NextSDS Logo
Safety Data Sheet EN

MESAMOLL

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MESAMOLL
Product Code
000000000000402133

Regulatory Identifiers

CAS Number
N/A

Identified Uses

plastics additive, Rubber

Manufacturers & Suppliers

L

LANXESS Corporation

manufacturer

111 RIDC Park West Drive, Pittsburgh, Pennsylvania 15275-1112

(800) LANXESS

Emergency Contacts

CHEMTREC

(800) 424-9300

CHEMTREC

(703) 527-3887

Lanxess

(800) 410-3063

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Alkyl sulphonic acid ester of phenol

Notes

No hazardous ingredients

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. Get medical attention if symptoms occur.

Skin contact

Wash off with soap and water. Get medical attention if symptoms occur.

Eye contact

Immediately flush eye(s) with plenty of water. Remove contact lenses. Get medical attention if symptoms appear.

Ingestion

Rinse mouth with water. Do not induce vomiting unless directed to do by medical personnel. Get medical attention if symptoms occur.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.

Unsuitable media

None known.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Use personal protective equipment.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Wash spillages into an effluent treatment plant or proceed as follows. Soak up with non-combustible absorbent material and transfer to a container for disposal.

Materials: non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Remove contaminated clothing and protective equipment before entering eating areas. Workers should wash hands and face before eating, drinking and smoking. Put on appropriate personal protection equipment. Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed.

Storage

Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container closed when not in use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.

Hygiene

Remove contaminated clothing and protective equipment before entering eating areas. Workers should wash hands and face before eating, drinking and smoking. Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

If user operations generate dust, fumes or mist, use ventilation to keep exposure to airborne contaminants below the exposure limit.

Hands

Wearing time : < 60 min; Material : Polyvinyl chloride - PVC; Material : Nitrile rubber - NBR; Remarks : Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough.

Eyes

Safety glasses with side-shields

Respiratory

Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. The following respirator is recommended if airborne concentrations exceed the appropriate standard/guideline. NIOSH approved, air-purifying organic vapor respirator.

Skin/Body

Wear suitable protective clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Appearance
Clear viscous liquid.
Odor Threshold
No data available
Evaporation Rate
No data available
Colour
yellow
Upper Explosive Limit
No data available
Flash Point
410 - 464 °F / 210 - 240 °C
Dynamic Viscosity
122.9 mPa.s (68 °F / 20 °C)
Solubility In Fat
---
Partition Coefficient
log Pow: 5.7 - 11.3
Voc Content
---
State Under Standard Conditions
---
Explosive Limits
---
Physical State
liquid
Relative Evaporation Rate
---
Cloud Point
---
Properties Status
---
Kinematic Viscosity
No data available
Crystallisation Point
---
Ph
No data available
Relative Density
No data available
Flammability
---
Solubility
---
Auto Ignition Temperature
No data available
Colour Intensity
---
Decomposition Temperature
> 572 °F / > 300 °C
Density
1.04 - 1.07 g/cm3 (68 °F / 20 °C)
Metal Corrosion
---
Solidification Point
---
Form
---
Lower Explosive Limit
No data available
Softening Point
---
Melting Point
No data available
Freezing Point
---
Bulk Density
---
Physical State Data
liquid
Molecular Weight
---
Vapor Pressure
< 0.0001 hPa (68 °F / 20 °C) < 0.0001 hPa (77 °F / 25 °C)
Vapor Density
---
Boiling Point
572 - 752 °F / 300 - 400 °C
Solubility In Water
0.0022 g/l
Odor
odorless
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

No data available

Incompatible

No specific data.

Decomposition

No decomposition if stored and applied as directed.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimized wherever possible.

Disposal

If discarded in its purchased form, this product would not be a hazardous waste either by listing or by characteristic. However, under RCRA, it is the responsibility of the product user to determine at the time of disposal, whether a material containing the product or derived from the product should be classified as a hazardous waste.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MESAMOLL?

The signal word is no signal word.

What is the physical form of MESAMOLL?

MESAMOLL is a liquid appearing as clear viscous liquid. with yellow color. It has odorless odor.

What is MESAMOLL used for?

plastics additive, Rubber

What is the melting point of MESAMOLL?

The melting point is No data available and the boiling point is 572 - 752 °F / 300 - 400 °C.