NextSDS Logo
Safety Data Sheet EN

EROL 520 SX

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
EROL 520 SX
Product Form
Mixture

Regulatory Identifiers

CAS Number
N/A

Identified Uses

defoamer

Manufacturers & Suppliers

P

PMC OUVRIE

manufacturer

Rue Albert Einstein, 44, F-62220 CARVIN, France

+33 3 91.83.71.71

Emergency Contacts

ORFILA

+33.(0)1.45.42.59.59

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

This mixture does not contain any substances to be mentioned according to the criteria of section 3.2 of REACH Annex II

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Call a POISON CENTER/doctor. Allow affected person to breathe fresh air. Allow the victim to rest.

Skin contact

Take off immediately all contaminated clothing. Wash with plenty of water/...

Eye contact

Immediately flush eyes thoroughly with water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

Ingestion

Do NOT induce vomiting. Drink plenty of water. Immediately call a POISON CENTER/doctor. Rinse mouth.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide. Water spray.

Unsuitable media

Do not use a heavy water stream.

Specific hazards

Non-flammable product. Exercise caution when fighting any chemical fire.

Instructions

Evacuate area. Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire. Prevent fire fighting water from entering the environment.

Firefighter Protection

Do not enter fire area without proper protective equipment, including respiratory protection. Fire-fighters should wear appropriate protective equipment and a self-contained breathing apparatus with full facepiece operated in positive pressure mode.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate unnecessary personnel. Avoid contact with the product. Remove contaminated clothing immediately. Ventilate area.

Small spill

Small quantities of liquid spill: take up in non-combustible absorbent material and shovel into container for disposal. Soak up spills with inert solids, such as clay or diatomaceous earth as soon as possible. Collect spillage. Store away from other materials.

Environmental

Prevent entry to sewers and public waters. Avoid release to the environment.

Cleanup methods

Small quantities of liquid spill: take up in non-combustible absorbent material and shovel into container for disposal. Soak up spills with inert solids, such as clay or diatomaceous earth as soon as possible. Collect spillage. Store away from other materials.

Materials: non-combustible absorbent material, inert solids, such as clay or diatomaceous earth

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation.

Storage

Store in dry, cool, well-ventilated area. Protect from frost.

Hygiene

Do not eat, drink or smoke when using this product. Contaminated work clothing should not be allowed out of the workplace. Wash contaminated clothing before reuse.

Fire prevention

Keep away from open flame or sources of ignition - No smoking.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Assure a sufficient ventilation of the zones of storages and workplaces.

Hands

In case of repeated or prolonged contact wear gloves

Eyes

Chemical goggles or safety glasses

Respiratory

No special respiratory protection equipment is recommended under normal conditions of use with adequate ventilation

Skin/Body

Wear suitable protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor Threshold
Not available
Solubility In Fat
---
Colour Intensity
---
Decomposition Temperature
Not available
Odor
characteristic.
Auto Ignition Temperature
Not available
Melting Point
0 °C
Partition Coefficient
Not available
Explosive Limits
---
Appearance
Viscous.
Solidification Point
---
Properties Status
---
Ph
5
Upper Explosive Limit
Not available
Relative Evaporation Rate
---
Vapor Density
---
Softening Point
---
Solubility
In water, the material disperses.
Form
---
Voc Content
---
Flash Point
> 120 °C
Freezing Point
0 °C
State Under Standard Conditions
---
Kinematic Viscosity
Not available
Flammability
---
Cloud Point
---
Solubility In Water
---
Relative Density
1
Evaporation Rate
---
Vapor Pressure
Not available
Colour
White (Milk-like).
Physical State Data
liquid
Density
---
Lower Explosive Limit
Not available
Metal Corrosion
---
Bulk Density
---
Molecular Weight
---
Dynamic Viscosity
500 mPa·s 20°C
Crystallisation Point
---
Boiling Point
100 °C
Physical State
Liquid
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

No additional information available

Hazardous reactions

No polymerization.

Avoid

Extremely high or low temperatures.

Incompatible

Oxidizing agent.

Decomposition

In case of fire hazardous decomposition products may be produced such as: Carbon Monoxide, Carbon Dioxide (CO2).

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for EROL 520 SX?

The signal word is no signal word.

What is the physical form of EROL 520 SX?

EROL 520 SX is a liquid appearing as viscous. with white (milk-like). color. It has characteristic. odor.

What is the solubility of EROL 520 SX?

In water, the material disperses.

What is EROL 520 SX used for?

defoamer

What is the melting point of EROL 520 SX?

The melting point is 0 °C and the boiling point is 100 °C.