NextSDS Logo
Safety Data Sheet EN

Ethylene glycol ≥99 %, for synthesis

CAS 107-21-1
EC 203-473-3

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Ethylene glycol ≥99 %, for synthesis
Product Code
9516
Chemical Name
Ethylene glycol
Synonyms
Ethanediol

Regulatory Identifiers

CAS Number
107-21-1 Check regulations →
EC Number
203-473-3 Check regulations →
REACH No.
01-2119456816-28-xxxx

Identified Uses

Laboratory chemical Laboratory and analytical use Formulation [mixing] of preparations and/or re-packaging (excluding alloys) Industrial uses Professional uses

Uses advised against

Do not use for products which come into contact with foodstuffs. Do not use for private purposes (household). Food, drink and animal feeding-stuffs.

Manufacturers & Suppliers

Carl Roth GmbH + Co. KG logo

Carl Roth GmbH + Co. KG

national supplier

Schoemperlenstr. 3-5 D-76185 Karlsruhe Germany

+49 (0) 721 - 56 06 0

www.carlroth.de

Emergency Contacts

National Poisons Information Centre Beaumont Hospital

+353 1 809 2166

EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Acute Tox. Cat. 4 H302
STOT RE Cat. 2 H373

GHS Pictograms

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H302 Harmful if swallowed
H373 May cause damage to organs (kidney) through prolonged or repeated exposure (if swallowed)

Precautionary Statements

P260 Do not breathe mist/vapours
P270 Do not eat, drink or smoke when using this product
P301 + P312 IF SWALLOWED: Call a POISON CENTER or doctor if you feel unwell

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Ethylene glycol EC: 203-473-3 107-21-1 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Provide fresh air. In all cases of doubt, or when symptoms persist, seek medical advice.

Skin contact

Rinse skin with water/shower. In all cases of doubt, or when symptoms persist, seek medical advice.

Eye contact

Rinse cautiously with water for several minutes. In all cases of doubt, or when symptoms persist, seek medical advice.

Ingestion

Rinse mouth with water (only if the person is conscious). Call a doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

water spray, alcohol resistant foam, dry extinguishing powder, BC-powder, carbon dioxide (CO₂)

Unsuitable media

water jet

Specific hazards

Combustible. Vapours are heavier than air, spread along floors and form explosive mixtures with air.

Instructions

co-ordinate firefighting measures to the fire surroundings! Fight fire with normal precautions from a reasonable distance.

Firefighter Protection

In case of fire and/or explosion do not breathe fumes. Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Keep away from drains, surface and ground water. Retain contaminated washing water and dispose of it.

Cleanup methods

Absorb with liquid-binding material (sand, diatomaceous earth, acid- or universal binding agents).

Materials: sand, diatomaceous earth, acid- or universal binding agents

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Provision of sufficient ventilation.

Storage

Keep container tightly closed. Store in a dry place. Hygroscopic.

Hygiene

Wash hands before breaks and after work. Keep away from food, drink and animal feedingstuffs.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Wear suitable gloves. Chemical protection gloves are suitable, which are tested according to EN 374. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. The times are approximate values from measurements at 22 °C and permanent contact. Increased temperatures due to heated substances, body heat etc. and a reduction of the effective layer thickness by stretching can lead to a considerable reduction of the breakthrough time. If in doubt, contact manufacturer. At an approx. 1.5 times larger / smaller layer thickness, the respective breakthrough time is doubled / halved. The data apply only to the pure substance. When transferred to substance mixtures, they may only be considered as a guide. Type of material: NBR (Nitrile rubber). Material thickness: >0,3 mm. Breakthrough times of the glove material: >480 minutes (permeation: level 6).

Eyes

Use safety goggle with side protection.

Respiratory

Respiratory protection necessary at: Aerosol or mist formation. Type: A (against organic gases and vapours with a boiling point of > 65 °C, colour code: Brown).

Environmental

Keep away from drains, surface and ground water.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
colourless - light yellow
Colour Intensity
---
Form
---
Odor
odourless
Odor Threshold
---
Ph
6 – 7,5 (in aqueous solution: 100 g/l, 20 °C)
Melting Point
-14 – -12 °C
Boiling Point
197 – 198 °C
Flash Point
111 °C
Freezing Point
-14 – -12 °C
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
0,12 hPa at 25 °C
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1,11 g/cm³ at 20 °C
Flammability
this material is combustible, but will not ignite readily
Upper Explosive Limit
43 vol%
Lower Explosive Limit
3,2 vol%
Explosive Limits
---
Auto Ignition Temperature
412 °C
Decomposition Temperature
not relevant
Solubility
---
Partition Coefficient
-1,36
Solubility In Water
1.000 g/l at 20 °C
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
16 – 18 mPa s at 25 °C
Kinematic Viscosity
not determined
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The material is stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.

Reactivity

This material is not reactive under normal ambient conditions. If heated Vapours may form explosive mixtures with air.

Hazardous reactions

Exothermic reaction with: Sulphuric acid, Alkali hydroxide (caustic alkali), Aluminium, Nitric acid, Risk of ignition: Chlorates, Permanganates, Peroxides, strong oxidiser

Avoid

Protect from moisture. Keep away from heat.

Incompatible

aluminium, zinc

Decomposition

Hazardous combustion products: see section 5.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
not assigned
Packing Group
not assigned
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Ethylene glycol ≥99 %, for synthesis known by?

Ethylene glycol ≥99 %, for synthesis is also known as: Ethanediol

What is the hazard signal word for Ethylene glycol ≥99 %, for synthesis?

The signal word is warning.

What is the physical form of Ethylene glycol ≥99 %, for synthesis?

Ethylene glycol ≥99 %, for synthesis is a liquid with colourless - light yellow color. It has odourless odor.

What is Ethylene glycol ≥99 %, for synthesis used for?

Laboratory chemical Laboratory and analytical use Formulation [mixing] of preparations and/or re-packaging (excluding alloys) Industrial uses Professional uses

What are the hazard statements for Ethylene glycol ≥99 %, for synthesis?

This substance has 2 hazard statements:

  • H302: Harmful if swallowed
  • H373: May cause damage to organs (kidney) through prolonged or repeated exposure (if swallowed)

What is the melting point of Ethylene glycol ≥99 %, for synthesis?

The melting point is -14 – -12 °C and the boiling point is 197 – 198 °C.

Compliance Scanner

Scan your compliance