NextSDS Logo
Safety Data Sheet EN

RADIACID 0210

CAS 67701-08-0
EC 266-932-7

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RADIACID 0210
Product Form
Substance (UVCB)
Chemical Name
Fatty acids, C16-18 (even numbered) and C18-unsatd.

Regulatory Identifiers

CAS Number
67701-08-0 Check regulations →
EC Number
266-932-7 Check regulations →
REACH No.
1907/2006/EC Annex V.9

Identified Uses

Industrial use

Manufacturers & Suppliers

OLEON N.V. logo

OLEON N.V.

manufacturer

Assenedestraat 2 9940 Ertvelde - Belgium

+32 9 341 10 11

www.oleon.com

Emergency Contacts

SGS ERS

+32 3 575 55 55

24/7

SGS ERS

+1 888 765 6554

24/7

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type uvcb
Chemical Name CAS Number Concentration Hazardous
Fatty acids, C16-18 and C18-unsatd. EC: 266-932-7 67701-08-0 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Skin contact

Wash immediately with lots of water. Soap may be used. Take victim to a doctor if irritation persists.

Eye contact

Rinse immediately with plenty of water. Take victim to an ophthalmologist if irritation persists.

Ingestion

Rinse mouth with water. Call Poison Information Centre (www.who.int/ipcs/poisons/centre/directory/en). Consult a doctor/medical service if you feel unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

AFFF foam. BC powder. Carbon dioxide. Dry sand. Dry chemical powder. Adapt extinguishing media to the environment.

Unsuitable media

Solid water jet ineffective as extinguishing medium.

Specific hazards

DIRECT FIRE HAZARD: Combustible. INDIRECT FIRE HAZARD: Heating increases the fire hazard. Temperature above flashpoint: higher fire/explosion hazard. DIRECT EXPLOSION HAZARD: Fine dust is explosive with air. INDIRECT EXPLOSION HAZARD: Dust cloud can be ignited by a spark.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Mark the danger area. Exposure to heat: have neighbourhood close doors and windows. Exposure to fire/heat: consider evacuation. Wash contaminated clothes.

Environmental

Prevent soil and water pollution.

Cleanup methods

Carefully collect the spill/leftovers. If melted: allow liquid to solidify before taking it up. Scoop solid spill into closing containers or into synthetic bags. Clean contaminated surfaces with an excess of water and soap solution.

Materials: closing containers or synthetic bags, water and soap solution

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handling temperature: ≥ 10 °C above melting point

Storage

Keep container in a well-ventilated place. Store at ambient temperature. Keep out of direct sunlight. Meet the legal requirements.

Fire prevention

KEEP SUBSTANCE AWAY FROM: ignition sources.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Gloves.

Eyes

Safety glasses.

Skin/Body

Protective clothing. Materials for protective clothing: GIVE GOOD RESISTANCE: nitrile rubber

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Lower Explosive Limit
---
Solubility In Water
< 0,005 g/100ml (25°C)
Kinematic Viscosity
ca. 16,9 mm²/s (40°C)
Solubility In Fat
Soluble in oils/fats.
Appearance
Liquid.
Crystallisation Point
---
Vapor Density
---
Softening Point
---
Evaporation Rate
---
Relative Density
No data available
Partition Coefficient
> 5 (est.)
Voc Content
---
Solidification Point
---
Upper Explosive Limit
---
Form
---
Dynamic Viscosity
No data available
Decomposition Temperature
No data available
Boiling Point
> 250 °C
Auto Ignition Temperature
ca. 345 °C
Cloud Point
---
Odor
Characteristic odour. Mild odour.
Flash Point
> 180 °C
Solubility
Water: < 0,005 g/100ml (25°C). Poorly soluble in water. Soluble in oils/fats. soluble in most organic solvents.
Relative Evaporation Rate
No data available
Properties Status
---
Melting Point
No supplementary information available
State Under Standard Conditions
---
Explosive Limits
---
Ph
< 7
Flammability
No data available
Metal Corrosion
---
Colour Intensity
---
Molecular Weight
---
Density
0.85 to 0.90
Bulk Density
---
Freezing Point
ca. 6 °C
Physical State Data
liquid
Odor Threshold
No data available
Vapor Pressure
< 0,01 hPa
Colour
Light yellow to dark yellow.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

On burning: release of (carbon monoxide - carbon dioxide).

Hazardous reactions

No additional information available

Avoid

No supplementary information available.

Incompatible

No supplementary information available.

Decomposition

No supplementary information available.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RADIACID 0210?

The signal word is no signal word.

What is the physical form of RADIACID 0210?

RADIACID 0210 is a liquid appearing as liquid. with light yellow to dark yellow. color. It has characteristic odour. mild odour. odor.

What is the solubility of RADIACID 0210?

Water: < 0,005 g/100ml (25°C). Poorly soluble in water. Soluble in oils/fats. soluble in most organic solvents.

What is RADIACID 0210 used for?

Industrial use

What is the melting point of RADIACID 0210?

The melting point is No supplementary information available and the boiling point is > 250 °C.

Compliance Scanner

Scan your compliance