NextSDS Logo
Safety Data Sheet EN

HiTEC® 312 Performance Additive

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
HiTEC® 312 Performance Additive

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Petrochemical industry: Extreme Pressure Agent

Manufacturers & Suppliers

A

Afton Chemical Corporation

manufacturer

500 Spring St., Richmond, VA 23219, USA

+1-804-788-5800

A

Afton Chemical Canada Corporation

manufacturer

5045 South Service Road, Suite 101, Burlington, ON L7L 5Y7

905-631-5470

Emergency Contacts

Emergency Contact

0800-70-77-022

Emergency Contact

800-681-9531

Emergency Contact

+1-703-527-3887

Emergency Contact

+1-703-741-5979

Emergency Contact

+1-800-424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Flam. Liq. Cat. 4

GHS Pictograms

Hazard Statements

Combustible liquid.

Precautionary Statements

P210 Keep away from flames and hot surfaces. - No smoking.
P235 Keep cool.
P280 Wear protective gloves.
P282 Wear eye or face protection.
P370 + P378 In case of fire, use water spray (fog), foam, dry chemical or CO₂.
P403 Store in a well-ventilated place.
P501 Dispose of contents and container in accordance with all local, regional, national and international regulations.
Avoid breathing vapor.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
1-Propene, 2-methyl-, sulfurized 68511-50-2 100% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. If not breathing, give artificial respiration. If breathing is difficult, administer oxygen.

Symptoms: No known significant effects or critical hazards. No specific data.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms: No known significant effects or critical hazards. No specific data.

Eye contact

Immediately flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention if irritation occurs.

Symptoms: No known significant effects or critical hazards. No specific data.

Ingestion

Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention if adverse health effects persist or are severe. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms: No known significant effects or critical hazards. No specific data.

Immediate Medical Attention

Get medical attention if irritation occurs. Get medical attention if adverse health effects persist or are severe. Get medical attention if symptoms occur. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

In case of fire, use water spray (fog), foam, dry chemical or CO₂.

Unsuitable media

Do not use water jet.

Specific hazards

Combustible liquid. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion. Runoff to sewer may create fire or explosion hazard.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Put on appropriate personal protective equipment.

Small spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.

Large spill

Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor.

Environmental

Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Wash spillages into an effluent treatment plant.

Materials: non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Do not ingest. Avoid contact with eyes, skin and clothing. Avoid breathing vapor or mist. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Empty containers retain product residue and can be hazardous. Do not reuse container.

Storage

Store in accordance with local regulations. Store in a segregated and approved area. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Eliminate all ignition sources. Separate from oxidizing materials. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

Hands

Hand Protection: Wear chemical resistant gloves. Nitrile gloves of minimum thickness 0.4 mm have an expected breakthrough time of 480 minutes or less when in frequent contact with the product. Due to variable exposure conditions the user must consider that the practical use of a chemical-protective glove in practice may be much shorter than the permeation time above. Manufacturer's directions for use, especially about the minimum thickness and the minimum breakthrough time, must be observed. This information does not replace suitability tests by the end user since glove protection varies depending on the conditions under which the product is used.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Liquid. [Clear.]
Colour
Yellow. to Amber.
Colour Intensity
---
Form
---
Odor
Pungent.
Odor Threshold
Not available.
Ph
Not available.
Melting Point
Not available.
Boiling Point
Not available.
Flash Point
Closed cup: 80°C (176°F) [Pensky-Martens Minimum]
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
Not available.
Vapor Density
Not available.
Relative Density
1.135
Bulk Density
---
Density
1.133 g/cm³ [59°F (15°C)]
Flammability
Not available.
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
---
Partition Coefficient
Not applicable.
Solubility In Water
Not soluble
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Kinematic (40°C (104°F)): 59 mm²/s (59 cSt) Minimum 8 cSt at 100°C
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable.

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

Under normal conditions of storage and use, hazardous reactions will not occur.

Avoid

Avoid all possible sources of ignition (spark or flame). Do not pressurize, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition.

Incompatible

Reactive or incompatible with the following materials: oxidizing materials

Decomposition

Hydrogen sulfide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Toxicity

Product/ingredient name | Result | Species | Exposure | Remarks | 1-Propene, 2-methyl-, sulfurized | Acute EL50 >100 mg/l | Algae - Pseudokirchneriella subcapitata | 72 hours | No effects at saturation. | | Acute EL50 >1000 mg/l | Daphnia - Daphnia magna | 48 hours | No effects at saturation. | | Acute LL50 10000 mg/l | Fish - Cyprinodon variegatus | 96 hours | - | | Chronic NOEL 5 mg/l | Algae - Pseudokirchneriella subcapitata | 72 hours | No effects at saturation.

Persistence and degradability

1-Propene, 2-methyl-, sulfurized | OECD 301B Ready Biodegradability - CO2 Evolution Test | 0.3 % - Not readily - 28 days | -

Bioaccumulative potential

Not available.

Not available.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.

Disposal

Dispose of surplus and non-recyclable products via a licensed waste disposal contractor.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
NA1993
Shipping Name
Combustible liquid, n. o.s. (Sulfurized olefins)
Transport Class
Combustible liquid
Packing Group
III
ADR

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IMDG

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

IATA

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

All components are listed or exempted in most international inventories. For Europe, Switzerland, Turkey, and the UK, contact the Afton representative for compliance information.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for HiTEC® 312 Performance Additive?

The signal word is warning.

What is the physical form of HiTEC® 312 Performance Additive?

HiTEC® 312 Performance Additive is a liquid. appearing as liquid. [clear.] with yellow. to amber. color. It has pungent. odor.

What is HiTEC® 312 Performance Additive used for?

Petrochemical industry: Extreme Pressure Agent

What are the hazard statements for HiTEC® 312 Performance Additive?

This substance has 1 hazard statement:

  • Combustible liquid.

What is the melting point of HiTEC® 312 Performance Additive?

The melting point is Not available. and the boiling point is Not available..