NextSDS Logo
Safety Data Sheet EN

MOBIL RARUS PE R-C 220

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MOBIL RARUS PE R-C 220
Product Form
base oil and additives

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Compressor oil

Uses advised against

This product is not recommended for any industrial, professional or consumer use other than the Identified Uses above.

Manufacturers & Suppliers

E

ExxonMobil International LLC Taiwan Branch

national supplier

6th Floor, No 2, Section 1, Tun Hua South Road, IBM Building, Taipei Taiwan

886-2-2734-6888

Emergency Contacts

CHEMTREC

00801-49-1821

CHEMTREC

+886 2 7741 4207

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Aquatic Acute Cat. 3
Aquatic Chronic Cat. 3

GHS Pictograms

Hazard Statements

H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P273 Avoid release to the environment.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

Chemical Name CAS Number Concentration Hazardous
2,6-di-tert-butyl-p-cresol 128-37-0 2.5% Yes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing.

Symptoms: No known significant effects or critical hazards. No specific data.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. If product is injected into or under the skin, or into any part of the body, regardless of the appearance of the wound or its size, the individual should be evaluated immediately by a physician as a surgical emergency. Even though initial symptoms from high pressure injection may be minimal or absent, early surgical treatment within the first few hours may significantly reduce the ultimate extent of injury.

Symptoms: No known significant effects or critical hazards. Local necrosis as evidenced by delayed onset of pain and tissue damage a few hours after injection.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Symptoms: No known significant effects or critical hazards. No specific data.

Ingestion

Wash out mouth with water. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel.

Symptoms: No known significant effects or critical hazards. No specific data.

Immediate Medical Attention

If product is injected into or under the skin, or into any part of the body, the individual should be evaluated immediately by a physician as a surgical emergency. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam.

Unsuitable media

Do not use water jet.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst. This material is harmful to aquatic life with long lasting effects. Fire water contaminated with this material must be contained and prevented from being discharged to any waterway, sewer or drain.

Instructions

Use standard firefighting procedures and consider the hazards of other involved materials. Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. Assure an extended cooling down period to prevent reignition. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Approach the release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilt product. Confine the spill immediately with booms. Remove from the surface by skimming or with suitable absorbents. Seek the advice of a specialist before using dispersants. Warn other shipping.

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material. Wash spillages into an effluent treatment plant. Remove from the surface by skimming or with suitable absorbents.

Materials: non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing vapour or mist. Avoid release to the environment. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.

Storage

Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabelled containers. Use appropriate containment to avoid environmental contamination.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

This material is a static accumulator. A liquid is typically considered a nonconductive, static accumulator if its conductivity is below 100 pS/m (100x10E-12 Siemens per meter) and is considered a semiconductive, static accumulator if its conductivity is below 10,000 pS/m.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Evaporation Rate
Not available.
Auto Ignition Temperature
Not available.
Vapor Pressure
<0.1 mm Hg [20 °C] [Estimated]
Voc Content
---
Upper Explosive Limit
7% [Estimated]
Metal Corrosion
---
Ph
Not applicable.
Properties Status
---
Colour
Colourless
Solubility In Water
Negligible
Relative Density
0.876 [ASTM D4052]
Odor
Characteristic
Explosive Limits
---
Solubility
---
Lower Explosive Limit
0.9% [Estimated]
Flash Point
Open cup: >200°C (>392°F) [ASTM D-92]
Cloud Point
---
Crystallisation Point
---
Molecular Weight
---
State Under Standard Conditions
---
Dynamic Viscosity
---
Form
---
Vapor Density
---
Freezing Point
Not available.
Relative Evaporation Rate
---
Decomposition Temperature
Not available.
Solubility In Fat
---
Softening Point
---
Partition Coefficient
>3.5 [Estimated]
Solidification Point
---
Odor Threshold
Not available.
Colour Intensity
---
Appearance
---
Boiling Point
>315.56°C (>600°F) [Estimated]
Physical State
Liquid.
Kinematic Viscosity
226 cSt [40 °C] [ASTM D 445]
Flammability
Ignitable
Physical State Data
liquid
Melting Point
Not available.
Bulk Density
---
Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

High energy sources of ignition. Excessive heat.

Incompatible

Strong oxidisers

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not regulated.
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This material is considered hazardous according to The Regulations on Labelling and Hazard Communications for Hazardous Materials.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MOBIL RARUS PE R-C 220?

The signal word is no signal word.

What is the physical form of MOBIL RARUS PE R-C 220?

MOBIL RARUS PE R-C 220 is a liquid. with colourless color. It has characteristic odor.

What is MOBIL RARUS PE R-C 220 used for?

Compressor oil

What are the hazard statements for MOBIL RARUS PE R-C 220?

This substance has 1 hazard statement:

  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of MOBIL RARUS PE R-C 220?

The melting point is Not available. and the boiling point is >315.56°C (>600°F) [Estimated].