Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- HiTEC® 312 Performance Additive
- Product Form
- Liquid
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Petrochemical industry: Extreme Pressure Agent
Manufacturers & Suppliers
Afton Chemical Limited
manufacturer
Euro-Tech Centre, London Road, Bracknell, RG12 2UW, England
+44 1344 304141
Afton Chemical S.R.L. (Woluwe)
manufacturer
Alma Court, Lenneke Marelaan, 8, B-1932, St-Stevens-Woluwe, Belgium
+32 2 715 2211
Afton Chemical S.R.L. (Feluy Plant)
manufacturer
Rue de Scoufflény, 50, B-7191 Ecaussinnes Lalaing, Belgium
+32 67 286211
Afton Chemical India PVT Ltd
manufacturer
Lotus Corporate Park, 7th Floor, A Wing, Ram Mandir Lane, Western Express Highway, Goregaon East, Mumbai 400063 India
+91 22 6728 0200
Emergency Contacts
Austria
+43 1 364 92 37
24 hours a day, 7 days a week
Belgium
+32 2 808 32 37
24 hours a day, 7 days a week
Bulgaria
+359 32 570 104
24 hours a day, 7 days a week
Croatia
+385 1 7776 920
24 hours a day, 7 days a week
Czech Republic
+420 228 880 039
24 hours a day, 7 days a week
Denmark
+45 69 91 85 73
24 hours a day, 7 days a week
Finland
+358 9 42725036
24 hours a day, 7 days a week
France
+33 9 75 18 14 07
24 hours a day, 7 days a week
Germany
0800 1817059
24 hours a day, 7 days a week
Greece
+30 21 1176 8478
24 hours a day, 7 days a week
Hungary
+36 1 808 8425
24 hours a day, 7 days a week
India
+91 8071 279 207
24 hours a day, 7 days a week
Ireland
+353 1 901 4670
24 hours a day, 7 days a week
Italy
+39 02 4555 7031
24 hours a day, 7 days a week
Luxembourg
+352 20 20 24 16
24 hours a day, 7 days a week
The Netherlands
+31 85 888 0596
24 hours a day, 7 days a week
Nigeria
+234 2012 278 883
24 hours a day, 7 days a week
Poland
+48 22 398 80 29
24 hours a day, 7 days a week
Portugal
+351 308 801 773
24 hours a day, 7 days a week
Slovakia
+421 2330 579 72
24 hours a day, 7 days a week
Slovenia
+386 1 888 80 16
24 hours a day, 7 days a week
South Africa
080 001 4676
24 hours a day, 7 days a week
Spain
+34 931 768 545
24 hours a day, 7 days a week
Swedish
+46 8 525 034 03
24 hours a day, 7 days a week
Switzerland
+41 435 082 011
24 hours a day, 7 days a week
United Kingdom
+44 20 3807 3798
24 hours a day, 7 days a week
International
+1 703 527 3887
24 hours a day, 7 days a week
EMEA
+44 20 3885 0382
24 hours a day, 7 days a week
Asia Pacific
+65 3163 8374
24 hours a day, 7 days a week
Central America
+55 55 8526 4930
24 hours a day, 7 days a week
South America
+55-11 4349 1359
24 hours a day, 7 days a week
US & Canada
+1 800 424 9300
24 hours a day, 7 days a week
Austria Poison Centre
+43 1 406 43 43
Belgium Poison Centre
+32 (0)70 245 245
Bulgaria Poison Centre
+359 2 9154 233
Croatia Poison Centre
+3851 2348 342
Cyprus Poison Centre
+357 1401
Czechia Poison Centre
+420 224 91 92 93
Denmark Poison Centre
+45 8212 1212
Estonia Poison Centre
+372 16662
France Poison Centre
+33 (0)1 45 42 59 59
Greece Poison Centre
+30 210 779 3777
Hungary Poison Centre
+36 80 201 199
Iceland Poison Centre
+354 112
Italy Poison Centre (Bergamo)
+39 800 883 300
Italy Poison Centre (Florence)
+39 055 794 7819
Italy Poison Centre (Foggia)
+39 800 183 459
Italy Poison Centre (Milan)
+39 02 6610 1029
Italy Poison Centre (Naples)
+39 081 545 3333
Italy Poison Centre (Pavia)
+39 0382 24444
Italy Poison Centre (Rome)
+39 06 305 4343
Italy Poison Centre (Rome)
+39 06 4997 8000
Italy Poison Centre (Rome)
+39 06 6859 3726
Italy Poison Centre (Verona)
+39 800 011 858
Latvia Poison Centre
+371 67042473
Lithuania Poison Centre
+370 (85) 236 2052
Luxembourg Poison Centre
+352 8002 5500
Netherlands Poison Centre
+31 (0)88 755 8000
Norway Poison Centre
+47 22 59 13 00
Portugal Poison Centre
+351 800 250 250
Romania Poison Centre
+40 (0)21 318 36 06
8am – 3pm
Slovakia Poison Centre
+421 2 5477 4166
Slovenia Poison Centre
+386 112
Spain Poison Centre
+34 91 562 04 20
Sweden Poison Centre
+46 112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
The mineral oils in the product contain < 3% DMSO extract (IP 346).
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1-Propene, 2-methyl-, sulfurized EC: 270-943-2 | 68511-50-2 | 100% | Yes |
The EC substance definition and related classification & labelling have been developed in the framework of the regulation (EC) No. 1907/2006 (REACH). The related CAS number (*) is used for the purposes of the international inventories present in Section 15 of the SDS. Please note some GHS hazard classifications listed above may not be applicable in your country or region and are shown for informational purposes only.
Notes
The mineral oils in the product contain < 3% DMSO extract (IP 346).
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing.
Symptoms: No specific data.
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Symptoms: No specific data.
Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention if irritation occurs.
Symptoms: No specific data.
Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention if adverse health effects persist or are severe. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms: No specific data.
Immediate Medical Attention
Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In case of fire, use water spray (fog), foam, dry chemical or CO₂.
Do not use water jet.
In a fire or if heated, a pressure increase will occur and the container may burst. This material may cause long lasting harmful effects to aquatic life. Fire water contaminated with this material must be contained and prevented from being discharged to any waterway, sewer or drain.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
For non-emergency personnel: Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment. For emergency responders: If specialized clothing is required to deal with the spillage, take note of any information in Section 8 on suitable and unsuitable materials.
Stop leak if without risk. Move containers from spill area. Absorb with an inert material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilled product. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Absorb with an inert material and place in an appropriate waste disposal container.
Materials: inert material, non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
HiTEC® 312 Performance Additive
---
HiTEC® 312 Performance Additive
---
HiTEC® 611 Performance Additive
UFI: P23V-M161-F00E-3XJR
HiTEC® 340 Performance Additive
UFI: FFRA-A9AQ-HT21-VCP5
HiTEC® 11320 Performance Additive
---
HiTEC® 343 Performance Additive
UFI: P3KE-NQVK-QF2U-0VT1
HiTEC® 321 Performance Additive
UFI: Y033-K7D3-551A-TMJ2
HiTEC® 11183 Performance Additive
UFI: DCJS-J0GD-G00F-WY7Y
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Warning! Headspace of storage vessel may contain hydrogen sulfide. Put on appropriate personal protective equipment (see Section 8). Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing vapor or mist. Avoid release to the environment. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.
Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors below their respective threshold limit value.
Wear chemical resistant gloves. Nitrile gloves of minimum thickness 0.4 mm have an expected breakthrough time of 480 minutes or less when in frequent contact with the product. Due to variable exposure conditions the user must consider that the practical use of a chemical-protective glove in practice may be much shorter than the permeation time above. Manufacturer's directions for use, especially about the minimum thickness and the minimum breakthrough time, must be observed. This information does not replace suitability tests by the end user since glove protection varies depending on the conditions under which the product is used.
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.
Use appropriate respiratory protection if there is the potential to exceed the exposure limit(s). Seek professional advice prior to respirator selection and use. Select respirator based on suitability to provide adequate worker protection for given working conditions and level of airborne contaminant.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
High temperatures, sparks and open flames.
Strong oxidizing and reducing agents.
Hydrogen sulfide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for HiTEC® 312 Performance Additive?
The signal word is no signal word.
What is the physical form of HiTEC® 312 Performance Additive?
HiTEC® 312 Performance Additive is a liquid. [clear.] appearing as liquid. [clear.] with yellow. to amber. color. It has pungent. odor.
What is the solubility of HiTEC® 312 Performance Additive?
Not soluble
What is HiTEC® 312 Performance Additive used for?
Petrochemical industry: Extreme Pressure Agent
What are the hazard statements for HiTEC® 312 Performance Additive?
This substance has 1 hazard statement:
- H413: May cause long lasting harmful effects to aquatic life.
What is the melting point of HiTEC® 312 Performance Additive?
The melting point is Not available. and the boiling point is Not available..