Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- EROL 520 SX
- Product Form
- Mixture
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
defoamer
Manufacturers & Suppliers
PMC OUVRIE
manufacturer
Rue Albert Einstein, 44, F-62220 CARVIN, France
+33 3 91.83.71.71
Emergency Contacts
ORFILA
+33.(0)1.45.42.59.59
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
This mixture does not contain any substances to be mentioned according to the criteria of section 3.2 of REACH Annex II
First Aid Measures
Emergency procedures for chemical exposure incidents
Call a POISON CENTER/doctor. Allow affected person to breathe fresh air. Allow the victim to rest.
Take off immediately all contaminated clothing. Wash with plenty of water/...
Immediately flush eyes thoroughly with water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Do NOT induce vomiting. Drink plenty of water. Immediately call a POISON CENTER/doctor. Rinse mouth.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide. Water spray.
Do not use a heavy water stream.
Non-flammable product. Exercise caution when fighting any chemical fire.
Evacuate area. Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire. Prevent fire fighting water from entering the environment.
Firefighter Protection
Do not enter fire area without proper protective equipment, including respiratory protection. Fire-fighters should wear appropriate protective equipment and a self-contained breathing apparatus with full facepiece operated in positive pressure mode.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate unnecessary personnel. Avoid contact with the product. Remove contaminated clothing immediately. Ventilate area.
Small quantities of liquid spill: take up in non-combustible absorbent material and shovel into container for disposal. Soak up spills with inert solids, such as clay or diatomaceous earth as soon as possible. Collect spillage. Store away from other materials.
Prevent entry to sewers and public waters. Avoid release to the environment.
Small quantities of liquid spill: take up in non-combustible absorbent material and shovel into container for disposal. Soak up spills with inert solids, such as clay or diatomaceous earth as soon as possible. Collect spillage. Store away from other materials.
Materials: non-combustible absorbent material, inert solids, such as clay or diatomaceous earth
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure good ventilation.
Store in dry, cool, well-ventilated area. Protect from frost.
Do not eat, drink or smoke when using this product. Contaminated work clothing should not be allowed out of the workplace. Wash contaminated clothing before reuse.
Keep away from open flame or sources of ignition - No smoking.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Assure a sufficient ventilation of the zones of storages and workplaces.
In case of repeated or prolonged contact wear gloves
Chemical goggles or safety glasses
No special respiratory protection equipment is recommended under normal conditions of use with adequate ventilation
Wear suitable protective clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No additional information available
No polymerization.
Extremely high or low temperatures.
Oxidizing agent.
In case of fire hazardous decomposition products may be produced such as: Carbon Monoxide, Carbon Dioxide (CO2).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for EROL 520 SX?
The signal word is no signal word.
What is the physical form of EROL 520 SX?
EROL 520 SX is a liquid appearing as viscous. with white (milk-like). color. It has characteristic. odor.
What is the solubility of EROL 520 SX?
In water, the material disperses.
What is EROL 520 SX used for?
defoamer
What is the melting point of EROL 520 SX?
The melting point is 0 °C and the boiling point is 100 °C.