Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ENERPAC HF-95X, HF-95Y, HF-95Z, HF-95T, HF-95200
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Hydraulic oil.
Manufacturers & Suppliers
Maskin K. Lund AS
distributor
Stålfjæra 11, Postboks 21 Kalbakken, N-0901 OSLO
+47 22 90 02 00
http://www.mkl.no
Emergency Contacts
Giftinformasjonen
+47 22 59 13 00
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Notes
The product contains: Highly refined mineral oil and additives. The oil contains <3% DMSO-extract. This indicates that the ingredient is not carcinogenic.
First Aid Measures
Emergency procedures for chemical exposure incidents
Fresh air and rest.
Symptoms: May cause respiratory irritation.
Remove contaminated clothing. Wash the skin immediately with soap and water. Get medical attention if any discomfort continues.
Symptoms: The product may irritate skin and cause itching, burning and redness. The product dehydrates the skin on prolonged or repeated contact.
Immediately flush with plenty of water for up to 15 minutes. Remove any contact lenses and open eyes wide apart. By prolonged rinsing, use lukewarm water to avoid damage to the eye. Contact physician if discomfort continues.
Symptoms: Sprut og damp kan gi svie i øynene.
Give some cream or vegetable oil. Do not induce vomiting. Seek medical advice.
Symptoms: May cause nausea, vomiting and diarrhea.
Immediate Medical Attention
Get medical attention if any discomfort continues.
Medical Treatment
No specific treatment required, see section 4.1.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Foam, carbon dioxide or dry powder.
Do not use water jet.
The product is not classified as flammable. Combustible at high temperatures.
Containers close to fire should be removed immediately or cooled with water.
Firefighter Protection
Use fresh air equipment when the product is involved in fire. In case of evacuation, an approved protection mask should be used. See also section 8.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use protective equipment as referred to in section 8. Provide adequate ventilation.
Do not allow to enter into sewer, water system or soil.
Collect in suitable containers and deliver as hazardous waste according to section 13. Beware of slippery floors and surfaces.
Materials: suitable containers
Related Products
Similar products with comparable safety profiles
HF-95X, HF-95Y, HF-95Z
---
INDOPOL® H-25, H-25 SR, H-50, H-100, H-100 CP, H-300, H-300 C, H-300 CP, H-1200, H1200 CP
CAS: 9003-29-6, 9044-17-1
INDOPOL® H-25, H-25 SR, H-50, H-100, H-100 CP, H-300, H-300 C, H-300 CP, H-1200, H1200 CP
---
INDOPOL® H-1500, H-1900, H-2100, H-6000, H-18000
---
RADIACID 0970H
CAS: 61788-89-4
RADIACID 0950
CAS: 61788-89-4
SPETEC STOP HF300 (Highfoamer)
---
LC10EC, LC12EC, LC15EC, LC101C, LC103C, LC105C, LC110C, LC111C, LC113C, LC115C, LC121C, LC123C, LC125XLC, LC131C, LC133C, LC135XLC, LC161C, LC163C, LC505C, LC525XLC, LC535XLC, LC545XLC, LC563C, LC565XLC, LC583C, LC585XLC, LC595XLC
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with skin and eyes. Use work methods which minimise oil mist production. Contaminated rags and cloths must be put in fireproof containers for disposal.
Store in a cool, well-ventilated place. Store in tightly closed container.
Wash hands after contact with the product. Change contaminated clothing and take off protective equipment before the meal. Do not smoke, drink or eat in the workplace.
Keep away from heat, sparks and open flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate ventilation.
Use chemical resistant gloves. Suitable gloves type: Nitrile. Breakthrough time: Penetration time is not known. The recommended material of gloves is recommended after a study of the single components in the product.
Wear safety goggles if there is a risk of splash.
Normally not required. In case of inadequate ventilation or risk of inhalation of oil mist, suitable respiratory equipment with combination filter (type A2/P3) can be used.
Ordinary workwear.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable under normal conditions of storage and use.
Under normal conditions and use there is not expected any reactivity hazards for this product.
None under normal conditions. Arise in contact with inappropriate conditions and incompatible materials (sections 10.4 and 10.5)
Avoid heat, flames and other sources of ignition.
Strong oxidizing agents.
None under normal conditions. See also section 5.2.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ENERPAC HF-95X, HF-95Y, HF-95Z, HF-95T, HF-95200?
The signal word is no signal word.
What is the physical form of ENERPAC HF-95X, HF-95Y, HF-95Z, HF-95T, HF-95200?
ENERPAC HF-95X, HF-95Y, HF-95Z, HF-95T, HF-95200 is a fluid. with blue. color. It has oil smell. odor.
What is ENERPAC HF-95X, HF-95Y, HF-95Z, HF-95T, HF-95200 used for?
Hydraulic oil.
What is the melting point of ENERPAC HF-95X, HF-95Y, HF-95Z, HF-95T, HF-95200?
The melting point is Not entered. and the boiling point is Not entered..