0,09 kPa (20 °C)
Vapor Density
---
Relative Density
0,88 - 0,91 (20 °C)
Bulk Density
---
Density
Typical 893 kg/m3 (15 °C)
Flammability
Data not available
Upper Explosive Limit
7 % (V)
Lower Explosive Limit
0,6 % (V)
Explosive Limits
---
Auto Ignition Temperature
449 - 510 °C
Decomposition Temperature
Not applicable
Solubility
insoluble
Partition Coefficient
Data not available
Solubility In Water
insoluble
Solubility In Fat
---
Molecular Weight
Data not available
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Data not available
Kinematic Viscosity
Typical 1,2 mm2/s (25 °C)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No hazardous reaction is expected when handled and stored according to provisions Stable under normal conditions of use.

Reactivity

The product does not pose any further reactivity hazards in addition to those listed in the following sub-paragraph.

Hazardous reactions

Reacts with strong oxidising agents.

Avoid

Avoid heat, sparks, open flames and other ignition sources. In certain circumstances product can ignite due to static electricity.

Incompatible

Strong oxidising agents.

Decomposition

Hazardous decomposition products are not expected to form during normal storage. Thermal decomposition is highly dependent on conditions. A complex mixture of airborne solids, liquids and gases including carbon monoxide, carbon dioxide, sulphur oxides and unidentified organic compounds will be evolved when this material undergoes combustion or thermal or oxidative degradation.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
3082
Shipping Name
ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (Hydrocarbons, C10, aromatics)
Transport Class
9
Packing Group
III
ADR

Refer to Section 7, Handling & Storage, for special precautions which a user needs to be aware of or needs to comply with in connection with transport.

IMDG

Refer to Section 7, Handling & Storage, for special precautions which a user needs to be aware of or needs to comply with in connection with transport.

IATA

Refer to Section 7, Handling & Storage, for special precautions which a user needs to be aware of or needs to comply with in connection with transport.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is ShellSol A150 known by?

ShellSol A150 is also known as: Hydrocarbons, C10, aromatics, >1% naphthalene

What is the hazard signal word for ShellSol A150?

The signal word is danger.

What is the physical form of ShellSol A150?

ShellSol A150 is a liquid. with colourless color. It has aromatic odor.

What is the solubility of ShellSol A150?

insoluble

What is ShellSol A150 used for?

Industrial Solvent. Please refer to section 16 and/or the annexes for the registered uses under REACH.

What are the hazard statements for ShellSol A150?

This substance has 4 hazard statements:

  • H304: May be fatal if swallowed and enters airways.
  • H336: May cause drowsiness or dizziness.
  • H351: Suspected of causing cancer.
  • H411: Toxic to aquatic life with long lasting effects.

What is the melting point of ShellSol A150?

The melting point is < 20 °C and the boiling point is 179 - 214 °C.