NextSDS Logo
Safety Data Sheet EN

RADIACID 0212

CAS 67701-08-0
EC 266-932-7

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
RADIACID 0212
Product Form
Substance (UVCB)
Chemical Name
Fatty acids, C16-18 (even numbered) and C18-unsatd.

Regulatory Identifiers

CAS Number
67701-08-0 Check regulations →
EC Number
266-932-7 Check regulations →
REACH No.
1907/2006/EC Annex V.9

Identified Uses

Industrial use

Manufacturers & Suppliers

OLEON N.V. logo

OLEON N.V.

manufacturer

Assenedestraat 2 9940 Ertvelde - Belgium

+32 9 341 10 11

www.oleon.com

Emergency Contacts

SGS ERS

+32 3 575 55 55

24/7

SGS ERS

+1 888 765 6554

24/7

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type uvcb

Fatty acids, C16-18 and C18-unsatd. at 100%

Chemical Name CAS Number Concentration Hazardous
Fatty acids, C16-18 and C18-unsatd. EC: 266-932-7 67701-08-0 100% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove the victim into fresh air. Respiratory problems: consult a doctor/medical service.

Symptoms: ON HEATING: Irritation of the respiratory tract.

Skin contact

Wash immediately with lots of water. Soap may be used. Take victim to a doctor if irritation persists.

Eye contact

Rinse immediately with plenty of water. Take victim to an ophthalmologist if irritation persists.

Ingestion

Rinse mouth with water. Call Poison Information Centre (www.who.int/ipcs/poisons/centre/directory/en). Consult a doctor/medical service if you feel unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

AFFF foam. BC powder. Carbon dioxide. Dry sand. Dry chemical powder. Adapt extinguishing media to the environment.

Unsuitable media

Solid water jet ineffective as extinguishing medium.

Specific hazards

DIRECT FIRE HAZARD: Combustible. INDIRECT FIRE HAZARD: Heating increases the fire hazard. Temperature above flashpoint: higher fire/explosion hazard. DIRECT EXPLOSION HAZARD: Fine dust is explosive with air. INDIRECT EXPLOSION HAZARD: Dust cloud can be ignited by a spark.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Mark the danger area. Exposure to heat: have neighbourhood close doors and windows. Exposure to fire/heat: consider evacuation. Wash contaminated clothes.

Environmental

Prevent soil and water pollution.

Cleanup methods

Carefully collect the spill/leftovers. If melted: allow liquid to solidify before taking it up. Scoop solid spill into closing containers or into synthetic bags. Clean contaminated surfaces with an excess of water and soap solution.

Materials: closing containers or synthetic bags, water and soap solution

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Storage

Store at ambient temperature. Keep out of direct sunlight. Meet the legal requirements.

Fire prevention

KEEP SUBSTANCE AWAY FROM: ignition sources.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Gloves. GIVE GOOD RESISTANCE: nitrile rubber

Eyes

Safety glasses.

Skin/Body

Protective clothing. GIVE GOOD RESISTANCE: nitrile rubber

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Melting Point
No supplementary information available
Partition Coefficient
> 5 (est.)
Kinematic Viscosity
ca. 16,9 mm²/s (40°C)
Flash Point
> 180 °C
Upper Explosive Limit
---
Vapor Density
---
Appearance
Liquid.
Boiling Point
> 250 °C
Solubility
Water: < 0,005 g/100ml (25°C)
Molecular Weight
---
Relative Density
No data available
Solubility In Water
< 0,005 g/100ml (25°C)
Auto Ignition Temperature
ca. 345 °C
Voc Content
< 0,1 % (1999/13/EC; 2004/42/EC; 2010/75/EU)
Odor Threshold
No data available
Colour
Light yellow to dark yellow.
Bulk Density
---
Form
---
Solubility In Fat
Soluble in oils/fats.
Density
ca. 891,2 kg/m³ (20°C) ca. 877,4 kg/m³ (40°C) ca. 836,1 kg/m³ (100°C)
Softening Point
---
Lower Explosive Limit
---
Freezing Point
ca. 6 °C
Cloud Point
---
Solidification Point
---
Dynamic Viscosity
No data available
Ph
< 7
Relative Evaporation Rate
No data available
Odor
Characteristic odour. Mild odour.
Evaporation Rate
---
Vapor Pressure
< 0,01 hPa (20°C)
Colour Intensity
---
Flammability
No data available
Decomposition Temperature
> 300 °C
Metal Corrosion
---
State Under Standard Conditions
---
Properties Status
---
Explosive Limits
---
Physical State Data
liquid
Crystallisation Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

On burning: release of (carbon monoxide - carbon dioxide).

Hazardous reactions

No additional information available

Avoid

No supplementary information available.

Incompatible

No supplementary information available.

Decomposition

No supplementary information available.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not applicable
Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for RADIACID 0212?

The signal word is no signal word.

What is the physical form of RADIACID 0212?

RADIACID 0212 is a liquid appearing as liquid. with light yellow to dark yellow. color. It has characteristic odour. mild odour. odor.

What is the solubility of RADIACID 0212?

Water: < 0,005 g/100ml (25°C)

What is RADIACID 0212 used for?

Industrial use

What is the melting point of RADIACID 0212?

The melting point is No supplementary information available and the boiling point is > 250 °C.

Compliance Scanner