NextSDS Logo
Safety Data Sheet EN

B155454

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
B155454

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Passenger Car Oils

Uses advised against

None identified.

Manufacturers & Suppliers

LUBRIZOL FRANCE logo

LUBRIZOL FRANCE

manufacturer

25 QUAI DE FRANCE, CS 61062, 76173 ROUEN CEDEX, 76173, FR

(33) 02.35.58.14.00

http://www.mylubrizol.com

Emergency Contacts

CHEMTREC

(+1) 703 527 3887

WITHIN FRANCE

09.75.18.14.07

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Aquatic Chronic Cat. 3 H412

GHS Pictograms

Hazard Statements

H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P273 Avoid release to the environment.
P501 Dispose of contents/ container to an approved facility in accordance with local, regional, national and international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Mineral oil --- 20 - 50% Yes
reaction mass of isomers of: C7-9-alkyl 3-(3,5-di-trans-butyl-4-hydroxyphenyl)propionate EC: 406-040-9 --- 5 - 10% Yes
zinc O,O,O',O'-tetrakis(1,3-dimethylbutyl) bis(phosphorodithioate) EC: 218-679-9 --- 3 - 5% Yes
Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 --- 1 - 10% Yes
Phosphorodithioic acid, mixed O,O-bis(1,3-dimethylbutyl and iso-Pr)esters, zinc salts EC: 283-392-8 --- 1 - 2.5% Yes
Reaction products of boric acid with 2-propylheptan-1-ol (1:3) EC: 806-750-2 --- 1 - 5% Yes
C14-16-18 Alkyl phenol EC: 931-468-2 --- 0.1 - 1% Yes

Notes

600, 700 and 900 ECHA List Numbers do not have any legal significance; rather they are purely technical identifiers and are displayed for informational purposes only.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove exposed person to fresh air if adverse effects are observed.

Skin contact

Take off contaminated clothing and wash before re-use. Wash with soap and water. If skin irritation occurs, get medical attention. Get medical attention if symptoms occur. Launder contaminated clothing before reuse.

Eye contact

Flush thoroughly with water. If irritation occurs, get medical assistance. Remove contact lenses, if present and easy to do. Continue rinsing.

Ingestion

Rinse mouth. Get medical attention if symptoms occur.

Immediate Medical Attention

If irritation occurs, get medical assistance. Get medical attention if symptoms occur.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material.

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

A solid stream of water will spread the burning material. Material creates a special hazard because it floats on water. See section 10 for additional information.

Instructions

No data available.

Firefighter Protection

Wear full protective firegear including self-containing breathing apparatus operated in the positive pressure mode with full facepiece, coat, pants, gloves and boots.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Large spill

Dike far ahead of larger spill for later recovery and disposal.

Environmental

Avoid release to the environment. Prevent further leakage or spillage if safe to do so.

Cleanup methods

Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.

Materials: inert material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe good industrial hygiene practices. Provide adequate ventilation. Wear appropriate personal protective equipment. Avoid environmental contamination. In case of spills, beware of slippery floors and surfaces. Use grounding and bonding connection when transferring material. Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures. Keep container closed when not in use and use with adequate ventilation.

Storage

Store away from incompatible materials. See section 10 for incompatible materials. Odorous and toxic fumes may form from the decomposition of this product. Do not store product at temperature in excess of 45°C (113°F) for extended periods of time, 1 week or more; or, using a heat source, such as steam, at a temperature in excess of 100°C (212°F).

Hygiene

Observe good industrial hygiene practices.

Fire prevention

Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special requirements under ordinary conditions of use and with adequate ventilation. Material should be handled in enclosed vessels and equipment, in which case general (mechanical) room ventilation should be sufficient. Local exhaust ventilation should be used at points where dust, mist, vapors or gases can escape into the room air.

Hands

Use nitrile or neoprene gloves. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm.

Eyes

If contact is likely, safety glasses with side shields are recommended. Eye protection should meet the standards set out in EN 166.

Respiratory

A respiratory protection program compliant with all applicable regulations must be followed whenever workplace conditions require the use of a respirator. Under normal use conditions, respirator is not usually required. Use appropriate respiratory protection if exposure to dust particles, mist or vapors is likely. Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill clean-up sites. Use disposable dust/mist mask if the recommended exposure limit is exceeded. Use respirator with an organic vapor cartridge if exposure limit is exceeded. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment.

Environmental

No data available. See section 6 for details.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor
Characteristic
Physical State
liquid
Properties Status
---
Appearance
Dark amber
Freezing Point
No data available.
Kinematic Viscosity
2419 mm2/s (40 °C)
Cloud Point
---
Metal Corrosion
---
Relative Density
0.932 - 0.972 (15.6 °C)
Vapor Density
---
Odor Threshold
No data available.
Colour Intensity
---
Boiling Point
No data available.
Solubility In Fat
---
Evaporation Rate
No data available.
Voc Content
No data available.
Solubility
No data available.
Dynamic Viscosity
---
Bulk Density
---
Upper Explosive Limit
No data available.
Form
liquid
Explosive Limits
---
Auto Ignition Temperature
No data available.
Softening Point
---
Relative Evaporation Rate
---
Decomposition Temperature
No data available.
Lower Explosive Limit
No data available.
Physical State Data
liquid
Molecular Weight
---
Flash Point
151 °C
Ph
Not applicable
Crystallisation Point
---
Solidification Point
---
Vapor Pressure
No data available.
Flammability
No data available.
Partition Coefficient
No data available.
Solubility In Water
Insoluble in water
Colour
Dark amber
State Under Standard Conditions
---
Melting Point
---
Density
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

No data available.

Hazardous reactions

Will not occur.

Avoid

Do not expose to excessive heat, ignition sources, or oxidizing materials. Excessive heat.

Incompatible

Strong oxidizing agents. Strong mineral acids and strong oxidizing agents.

Decomposition

Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, nitrogen oxides, and other products of incomplete combustion.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations.

Disposal

Dispose of packaging or containers in accordance with local, regional, national and international regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for B155454?

The signal word is no signal word.

What is the physical form of B155454?

B155454 is a liquid appearing as dark amber with dark amber color. It has characteristic odor.

What is the solubility of B155454?

No data available.

What is B155454 used for?

Passenger Car Oils

What are the hazard statements for B155454?

This substance has 1 hazard statement:

  • H412: Harmful to aquatic life with long lasting effects.