NextSDS Logo
Safety Data Sheet EN

MARTOL EV 10 CF

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MARTOL EV 10 CF

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Metalworking fluid

Manufacturers & Suppliers

T

TotalEnergies Marketing Asia-Pacific Middle East Pte. Ltd.

regional supplier

182 Cecil Street, #27-01 Frasers Tower, Singapore 069547

+65 6879 2200

Emergency Contacts

Asia-Pacific

+65 3158 1074

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Asp. Tox. Cat. 1

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H304 May be fatal if swallowed and enters airways.

Precautionary Statements

P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER or doctor.
P331 Do NOT induce vomiting.
P405 Store locked up.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mineral oil of petroleum origin. Product containing mineral oil with less than 3% DMSO extract as measured by IP 346

Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C11-C12, isoalkanes, <2% aromatics 68551-17-7 50 - 75% No
Hydrocarbons, C11-C13, isoalkanes, <2% aromatics 90622-58-5 10 - 25% No
Hydrocarbons, C11-C14, isoalkanes, cyclics, <2% aromatics 64742-47-8 10 - 25% No

Mineral oil of petroleum origin. Product containing mineral oil with less than 3% DMSO extract as measured by IP 346

Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: No known significant effects or critical hazards.

Skin contact

Wash skin thoroughly with soap and water or use recognized skin cleanser. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms: Defatting to the skin. May cause skin dryness and irritation. Adverse symptoms may include the following: irritation, dryness, cracking.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention.

Symptoms: No known significant effects or critical hazards.

Ingestion

Wash out mouth with water. Remove dentures if any. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention if adverse health effects persist or are severe. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. The exposed person may need to be kept under medical surveillance for 48 hours.

Symptoms: May be fatal if swallowed and enters airways. Adverse symptoms may include the following: nausea or vomiting.

Immediate Medical Attention

Get medical attention if adverse health effects persist or are severe. The exposed person may need to be kept under medical surveillance for 48 hours.

Medical Treatment

Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use dry chemical, CO₂, water spray (fog) or foam.

Unsuitable media

Do not use water jet.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Avoid breathing vapor or mist. Provide adequate ventilation.

Small spill

Stop leak if without risk. Move containers from spill area. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container.

Materials: inert dry material, sand, earth, vermiculite or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Do not swallow. Avoid contact with eyes, skin and clothing. Avoid breathing vapor or mist. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.

Storage

Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Store locked up. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. Hydrocarbon-proof gloves, Fluorinated rubber, nitrile rubber. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid. [limpid]
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid. [limpid]
Colour
Colorless.
Colour Intensity
---
Form
---
Odor
Characteristic.
Odor Threshold
Not available.
Ph
Not applicable.
Melting Point
Technically not possible to measure
Boiling Point
184°C (363.2°F)
Flash Point
61°C (141.8°F)
Freezing Point
Technically not possible to measure
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
0.13 kPa (1 mm Hg)
Vapor Density
>1 [Air = 1]
Relative Density
0.75
Bulk Density
---
Density
0.75 g/cm³ [15°C]
Flammability
Not applicable.
Upper Explosive Limit
6.5%
Lower Explosive Limit
0.6%
Explosive Limits
---
Auto Ignition Temperature
200°C (392°F)
Decomposition Temperature
Not applicable.
Solubility
Not soluble
Partition Coefficient
Not applicable.
Solubility In Water
0.867 g/l
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
1.3 mm²/s (1.3 cSt)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage and handling conditions (see Section 7).

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.

Incompatible

No specific data.

Decomposition

carbon monoxide carbon dioxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
9003
Shipping Name
SUBSTANCES WITH A FLASH-POINT ABOVE 60 °C AND NOT MORE THAN 100 °C (Hydrocarbons, C11-C12, isoalkanes, <2% aromatics, Hydrocarbons, C11-C14, isoalkanes, cyclics, <2% aromatics)
Transport Class
9
ADR

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IMDG

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IATA

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The information stated in this section relates solely to the conformity of the chemical product with the countries Inventories. The information used to confirm the inventory status of this product may be based on additional data to the chemical composition shown in Section 3. Other regulations may apply for importation or marketing authorizations.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MARTOL EV 10 CF?

The signal word is danger.

What is the physical form of MARTOL EV 10 CF?

MARTOL EV 10 CF is a liquid. [limpid] appearing as liquid. [limpid] with colorless. color. It has characteristic. odor.

What is the solubility of MARTOL EV 10 CF?

Not soluble

What is MARTOL EV 10 CF used for?

Metalworking fluid

What are the hazard statements for MARTOL EV 10 CF?

This substance has 1 hazard statement:

  • H304: May be fatal if swallowed and enters airways.

What is the melting point of MARTOL EV 10 CF?

The melting point is Technically not possible to measure and the boiling point is 184°C (363.2°F).