01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
INDOPOL® H-25, H-25 SR, H-50, H-100, H-100 CP, H-300, H-300 C, H-300 CP, H-1200, H1200 CP
Product Form
Liquid.
Product Code
SDS#: 0000000011
Chemical Name
Polybutene (Isobutylene/butene copolymer)
Synonyms
Not available.

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Not available. Consumer applications, Industrial applications, Professional applications.

Manufacturers & Suppliers

I

Ineos Singapore Pte. Ltd.

national supplier

111, Somerset Road #14-16 to 21, TripleOne Somerset Singapore 238164

+65 6513 2348

Emergency Contacts

Alert SGS

+65 6542-9595

24 hr

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

No known significant effects or critical hazards.

Precautionary Statements

Not applicable.
Not applicable.
Not applicable.
Not applicable.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Chemical identity : Polybutene (Isobutylene/butene copolymer)

Chemical Name CAS Number Concentration Hazardous
Polybutene (Isobutylene/butene copolymer) 9003-29-6 100% No

The inventory status and regulatory information shown here are based on CAS number 9003-29-6. This material may also be described by CAS number 9044-17-1.

Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section. Occupational exposure limits, if available, are listed in Section 8.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get immediate medical advice/attention.

Symptoms: Exposure to aerosols or particulates from heated material may cause adverse lung effects if high concentrations are inhaled.

Skin contact

Hot material: Immediately flush with cool water for at least 15 minutes. Get immediate medical attention. Cold material: Clean exposed skin with waterless hand cleaner.

Symptoms: Prolonged or repeated contact can defat the skin and lead to irritation, cracking and/or dermatitis. Heated material can cause thermal burns.

Eye contact

Hot material: Flush eyes with plenty of water for at least 15 minutes. Seek medical assistance for mechanical removal of this material from the eye. The use of flushing fluid, other than water, is not recommended. Cold material: flush eyes with plenty of water.

Symptoms: May cause slight transient irritation. Heated material can cause thermal burns.

Ingestion

Do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. Wash out mouth with water. Call physician immediately.

Symptoms: Ingestion may cause gastrointestinal irritation and diarrhoea.

Immediate Medical Attention

Get immediate medical advice/attention for inhalation exposure. Get immediate medical attention for hot skin contact. Call physician immediately for ingestion.

Medical Treatment

No specific treatment.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

In case of fire, use water spray (fog), foam, dry chemical or CO₂.

Unsuitable media

Do not use water jet.

Specific hazards

Rapid depolymerisation can occur in a fire and produce flammable vapours. May depolymerise at temperatures above 200°C with the production of extremely flammable butene monomers. Vapour may cause fire. Vapours may accumulate in low or confined areas or travel a considerable distance to a source of ignition and flash back. Runoff to sewer may create fire or explosion hazard.

Instructions

Where open cell insulation has been contaminated with polybutene, spontaneous combustion may occur at temperatures as low as 138°C (280°F). Therefore, where open cell insulation has been used, the temperature of storage tanks and heat tracing must be kept well below 120°C (250°F) and any insulation contaminated with polybutene should be replaced immediately.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Do not breathe vapour or spray. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put on appropriate personal protective equipment.

Small spill

For small spills, add absorbent (soil may be used in the absence of other suitable materials) and use a non-sparking or explosion-proof means to transfer material to a sealable, appropriate container for disposal.

Large spill

For large spills, dyke spilt material or otherwise contain material to ensure runoff does not reach a waterway. Place spilt material in an appropriate container for disposal. Avoid contact of spilt material and runoff with soil and surface waterways. Treat as an oil spill. See section 13 for waste disposal information.

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air).

Cleanup methods

add absorbent and use a non-sparking or explosion-proof means to transfer material to a sealable, appropriate container for disposal; Place spilt material in an appropriate container for disposal.

Materials: absorbent (soil may be used in the absence of other suitable materials)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8). Do not get in eyes or on skin or clothing. Do not breathe vapour or mist. Do not ingest. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Empty containers retain product residue and can be hazardous. Do not reuse container.

Storage

Store in a segregated and approved area. A potentially flammable atmosphere may be generated if material is held hot for prolonged periods. For prolonged storage at temperatures of 60°C and above, keep in rust-free tanks and exclude oxygen by use of a nitrogen blanket. Heating systems which generate localised hot spots should never be used. Suitable storage materials are: mild steel / carbon steel. Store and use away from heat, sparks, open flame or any other ignition source. Keep container in a cool, well-ventilated area. Keep container tightly closed and sealed until ready for use.

Hygiene

Eating, drinking and smoking should be prohibited in area where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

Fire prevention

Store and use away from heat, sparks, open flame or any other ignition source.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special ventilation requirements. Good general ventilation should be sufficient to control worker exposure to airborne contaminants. If this product contains ingredients with exposure limits, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure below any recommended or statutory limits.

Hands

Wear gloves that cannot be penetrated by chemicals or oil. Nitrile rubber. When handling hot material, wear heat resistant protective gloves, clothing and face shield that are able to withstand the temperature of the heated product. The correct choice of protective gloves depends upon the chemicals being handled, the conditions of work and use, and the condition of the gloves (even the best chemically resistant glove will break down after repeated chemical exposures). Most gloves provide only a short time of protection before they must be discarded and replaced. Because specific work environments and material handling practices vary, safety procedures should be developed for each intended application. Gloves should therefore be chosen in consultation with the supplier/manufacturer and with a full assessment of the working conditions.

Eyes

Safety glasses with side shields. Goggles, face shield or other full-face protection should be worn if there is a risk of direct exposure to aerosols or splashes or when material is handled hot.

Respiratory

If ventilation is inadequate, use respirator that will protect against organic vapour and dust/mist.

Skin/Body

Wear apron or coverall if there is a risk of exposure to splashes. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Odor
Characteristic.
Molecular Weight
---
Decomposition Temperature
May depolymerise at temperatures above 200°C with the production of extremely flammable butene monomers.
Explosive Limits
---
Boiling Point
Polymer that decomposes before reaching a boiling point.
Metal Corrosion
---
Dynamic Viscosity
---
Density
---
Solidification Point
---
Physical State
Liquid.
Solubility In Water
---
Appearance
---
Crystallisation Point
---
Solubility
None.
Colour Intensity
---
Physical State Data
liquid
Vapor Pressure
<0.1 kPa [room temperature]
Freezing Point
---
Softening Point
---
Ph
Not available.
Form
---
Melting Point
Not available.
Voc Content
---
Colour
Clear. Colourless.
Odor Threshold
Not available.
Flammability
Not applicable.
Kinematic Viscosity
>500 mm²/s (>500 cSt)
Evaporation Rate
Not available.
Properties Status
---
Solubility In Fat
---
Cloud Point
---
Flash Point
Closed cup: >125 to <190°C (>257 to <374°F) [Pensky-Martens.]. Open cup: >150 to <250°C (>302 to <482°F) [Cleveland.]
State Under Standard Conditions
---
Bulk Density
---
Vapor Density
Not available.
Upper Explosive Limit
Not available.
Auto Ignition Temperature
Not available.
Partition Coefficient
Not available.
Lower Explosive Limit
Not available.
Relative Evaporation Rate
---
Relative Density
0.869 to 0.906
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage and handling conditions (see Section 7).

Reactivity

No specific test data related to reactivity available for this product or its ingredients.

Hazardous reactions

May depolymerise at temperatures above 200°C with the production of extremely flammable butene monomers.

Avoid

Keep away from all sources of ignition, heat, sparks, flame. Avoid strong oxidising conditions. Avoid extended exposure to temperatures above 60°C in the presence of air.

Incompatible

Strong oxidizing agents; acidic clays at >100C.

Decomposition

Under normal conditions of storage and use, hazardous decomposition products should not be produced.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN3257
Shipping Name
ELEVATED TEMPERATURE LIQUID, N.O.S. (Polybutene)
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is INDOPOL® H-25, H-25 SR, H-50, H-100, H-100 CP, H-300, H-300 C, H-300 CP, H-1200, H1200 CP known by?

INDOPOL® H-25, H-25 SR, H-50, H-100, H-100 CP, H-300, H-300 C, H-300 CP, H-1200, H1200 CP is also known as: Not available.

What is the hazard signal word for INDOPOL® H-25, H-25 SR, H-50, H-100, H-100 CP, H-300, H-300 C, H-300 CP, H-1200, H1200 CP?

The signal word is no signal word.

What is the physical form of INDOPOL® H-25, H-25 SR, H-50, H-100, H-100 CP, H-300, H-300 C, H-300 CP, H-1200, H1200 CP?

INDOPOL® H-25, H-25 SR, H-50, H-100, H-100 CP, H-300, H-300 C, H-300 CP, H-1200, H1200 CP is a liquid. with clear. colourless. color. It has characteristic. odor.

What is the solubility of INDOPOL® H-25, H-25 SR, H-50, H-100, H-100 CP, H-300, H-300 C, H-300 CP, H-1200, H1200 CP?

None.

What is INDOPOL® H-25, H-25 SR, H-50, H-100, H-100 CP, H-300, H-300 C, H-300 CP, H-1200, H1200 CP used for?

Not available. Consumer applications, Industrial applications, Professional applications.

What are the hazard statements for INDOPOL® H-25, H-25 SR, H-50, H-100, H-100 CP, H-300, H-300 C, H-300 CP, H-1200, H1200 CP?

This substance has 1 hazard statement:

  • No known significant effects or critical hazards.

What is the melting point of INDOPOL® H-25, H-25 SR, H-50, H-100, H-100 CP, H-300, H-300 C, H-300 CP, H-1200, H1200 CP?

The melting point is Not available. and the boiling point is Polymer that decomposes before reaching a boiling point..

Compliance Scanner

Scan your compliance