Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Pluriol® E 400 LS-FLEX
Chemical Name
polyethylene glycol

Regulatory Identifiers

CAS Number
25322-68-3 Check regulations →

Identified Uses

Raw material for the chemical-technical industry

Manufacturers & Suppliers

B

BASF SE

manufacturer

67056 Ludwigshafen, GERMANY

+49 621 60-44676

Emergency Contacts

International emergency number

+49 180 2273-112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

polyethylene glycol

Chemical Name CAS Number Concentration Hazardous
polyethylene glycol 25322-68-3 --- No

Notes

No particular hazards known.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Keep patient calm, remove to fresh air, seek medical attention.

Skin contact

Remove contaminated clothing. Wash thoroughly with soap and water.

Eye contact

Wash affected eyes for at least 15 minutes under running water with eyelids held open.

Ingestion

Rinse mouth and then drink 200-300 ml of water.

Medical Treatment

Symptomatic treatment (decontamination, vital functions).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

water spray, dry powder, foam

Specific hazards

harmful vapours. Evolution of fumes/fog. The substances/groups of substances mentioned can be released in case of fire.

Firefighter Protection

Wear a self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protective clothing. Information regarding personal protective measures, see section 8.

Small spill

For residues: Pick up with suitable absorbent material.

Large spill

For large amounts: Pump off product.

Environmental

Contain contaminated water/firefighting water. Do not discharge into drains/surface waters/groundwater.

Cleanup methods

For large amounts: Pump off product. For residues: Pick up with suitable absorbent material.

Materials: suitable absorbent material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures necessary provided product is used correctly.

Storage

Keep container tightly closed and dry; store in a cool place.

Fire prevention

No special precautions necessary.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Chemical resistant protective gloves (EN 374) Suitable materials also with prolonged, direct contact (Recommended: Protective index 6, corresponding > 480 minutes of permeation time according to EN 374): nitrile rubber (NBR) - 0.4 mm coating thickness Supplementary note: The specifications are based on tests, literature data and information of glove manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g. temperature) it must be considered, that the practical usage of a chemical-protective glove in practice may be much shorter than the permeation time determined through testing. Manufacturer's directions for use should be observed because of great diversity of types.

Eyes

Safety glasses with side-shields (frame goggles) (e.g. EN 166)

Respiratory

Respiratory protection in case of vapour/aerosol release. Particle filter with medium efficiency for solid and liquid particles (e.g. EN 143 or 149, Type P2 or FFP2)

Skin/Body

Body protection must be chosen based on level of activity and exposure.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Lower Explosive Limit
For liquids not relevant for classification and labelling., The lower explosion point may be 5 - 15 °C below the flash point.
Boiling Point
> 148 °C
Colour
clear
Upper Explosive Limit
For liquids not relevant for classification and labelling.
Colour Intensity
---
Kinematic Viscosity
---
Flash Point
238 °C
Solidification Point
---
Solubility
---
Solubility In Water
fully soluble
Explosive Limits
---
Dynamic Viscosity
6,8 - 8 mPa.s
Properties Status
---
Relative Evaporation Rate
---
Physical State Data
liquid
Odor
mild, almost odourless
Form
liquid
Solubility In Fat
---
State Under Standard Conditions
---
Bulk Density
---
Vapor Pressure
< 0,35 mmHg
Melting Point
---
Voc Content
---
Auto Ignition Temperature
not determined
Appearance
---
Metal Corrosion
---
Softening Point
---
Molecular Weight
---
Flammability
not determined
Density
1,1227 g/cm³
Crystallisation Point
---
Freezing Point
approx. 5 °C
Cloud Point
---
Physical State
liquid
Relative Density
No data available.
Ph
> 6
Decomposition Temperature
not determined
Odor Threshold
not determined
Partition Coefficient
-2,3
Evaporation Rate
not determined
Vapor Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable.

Reactivity

Corrosion to metals: No corrosive effect on metal.

Avoid

See MSDS section 7 - Handling and storage.

Incompatible

strong acids, strong bases, strong oxidizing agents, reactive chemicals

Decomposition

No hazardous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must be disposed of or incinerated in accordance with local regulations.

Disposal

Must be disposed of or incinerated in accordance with local regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not applicable
Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Pluriol® E 400 LS-FLEX?

The signal word is no signal word.

What is the physical form of Pluriol® E 400 LS-FLEX?

Pluriol® E 400 LS-FLEX is a liquid with clear color. It has mild, almost odourless odor.

What is Pluriol® E 400 LS-FLEX used for?

Raw material for the chemical-technical industry