Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- LIALET 125/5
- Chemical Name
- Alcohols, C12-15-branched and linear, ethoxylated (>2.5 moles EO)
Regulatory Identifiers
- CAS Number
- 106232-83-1 Check regulations →
Identified Uses
raw material for washing and cleaning agents, Industrial use
Manufacturers & Suppliers
Sloveca, Sasol Slovakia, spol. s r.o.
manufacturer
Mostová 2, 811 02 Bratislava, Slovak Republic
+421 2 54430219
Emergency Contacts
Emergency Contact
+421 902 899981
24 hours
National Toxicological Information Centre
+421 25 477 4166
24 hours
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Alcohols, C12-15- branched and linear, ethoxylated (>= 2.5 EO) EC: 932-186-2 | 106232-83-1 | 90 - 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove from exposure, lie down. If breathing is irregular or stopped, administer artificial respiration. Monitor breathing, give oxygen if necessary. Consult a physician.
Wash off immediately with plenty of water. Consult a physician if necessary.
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
Consult a physician. Do not induce vomiting without medical advice. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Consult a physician.
Medical Treatment
No information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, Dry powder, Foam, Carbon dioxide (CO2)
Dangerous gases or fumes may occur in case of fire.
Standard procedure for chemical fires.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid subsoil penetration. Do not flush into surface water or sanitary sewer system.
Soak up with inert absorbent material
Materials: sand, silica gel, acid binder, universal binder, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Wear personal protective equipment. Avoid contact with skin and eyes.
Keep tightly closed in a dry and cool place.
Normal measures for preventive fire protection. Do not spray on a naked flame or any incandescent material.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
The choice of an appropriate glove does not only depend on its material but also on other quality features and is different from one producer to the other. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. Be aware that in daily use the durability of a chemical resistant protective glove can be notably shorter than the break through time measured according to EN 374, due to the numerous outside influences (e.g. temperature). gloves suitable for permanent contact: Material: butyl-rubber, Break through time: >= 480 min, Layer thickness: >= 0,7 mm. gloves suitable for splash protection: Material: Nitrile rubber/nitrile latex, Break through time: >= 30 min, Layer thickness: >= 0,4 mm.
Tightly fitting safety goggles, Safety glasses with side-shields
No personal respiratory protective equipment normally required. In inadequately ventilated areas, where workplace limits are exceeded, where unpleasant odours exist or where aerosols are in use, or smoke and mist occur, use self-contained breathing apparatus or breathing apparatus with a type A filter or appropriate combined filter (e.g. where aerosols are in use, or smoke and mist occur, A-P2 or ABEK-P2), in compliance with EN 141.
Wear suitable protective equipment.
Avoid subsoil penetration. Do not flush into surface water or sanitary sewer system.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if stored and applied as directed.
Stable at normal ambient temperature and pressure.
None known.
Direct heating, dirt, chemical contamination, sunlight, UV or ionising radiation.
Strong acids and oxidizing agents;
No decomposition if stored and applied as directed. Thermal decomposition: Hazardous decomposition products formed under fire conditions.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Can be incinerated, when in compliance with local regulations.
Can be incinerated, when in compliance with local regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3082
- Shipping Name
- ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S. (Fatty alcohol polyethoxylated)
- Transport Class
- 9
- Packing Group
- III
Labels 9
Labels 9MI
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Employment restrictions for children and young workers in accordance with Directive 94/33/EC and the respective national provisions are to be observed.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for LIALET 125/5?
The signal word is danger.
What is the physical form of LIALET 125/5?
LIALET 125/5 is a liquid; 25 °c; with cloudy color. It has characteristic odor.
What is LIALET 125/5 used for?
raw material for washing and cleaning agents, Industrial use
What are the hazard statements for LIALET 125/5?
This substance has 2 hazard statements:
- H318: Causes serious eye damage.
- H410: Very toxic to aquatic life with long lasting effects.