Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- B155454
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Passenger Car Oils
Uses advised against
None identified.
Manufacturers & Suppliers
LUBRIZOL FRANCE
manufacturer
25 QUAI DE FRANCE, CS 61062, 76173 ROUEN CEDEX, 76173, FR
(33) 02.35.58.14.00
http://www.mylubrizol.com
Emergency Contacts
CHEMTREC
(+1) 703 527 3887
WITHIN FRANCE
09.75.18.14.07
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Mineral oil | --- | 20 - 50% | Yes |
| reaction mass of isomers of: C7-9-alkyl 3-(3,5-di-trans-butyl-4-hydroxyphenyl)propionate EC: 406-040-9 | --- | 5 - 10% | Yes |
| zinc O,O,O',O'-tetrakis(1,3-dimethylbutyl) bis(phosphorodithioate) EC: 218-679-9 | --- | 3 - 5% | Yes |
| Distillates (petroleum), hydrotreated heavy paraffinic EC: 265-157-1 | --- | 1 - 10% | Yes |
| Phosphorodithioic acid, mixed O,O-bis(1,3-dimethylbutyl and iso-Pr)esters, zinc salts EC: 283-392-8 | --- | 1 - 2.5% | Yes |
| Reaction products of boric acid with 2-propylheptan-1-ol (1:3) EC: 806-750-2 | --- | 1 - 5% | Yes |
| C14-16-18 Alkyl phenol EC: 931-468-2 | --- | 0.1 - 1% | Yes |
Notes
600, 700 and 900 ECHA List Numbers do not have any legal significance; rather they are purely technical identifiers and are displayed for informational purposes only.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove exposed person to fresh air if adverse effects are observed.
Take off contaminated clothing and wash before re-use. Wash with soap and water. If skin irritation occurs, get medical attention. Get medical attention if symptoms occur. Launder contaminated clothing before reuse.
Flush thoroughly with water. If irritation occurs, get medical assistance. Remove contact lenses, if present and easy to do. Continue rinsing.
Rinse mouth. Get medical attention if symptoms occur.
Immediate Medical Attention
If irritation occurs, get medical assistance. Get medical attention if symptoms occur.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material.
Do not use water jet as an extinguisher, as this will spread the fire.
A solid stream of water will spread the burning material. Material creates a special hazard because it floats on water. See section 10 for additional information.
No data available.
Firefighter Protection
Wear full protective firegear including self-containing breathing apparatus operated in the positive pressure mode with full facepiece, coat, pants, gloves and boots.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Dike far ahead of larger spill for later recovery and disposal.
Avoid release to the environment. Prevent further leakage or spillage if safe to do so.
Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.
Materials: inert material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Observe good industrial hygiene practices. Provide adequate ventilation. Wear appropriate personal protective equipment. Avoid environmental contamination. In case of spills, beware of slippery floors and surfaces. Use grounding and bonding connection when transferring material. Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures. Keep container closed when not in use and use with adequate ventilation.
Store away from incompatible materials. See section 10 for incompatible materials. Odorous and toxic fumes may form from the decomposition of this product. Do not store product at temperature in excess of 45°C (113°F) for extended periods of time, 1 week or more; or, using a heat source, such as steam, at a temperature in excess of 100°C (212°F).
Observe good industrial hygiene practices.
Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No special requirements under ordinary conditions of use and with adequate ventilation. Material should be handled in enclosed vessels and equipment, in which case general (mechanical) room ventilation should be sufficient. Local exhaust ventilation should be used at points where dust, mist, vapors or gases can escape into the room air.
Use nitrile or neoprene gloves. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm.
If contact is likely, safety glasses with side shields are recommended. Eye protection should meet the standards set out in EN 166.
A respiratory protection program compliant with all applicable regulations must be followed whenever workplace conditions require the use of a respirator. Under normal use conditions, respirator is not usually required. Use appropriate respiratory protection if exposure to dust particles, mist or vapors is likely. Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill clean-up sites. Use disposable dust/mist mask if the recommended exposure limit is exceeded. Use respirator with an organic vapor cartridge if exposure limit is exceeded. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment.
No data available. See section 6 for details.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
No data available.
Will not occur.
Do not expose to excessive heat, ignition sources, or oxidizing materials. Excessive heat.
Strong oxidizing agents. Strong mineral acids and strong oxidizing agents.
Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, nitrogen oxides, and other products of incomplete combustion.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations.
Dispose of packaging or containers in accordance with local, regional, national and international regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for B155454?
The signal word is no signal word.
What is the physical form of B155454?
B155454 is a liquid appearing as dark amber with dark amber color. It has characteristic odor.
What is the solubility of B155454?
No data available.
What is B155454 used for?
Passenger Car Oils
What are the hazard statements for B155454?
This substance has 1 hazard statement:
- H412: Harmful to aquatic life with long lasting effects.